Used RIGHTON Retinomax 3 Autorefractor For Sale - DOTmed Listing #2361160:

Clean Sweep Live Auction on Thur. Dec. 12th. Click to view the full inventory

RIGHTON Retinomax 3 Autorefractor for sale RIGHTON Retinomax 3 Autorefractor for sale RIGHTON Retinomax 3 Autorefractor for sale RIGHTON Retinomax 3 Autorefractor for sale RIGHTON Retinomax 3 Autorefractor for sale
RIGHTON Retinomax 3 Autorefractor for sale RIGHTON Retinomax 3 Autorefractor for sale RIGHTON Retinomax 3 Autorefractor for sale RIGHTON Retinomax 3 Autorefractor for sale RIGHTON Retinomax 3 Autorefractor for sale

For Sale RIGHTON Retinomax 3 Autorefractor

  • Asking Price :$7,500.00 USD
  • Condition : Used - Good
  • Est. Shipping(US) : $120.00 USD
  • Weight : 45.00 Lbs
  • Qty. Available : 1
  • In Stock : Yes
  • Date : December 09, 2019
  • credit-card
  • credit-card
  • credit-card
  • credit-card

Item Description

Seller assumes all responsibility for this listing.

Listing: #2361160

  • Condition: Used - Good
  • Brand: RIGHTON
  • Type: Autorefractor
  • Model: Retinomax 3
  • Warranty: 90 days
This used Retinomax Autorefractor has been checked and certified by an authorized. Perfect cosmetic and working condition with 90 days warranty. We have the Autorefractor and Keratometer models.

Product Description

What’s included with the Retinomax Autorefractor

Used Handheld Autorefractor Retinomax 3
Printer
Charger Unit
Instruction Manual
Metallic Case
----------------------------------------------------------------

Handheld Autorefractor Retinomax 3 Specifications

Much Lighter and has a thinner grip

Weighing just under one kg, the main body with battery is over 17% lighter in the case of the Retinomax Autorefractor K-plus 3 and 11% lighter in the case of the Retinomax 3 than conventional Retinomax Series models.

The Retinomax Series 3’s center of gravity is in the grip, making if feel much lighter than it actually is.

Auto Quick measurement

If no measurement is made within six seconds, the unit automatically enters Quick mode.

Measurement is then taken in 0.07 seconds. In Auto Quick model, “AQ” appears on printouts.

Parallel sensor detects inclination of main body and displays value

Unlike conventional methods, in which operators guess levelness, levelness can be detected digitally with the use of the unit’s parallel sensor.

Levelness is displayed on the monitor in every 2 deg pitch up to 12 degrees, and every 3 deg pitch up to 45 deg. (This is only displayed in the standing position.

No levelness display appears when the patient is lying down.)

Auto pupil measurement, display and printout

The Retinomax Autorefractor unit measures pupil size automatically, displays the X (horizontal) size on the monitor, and prints out the XY (horizontal and vertical) sizes separately.

These results can be used as reference for checking accommodation, mydriasis, ADIE and Horner-associated syndrome, etc.

The user can choose to print out either all the data or representative values only.

Alignment indicator display

Indicators showing alignment directions are displayed on the monitor to facilitate alignment. The Mire ring makes focusing much easier in the Retinomax autorefractor.

Two memory functions

Data from the last measurement is automatically saved after the Retinomax 3 is turned off. The last patient data can be recalled by pressing the PRINT key. The data can be transferred wirelessly to a printer.
Press the MEMORY key for more than one second to enter Memory Set. Here you can save the data of up to 50 patients (100 eyes) in 10, 20, 30 and 40 patient steps. Data can also be printed out with Memory Set. For measurements, first press the MEMORY key to enter Memory mode. After each measurement, press PRINT to save individual patient data. This avoids the possibility of single-eye readings being mixed up. In normal readings, numbers are assigned in series. However, in Memory mode, saved data is numbered from “1”.
Achieving long and continuous use

With the adoption of a lithium ion battery, continuous operational time has been extended to approximately 80 minutes. The Retinomax autorefractor station has an AC adapter, allowing it to be connected to the main body with a DC cord (optional) to enable extended continuous operation. This facilitates screening, as well as use in an operating room.

Fixation intensity is automatically lowered for pupils less than 3 mm in size

The minimum pupil measurement size in Auto Quick mode is 2.3 mm. If a pupil is less than 3.0 mm, the fixation target intensity is automatically reduced by 45% to avoid pupil contraction. The intensity can also be reduced with the fixation intensity key.

Extended diopter adjustment range

The diopter adjustment range has been extended to +-8D

Quick startup and fast printout

The main body takes only four seconds to start after power is turned on (60% faster than conventional models). Printout time has been reduced by 45%

Retinomax 3 retro illumination mode

The Retinomax 3 includes the retro illumination mode for observation of the inside of the pupil. Accordingly, the only major difference between the Retinomax 3 and the Retinomax K-Plus 3 is the adoption of kerato functions (including peripheral kerato readings).

Return Policy

Returns All equipment sales are FINAL, no item can be returned without approval by returns department and must contain RMA #. If an item is approved for a return it will be assessed a 20% restocking fee, unless it’s due to factory defect and then fee will not be assessed. Factory evaluation is necessary prior to fee being waived. Buyer has 3 working days from receipt of equipment for claims of shortage or damage of any kind. Claims must be made in writing and in the event of damage; buyer must retain any and all packaging with the equipment for inspection. Failure to retain the packaging will void your rights to relief occurring as a result of transport damages. No returns are allowed after 15 (fifteen) days of receiving the order for any reason. Special orders, custom fabrication and similar service are non-refundable and non-returnable for any reason. All returns if approved must be returned to us prepaid and in good conditions. Any deficiencies in the return item due to normal wear, neglect, abuse, shipping damages, etc. are the responsibility of the buyer and deductions for repair will be assessed. The Buyer authorizes Digital Eye Center. to charge the purchaser’s credit card for restocking fees, travel expenses and any other assessed charges from deficiencies as set forth in this paragraph. All approved refunds will be charged back to the same method of payment within 10 business days after approved the refund. All equipment unless otherwise noted are FOB Miami, FL Unless otherwise noted payment is due at time of placement of order. Costs for overdue accounts sent for collections and/or enforcement of the terms of sale, including legal collection service etc. are the responsibility of the buyer and governing law for all transactions with Digital Eye Center will be construed and interpreted in the state of Florida.