Faulty Phenomenon Malfunction: during operation, a blue screen appears on the device. Sometimes the device does not turn on and the power button flashes yellow. Solution: repair the power supply... view more
Faulty Phenomenon Malfunction: during operation of the device, a break occurred and an error Error on Power management (error in the power supply block) appeared. Solution: repair the RFM and RSX... view more
Faulty Phenomenon Repair platform MRX192 (PN: 5393908) of Logiq E9 R6. Malfunction: the image quality has deteriorated, artifacts appeared on all transducers. Troubleshooting and Solutions Repair... view more
Faulty Phenomenon Repair platform MRX192 (PN: 5393908) of Logiq E9 R6. Malfunction: the image quality has deteriorated, artifacts appeared on all transducers. Troubleshooting and Solutions Repair... view more
Faulty Phenomenon Repair flat panel DBM128G Assy (PN: 5773602). Malfunction: during operation with the sensor on the display artifacts or interference of white color appear. Troubleshooting and... view more
Faulty Phenomenon Repair block of power supply Main Power Supply (PN: 5205054). Malfunction: absence of 48V for the computer power supply block and therefore the device does not turn on. ... view more
Faulty Phenomenon Repair the Main Power Supply (PN: GA200730-5) power supply block. Malfunction: when turning on the device, it shows the error "System Error". The logs indicated that the ultrasound... view more
Faulty Phenomenon Repair flatbed RFM323 (PN: RFM304073, RFM304141) (also used in versions BT17, BT19, BT20, BT21) malfunction: when turning on, the image begins to intensely display white noise... view more
Faulty Phenomenon Repair flat RSR14, RSR19 (PN: KTZ196357, KTZ196310) and RST15, RST20 (PN: KTZ196358, KTZ280122) malfunction: when turning on, the image begins to intensively display white noise... view more
Faulty Phenomenon Repair the Main Power Supply (PN: 5205052-7) power supply block. This power supply unit is also suitable for Vivid E9. Malfunction: does not turn on the device, no 48 V on the... view more
Faulty Phenomenon Repair of electronic volume transducer GE eM6C malfunction: error code (ASIC thermal info error 0x10A6), began to issue an error due to overheating, the cause of which is the... view more
Faulty Phenomenon Repair RFM423 (PN: KTZ304074) of the GE Voluson E10 (versions BT17, BT18, BT19, BT20, BT21) device. Malfunction: when turning on the probe, the image begins to display intense... view more
Faulty Phenomenon Repair flat panel DBM128G ASSY (PN:5573638-2) from GE Voluson S10 BT18. Malfunction: when turning on the device, the image begins to intensively display white noise across the... view more
Faulty Phenomenon LOGIQ P5 has no response at startup. Troubleshooting and Solutions GE LOGIQ P5 Repair: Solved No Power/No Startup Issue 🔋 The Problem The LOGIQ P5 system showed no... view more
Faulty Phenomenon GE LOGIQ P9 Ultrasound Repair: Fixed Image Dark Line Issue Troubleshooting and Solutions GE LOGIQ P9 Ultrasound Repair: Fixed Image Dark Line Issue ⚡ Problem Reported A... view more