DOTmed.com
New and Used Medical Equipment For Sale and Wanted
We don't own it... We help you sell it.
My DOTmed
Login | Register
October 7, 2008
Post a Listing
Post an Auction
DOTmed 2009 Buyer's Guide
Get a Free Listing
Listing #300905 For Sale TOPCON CT 80 Auto NCT Tonometer / Tono-Pen
This Premium Listing has been seen 47 times and clicked on 41 times (as of 05:00 am edt)
TOPCON CT 80 Auto NCT Tonometer / Tono-Pen for sale
Updated: September 19, 2008
Condition: Excellent
The TOPCON CT-80 takes its original measurement method using two sensors; one for light and one for pressure.When the air puff applanates the cornea a light sensor detects the applanation moment, while at the same time another sensor monitors the internal chamber to obtain the intraocular pressure. Triple Safety Function A Focus on Safety The CT-80 features an innovative triple safety function. First, an adjustable safety stopper may be set by the operator.Second, a "too close" display on the monitor guides the user in alignment. Third, an audible warning buzzer informs the operator if the cornea and the instrument are too close. 30% Faster Interval Time Fast and Easy Measurements The CT-80 provides easier and faster operation with the aid of a new alignment bar and an improved air cylinder. The interval between measurements has been reduced by over 30%, so that patients may be examined more comfortably in a shorter period of time. Once the alignment has been completed, the resulting data are automatically measured and displayed. Built-in Self Check Function The CT-80 lets the operator know in advance when maintenance is needed. It displays a warning message on the monitor when a lens is dirty, and also which lens it is (the measurement glass or the chamber glass). Model CT-80 Measurement Range 0 - 60mmHg [0 - 30mmHg/0 - 60mmHg (Selectable)] Working Distance 11mm Measurement Display TV Monitor Screen *R / L change over --- automatically detected and displayed. *Up to three measurement of each eye can be displayed and printed out. Measurement Recording Built-in printer Measurement Mode Auto / Manual (selectable) Alignment When the alignment luminous spots are within the inner alignment mark, * In Auto Mode : measurement is automaticaly activated * In Manual Mode : alignment will change from a broken box to a solid pattern when proper alignment is achieved, and depressing the switch on the omni-directional joystick activates the measuring cycle. Error Indication When the measurement signal is not strong enough, IOP value is indication in ( ) or just 'ERR' is displayed. Adjustable Safety Stopper Minimum distance between the front of the instrument and the patient can be established in advance. Operating Temperature 10°C to 40°C Base Travel 44mm (back & forth) / 88mm (left & right) / 28mm (vertically) Chinrest Vertical Travel 68mm External Output Terminal RS-232C Power Supply AC100 - 120V, 220 - 240V, 50 / 60Hz Power Consumption 80VA ("Auto-shut-off" : power saving mechanism adopted) Dimensions 272(W) × 505(D) × 430 - 458(H)mm Weight Approx. 18kg



 Lister

DOTmed's COMPLIANCE NOTICE AND COMPLIANCE COMPLAINT PROCEDURE.

Access and use of this site is subject to the terms and conditions of our LEGAL NOTICE & PRIVACY NOTICE
Property of and Proprietary to DOTmed.com, Inc.
Copyright ©2001-2008 DOTmed.com, Inc.
ALL RIGHTS RESERVED