DOTmed.com
New and Used Medical Equipment For Sale and Wanted
We don't own it... We help you sell it.
My DOTmed
Login | Register
October 12, 2008
Post a Listing
Post an Auction
DOTmed 2009 Buyer's Guide
Get a Free Listing
Listing #534842 For Sale DATASCOPE 5L Monitor
This Premium Listing has been seen 22 times and clicked on 117 times (as of 12:00 pm edt)
DATASCOPE 5L Monitor for sale       
Updated: September 22, 2008
Asking Price: $1,199.00 USD
Condition: Good
SN:P55090-K6
Dimension: 9.5" x 13" x 8" (H x W x L)
Weight: 13 lbs. maximum without batteries
Power Consumption: 15 watts typical
Voltage input: 100, 120, 220, 240 VAC ± 10%
Mains frequency: 47 to 65 Hz
ECG

Leads: I, II, III
Display sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0 cm/mV ± 10%
Frequency response to screen: ESU filter out: 0.5 to 40 Hz, -3db max @ 1 mVpp input; ESU filter in: 0.5 to 20 Hz -3db max @ 1 mVpp input
Heart Rate Meter

Range: 30-300 bpm adult/child. 30-350 bpm neonatal
Accuracy: 30-250 bpm ± 3bpm or 3%, whichever is greater.
Pacer rejection: rejects all pulse of amplitude ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with no tail. Rejects all pulses ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with 100 ms T.C. tail <0.8 mV or 25 ms T.C. tail <0.4 mV.
Display update: 2 seconds ± 0.1 sec
NIBP

Technique: oscillometric
Systolic range: adult/ped mode: 40-250 mmHg, neonate mode: 15-150 mmHg.
Diastolic range: adult/ped mode: 30-200 mmHg, neonate mode: 10-150 mmHg.
Systolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 3 mmHg, standard deviation less than 13 mmHg (neonatal).
Diastolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 4 mmHg, standard deviation less than 7 mmHg (neonatal).
Heart rate meter range: 30-250 bpm.
Heart rate meter accuracy: ±3 bpm or ±3%, whichever is greater.
Pulse Oximetry

Accuracy (1standard deviation): 70-100%, ±2%; 60-69%, ±4%; 0-59%, unspecified.
Response time: 13 seconds to 95% of final step change % SpO2 value from 60-95% at 72 bpm
Recorder (optional)

Speed: 50, 25, 12.5, 6.25, 3.125 mm/sec ±5%
Note: 6.25 and 3.125 are for respiration only
Chart size: 50 mm ±2mm
Battery Requirements

ML



 Lister

CARLOS VARGAS INCAV
Phone: +1 408-275-8202Country: USA
Click here to visit INCAV's Webstore

DOTmed's COMPLIANCE NOTICE AND COMPLIANCE COMPLAINT PROCEDURE.

Access and use of this site is subject to the terms and conditions of our LEGAL NOTICE & PRIVACY NOTICE
Property of and Proprietary to DOTmed.com, Inc.
Copyright ©2001-2008 DOTmed.com, Inc.