Sysmex RD-100i One Step Nucleic Acid Analyser Detector OSNA CK19 mRNA RT-Lamp
In Good Condition And Full Working Order
Included:-
1 x Sysmex RD-100i One Step Nucleic Acid Analyser Detector OSNA CK19 mRNA RT-Lamp
1 x HP Monitor
1 x HP RP5800 i3 3.3GHz PC - Preloaded with RD Software
1 x Keyboard & Mouse
1 x HP LaserJet 1320 Printer
1 x Sysmex RD-100i Stand
1 x Sysmex Test Protocol Manual
1 x Sysmex RD-100i Software User Guide
1 x Set of Setup Software DVD
The test procedure
The lymph node tissue is homogenised in one simple step prior to analysis. Further filtration of the RNA is not required. The samples are then processed and measured under standardised conditions in the RD-100i, an automated real time analyser. Up to four lymph nodes (up to 8 samples for colon cancer) can be analysed in parallel. The results are available in approximately 30 minutes.
The device features a 16-minute amplification reaction in real time. Depending on the number of measured copies of the mRNA marker, the results are shown in one of three categories:
(++) = Indication for a macrometastatic tumour burden
(+) = Indication for a micrometastatic tumour burden
(–) = No metastatic disease
Advantages of the OSNA® method:
Simple sample processing
Isothermal reaction at 65°C
Very fast amplification reaction (16 minutes)
Indication of the size of the metastatic lesions
Technical specifications
Instrument - Gene Amplification Detector System RD-100i
Method - OSNA® (One Step Nucleic Acid Amplification)
Parameter - CK19 mRNA
Technology - RT-LAMP (Reverse transcriptase loop-mediated isothermal amplification)
Detection - Change of transmitted light caused by the precipitation of magnesium
pyrophosphate depending on the grade of the reaction
Displayed parameters - CK19 Q (CK19 Qualitative Result)
CK19 (CK19 Risetime)
CK19 C (CK19 mRNA-concentration)
Throughput - 4 samples per batch
Tissue range per sample - 50–600 mg
Sample volume - 2 μL
Reagents - homogenising reagent LYNORHAG
amplification reagent LYNOAMP BC
all reagents are ready for use
Data storage - 2000 samples
Quality control - positive and negative control
180 data points per file
Interfaces - Host computer connection (RS232, LAN)
printer connection (USB)
Weight - approx. 66 kg
Dimensions (W x H x D) - 596 x 548 x 622 mm
Return Policy
180 Day Return Policy. Customer must pay the return shipping costs when returning a product.
All items are sold in good working condition with a 6 month warranty as standard. Please ask for extended warranty options.
SaveOnKit will pay return shipping on all faulty items.