We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.
If you have a broken Sonosite, Mindray, GE, Philips, Hitachi, or Aloka system or probe contact us today. Free ultrasound & probe EVALS with 1 Year Warranty on all repairs. We repair all orders in 1-5 days. Call 844-644-5440 Email: Sales@Lenard.Healthcare
Faulty Phenomenon Description of the problem: when connecting both sensors of the RAB6-RS, an error appears in the Motor Control Unit. Troubleshooting and Solutions Description of the problem:... view more
Faulty Phenomenon Replacement of the acoustic lens (photo before replacement, inside the post - after... view more
Faulty Phenomenon Restoration of the sealing of the piston (problem: leakage of oil was detected under the piston). Troubleshooting and Solutions Restoration of the bellows seal (problem: an oil... view more
Faulty Phenomenon Malfunction: During the examination, artifacts appear in the form of bright spots, morgania, etc. With each examination, the artifacts increase. Solution: The malfunction was... view more
Faulty Phenomenon Malfunction: when turning on, an error appears, associated with overheating of the device solution: the TO of the device was performed, and the MRX192 board was also repaired. ... view more
Faulty Phenomenon Malfunction: Based on the results of the service testing, the board BF192 (5357234-20) is faulty. The malfunctioning channel has been identified as the cause of the device's... view more
Faulty Phenomenon Malfunction: when turning on, a net image is displayed on the screen instead of the "dynamic circles" image, and non-existent sensors are also reflected. Replaced faulty... view more
Faulty Phenomenon A stripe appeared on the display of the RST board (PN: KTZ196358, KTZ280122). RST - impulse transmission board, 16 pieces are installed in the device (1 faulty). Sent the board... view more
Faulty Phenomenon GE Logiq E10: A malfunction was detected in the TX board, an element that controls the switching on/off of high voltage for supply to the acoustic module has failed. The device is... view more
Faulty Phenomenon Malfunction: error 607 indicates a malfunction in the data base solution: after restarting the PO device, it worked. Troubleshooting and Solutions Malfunction: error 607... view more
Faulty Phenomenon Malfunction: During the examination, echo-imaging disappears and everything turns into white color. Solution: repair RFM323 plate. Troubleshooting and Solutions Malfunction:... view more
Faulty Phenomenon Malfunction: during operation, a blue screen appears on the device. Sometimes the device does not turn on and the power button flashes yellow. Solution: repair the power supply... view more
Faulty Phenomenon Malfunction: during operation of the device, a break occurred and an error Error on Power management (error in the power supply block) appeared. Solution: repair the RFM and RSX... view more
Faulty Phenomenon Repair platform MRX192 (PN: 5393908) of Logiq E9 R6. Malfunction: the image quality has deteriorated, artifacts appeared on all transducers. Troubleshooting and Solutions Repair... view more
Faulty Phenomenon Repair platform MRX192 (PN: 5393908) of Logiq E9 R6. Malfunction: the image quality has deteriorated, artifacts appeared on all transducers. Troubleshooting and Solutions Repair... view more