DOTmed Auctions > No. 4833 : FISCHER SenoScan Mammo Unit
Esta é uma tradução automática gerada máquina e é fornecida como uma referência somente. DOTmed não autoriza sua exatidão, e DOTmed não é responsável para nenhuns erros da tradução. Se você tiver qualquer pergunta a respeito do termo ou meaning do texto traduzido, veja por favor a versão inglesa. Os controles da versão do inglês no evento de algum conflito.
This is a machine generated automatic translation and is provided as a reference only. DOTmed does not warrant its accuracy, and DOTmed is not responsible for any translation errors. If you have any question regarding the term or meaning of the translated text, please view the English version. The English version controls in event of any conflict.
|
|
|
|
Começar oferecida: U.S.$50000.00
- Reserva não encontrada com
Este artigo não será vendido se o preço de reserva não for encontrado com.
Tempo saiu:
Auction Closed
Posição:
TX,
USA
A oferta fecha-se: May 28 - 2:00pm EST
Fabricante: FISCHER
Modelo: SenoScan
|
|
|
|
| O que você está oferecendo sobre: |
You are bidding on a 2004 Fischer SenoScan:
Has two 5 megapixel flat monitor.
This unit was installed in 2005.
2005 SenoScan Enterprise Digital Acquisition System:
-SenoScan Trueview digital mammography scanning system is designed to perform screening and digital magnification diagnostic mammography procedures.
DICOM MG Output of SenoScan Acquired Images:
-Open Architecture Allows for Integration with a Network or PACS
-Inter-connectivity with any Fischer approved Softcopy Review Work Station or any FDA 510(k) cleared PACS workstation for diagnostic read of digital mammograms Includes Client Server and Administrative Workstation
SenoScan Gantry:
-0.3 mm, 8 kW, 4-Inch (102 mm) Rotating Anode Tungsten/Rhenium X-Ray Tube includes Heat Unit Exchanger for high capacity patient throughput
-Telescopic Elevating Column
-Motorized Elevation
-Motorized or Manual Gantry Rotation
-LED Display of Angle
-2x Dual Footswitch for Motorized Compression/Rotation/Elevation
-Rapid Release Paddle De-Compression
-Rapid Speed -Gantry Rotation
-Operator Radiation shield
-Carbon Fiber Breast Support
-Paddle Set Provided
-Compression Paddle (24 x 30 cm)
-High Resolution Paddle (10 x 15 cm)
-Spot Compression Paddle (5 x 7 cm)
-Removable Recessed Patient Face Shield
SenoScan High Resolution Detector:
-CCD Slot Scan Detector
-Active Detector Area-10-mm X 210-mm
-4096 x 5625 Matrix Size
-Single Button Selection of Field of View (FOV)
-21cm x 29cm FOV 50 Micron Pixel- Screening Mode -10 1p/mm Spatial Resolution
-11cm x 15cm FOV 25m Micron Pixel- Diagnostic Mode -14 1p/mm Spatial Resolution
SenoScan Acquisition Work Station (AWS):
-High Performance CPU
-Minimum of 40 GB Hard Disk
-Radiation Shield: 190 cm x 40 cm (75 in x 28 in) -19" Flat Panel Color Monitor on Pivot Mount for User Selectable Viewing Position
-1.79 GB Dimm Memory
-SenoScan Application Software
-Security Log-on (User Name/Password) -Automatic Technique Recommendation (ATR) -User Definable Software Workflow Protocols/Attributes -Keyboard/Mouse
-100 Base T Ethernet Network Interface
SenoScan CLIENT SERVER AND ADMINISTRATIVE WORKSTATION (105473G):
-High Speed Server with Capacity for up to 3 SenoScan Gantries to a single RWS
-Image File Server (including Image Processing) -Patient File (DB) Server -Dual Mirrored 72 GB Hard Drive (56 GB Useable) -4GB Dimm Memory
-DICOM Output
-DICOM Store and Query/Retrieve (94184) (DICOM Store Service Class User (SCU) for the SenoScan Digital Scanning
Mammography System. This feature provides the ability to store SenoScan Studies
to a DICOM Store- Service Class Provider (SCP) archive). Requires a validated
DICOM Store-Service Class Provider (SCP) archive, which is NOT included in
this pricing. PACS archive provider may require additional interface charges.
-ICOM Modality Worklist and DICOM Print are Optional.
