For Sale: SIEMENS Biograph 16 PET/CT

Seller Info
Xavier Lanier
Mobile Imaging of America
Phone: (800) 431-4065
Country: USA

Suggested Price: $60,000 USD
Condition: Good
Siemens Biograph 16 PET/CT Hi Rez The Siemens Biograph 16 Hi Rez is a whole-body CT scanner ideal for oncological imaging and diagnosis. The Siemens Biograph 16 produces excellent images, inherently registered, that show detailed anatomy and biological processes at the molecular level, with just one noninvasive procedure. The Siemens Biograph 16 features LSO detector design, exceptional imaging quality, 16-slice CT detectors, a spacious gantry for flexible patient positioning, higher definition imaging with PET HI-REZ, the syngo multimodality computer system, as well as a small footprint for easy siting. Features of the Siemens Biograph 16 PET/CT 70 cm gantry aperture and unique reinforced cantilever designs 50 cm CT Transverse FOV LSO Detector Technology 4.5 ns coincidence window Static and multibed acquisition modes 100s spiral scan times Specifications Patient Handling System Width: 42 cm (16 in) Length: 379 cm (149 in) Weight: 693 kg (1528 lb) Maximum Patient Weight: 204 kg (449 lb) Horizontal Scan Range (Head First): 156 cm (61.4 in) Horizontal Scan Range (Feet First): 182 cm (71.1 in) Horizontal Bed Travel: 269.5 cm (106 in) Vertical Bed Travel: 53 – 107 cm (20-42 in) ACPlus: Standard Detector Assembly Detector Material Lutetium: Oxyorthosilicate (LSO) Crystal Dimensions: 4.0 x 4.0 x 20 mm Crystal’s Per Detector Block: 169 Number of Detector Blocks: 144 Photomultiplier Tubes (PMTs): 4 per block Detector Ring Diameter: 830 mm Detectors Per Ring: 624 Number of Detector Rings: 24 Total Number of Detectors: 24336 Transaxial Field of View: 585 mm Axial Field of View: 162 mm Number of Image Planes: 81 Plane Spacing: 2 mm CT Volume Aquisition Max. No. of CT slices 16 Number of detector rows 24 Elements 16128 Channels per slice 1344 Number of projections up to 2320 (1/360 CT Transverse Scan Field 50 cm CT Rotation times 0.42, 0.5, 0.75, 1.0, 1.5s CT Temporal resolution down to 105 ms Tube Assembly Maximum generator power 60kW Tube DURA Akron Q Tube current 28 – 500 mA Tube voltages 80, 120, 140 kV Tube anode heat storage capacity: 5.3 MHU Focal spot size according to IEC 60 336: 0.5 x 0.7 mml7 and 0.8 x 1.2 mml7 Image Quality Low-Contrast Detectability: Technique: 20 cm Ø Catphan 120 kV, 0.75 s, 10 mm)?Spiral 5 mm / 3 HU / 19 mGy+ at 180 mAs ?Sequence 5 mm / 3 HU / 20 mGy+ at 190 mAs ?High-Contrast Resolution (Technique: 150 mA/ 120 kV, 0.75 s, 1mm) 0% MTF ± 10% 30 lp/cm 0.17 mm, 2% MTF ± 10% 24 lp/cm 0.21 mm
Updated: June 12, 2026