SenoScan Operator (P-55943-OM):
-Single Phase- Manuel English
Single-Phase Generator (105289G):
-8 kw
-20-45 kvp
-80-220 Ma
-Single-phase 240 vac, 50-60 Hz (standard)
SENOLINK REMOTE DIAGNOSTICS VPN #105246; MODEM #105250G
SenoScan OPEN GRID NEDDLE LOCALIZATION PADDLE:
-18 cm x 24 cm-3,14 inches wide x 1.57 deep (.16 inches from front edge)-x
axis: Letters (A-J- y axis: Numbers (0-4)
DICOM PRINT (94189):
If this interface is to an existing printer, the printer manufacturer may levy additional interface charges. These charges are the responsibility of the customer.
SenoScan issues Print Management requests to a remote SCP supporting the DICOM V3.0 Print Services, in order to produce hard copy representations of DICOM images. SenoScan transfers DICOM images to a Print Services SCP upon request from the SenoScan user. When an image is to be printed, SenoScan initiates the negotiation of an associatin with the requested Print Services SCP. If
the association is accepted, the images are transferred from the SenoScan SCU
application to the Print Services SCP over that association. Once the transfer is complete, SenoScan releases tha association
DICOM MODALITY WORKLIST (94309):
A HIS/RIS gateway (i.e. PAC'S broker is required. FIC does not provide this gateway. Please consult with your IT department of HIS/RISprovider regarding gateway.
SenoScan imports a DICOM Modality Worklist from a HIS/RIS system.
SenoScan initiates an association with HIS/RIS system SCP. This funtionality will deliver patient deomographics to the SenoScan acquisition workstation upon completion of the study. The HIS/RIS system is notified at the completion of the study.
DOCUMENTATION PACKAGE:
Operator and Service Manual SECTRA Breast Imaging Workstation (Standalone) MW0300: The SECTRA Breast Imaging Workstation is appropriate for installations comprising either one or two Mammography Workstations that will utilize an existing PACS image server/archive. It may be combined with one additional Breast Imaging Review Station (MW0200)
MWO300 includes:
-SECTRA Clincal Edition PACS package and software license -SECTRA File System Archive Software
-DICOM Modality Worklist Service Software -IDS5/MX Breast Imaging Workstation Software -Dell Precision 670 Workstation with keyboard and mouse -3GB DDR memory
-292 GB Fast SCSI Disk Storage
-3,5 in., 1.44 MB Floppy
-CD-R/RW Drive
-Gigabit Ethernet Interface Card
-Samsung 19" Color Flat Panel Display
-Display card with Direct X Drivers
-Sectra Workflow-Plus Keypad
-Screen Calibrator Unit
Image Server XD DICOM Storage Service MW0305:
-Automates transmission of user created annotations and reports to PACS.
- There are two 5 Megapixel Flat monitor |
| Circunstância: |
O equipamento é instalado e operacional, está no uso clínico e é coberto atualmente por um contrato de serviço. |
| Inspeção: |
Você está livre inspecionar este equipamento mas se você quiser inspecionar por favor o equipamento faz assim que antes que você ofereça. Se você gostar de arranjar para inspecionar este equipamento estale sobre do “o Seller email” acima.
O equipamento é ficado situado em Texas.
|
| Disponível: |
O equipamento estará disponível imediatamente em cima do recibo do pagamento completamente. |
| Garantia: |
Este equipamento é oferecido de acordo com o “Auction denomina” e “observação legal” de www.dotmed.com. Nenhuma garantia é expressada ou implicada, including toda a garantia do merchantability ou da aptidão para uma finalidade particular. Todo o equipamento é vendido “como é” e “onde está”.
. |
| Serviços adicionais: |
Esta unidade foi prestada serviços de manutenção por um coordenador ex-Fischer. Este coordenador pode fornecer o deinstallation e a instalação com a despesa adicional do custo e de curso. |
| Termos: |
O licitante bem sucedido concorda remitir completamente o pagamento dentro de 48 horas do fim do Auction.
Se o licitante bem sucedido não remitir o pagamento de acordo com a programação descrita acima, o equipamento estará vendido então ao licitante o mais elevado seguinte.
Deinstallation, a embalagem, o Crating e o transporte serão pagados pelo licitante bem sucedido.
O título transferirá do Seller ao licitante bem sucedido em cima do pagamento completamente. |
This Auction is CLOSED. |
Bid History
| Bidder |
Bid Date |
Quantity |
Bid Amount |
|
| This item will not be sold if the Reserve price is not met. |
Questions about this auction
There have been no questions regarding this auction yet.
Ask a question.
DOTmed's COMPLIANCE NOTICE AND COMPLIANCE COMPLAINT PROCEDURE.