The Alfa Wassermann Ace Alera system is the proven, high-performance, low-maintenance chemistry analyzer capable of improving patient care and your bottom line.
The Alfa Wasserman Ace Alera clinical chemistry system serves a wide variety of chemistry diagnostic needs with the power of a large floor model analyzer in an easily integrated and economizing compact footprint of a bench-top model.
Alfa Wassermann Ace Alera Instrument Features:
The Alfa Wassermann Ace Alera is productive:
The Alfa Wassermann Ace Alera processes up to 165 photometric tests per hour and up to 120 potentiometric (ISE) tests per hour.
The Alfa Wassermann Ace Alera has closed tube sampling:
The Alfa Wassermann Ace Alera system's patented closed tube sampling assures safety by effectively minimizing the risk of blood borne pathogens. There's no need to pour off samples.
The Alfa Wassermann Ace Alera offers on-board sample and reagent refrigeration:
The Alfa Wassermann Ace Alera’s refrigerated compartment maintains specimen and reagent integrity as well as eliminating overnight reagent transfer. Up to 40 test reagents can be stored on-board at any time.
The Alfa Wassermann Ace Alera has positive sample and reagent ID:
The Alfa Wassermann Ace Alera’s software identifies and tracks samples, patients and reagent details including expiration date and remaining reagent. Stores up to 1,000 patient records and 5,000 requisitions.
The Alfa Wassermann Ace Alera offers stat interrupt:
The Alfa Wassermann Ace Alera offers a unique STAT interrupt process for single or panel testing.
The Alfa Wassermann Ace Alera offers auto repeat and dilution:
The Alfa Wassermann Ace Alera system ensures fast, accurate reporting of abnormal test results by automatically diluting and repeating those tests without operator intervention while offering a unique STAT test interrupt process for single tests.
Alfa Wassermann Ace Alera Technical Specification
General
Alfa Wassermann Ace Alera Start-up time: 15 minutes from power-up
Alfa Wassermann Ace Alera Analysis Types: Spectrophotometric, Potentiometric (optional)
Alfa Wassermann Ace Alera Assay Types: Final Point, Delta (two-point) Slope (factor or calibrated) Quadratic
Alfa Wassermann Ace Alera Throughput: Up to 165 results/hour
Alfa Wassermann Ace Alera STAT Turnaround Time: Between 1 and 15 minutes depending on test(s) ordered
Alfa Wassermann Ace Alera Calibration Frequency:
Optical: Monthly sample delay and optical calibration.
Photometric: Test dependent (refer to package insert)
Potentiometric: Automatic every three hours
Alfa Wassermann Ace Alera Analytical Temperature: 37º C ± 0.3ºC
Alfa Wassermann Ace Alera Ambient Room Temperature: 15ºC (59°F) to 32ºC (89.6°F)
Alfa Wassermann Ace Alera Humidity: 20 to 80% RH (non-condensing)
Alfa Wassermann Ace Alera Maximum Cuvette Capacity: 248
Alfa Wassermann Ace Alera Power Rating:
Analyzer: 100-240VAG, 47/63 HZ, 6Amps Max.
ACE Alera Nominal: 450 Watts Max (Analyzer only)
Printer: 120 or 240VAC, 66 Watts Idle
340 Watts Operating
700 Watts Peak
Sample Delivery
Alfa Wassermann Ace Alera Presentation to System: Closed or open tube
Sample cups individually
Sample cups in groups of up to 15 on cup segment
Alfa Wassermann Ace Alera Segment Capacity: Five in combination (cup and/or well)
Alfa Wassermann Ace Alera Tube Size for Direct Sampling: 75 to 100 mm length; 13 to 16 mm diameter
Alfa Wassermann Ace Alera Stopper Styles: Rubber stopper, VACUT AINER with Hemogard Closure or stopperless.
Alfa Wassermann Ace Alera Fill Volume Required for Tube sampling: Between 0.9 inches and 2.23 inches from top of glass tube
Alfa Wassermann Ace Alera Serum Volume Required for Tube Sampling: Minimum 0.5 inches above clot or separator
Alfa Wassermann Ace Alera Sample Capacity: 75-150 samples
15 sample cups/cup segment
30 samples wells/well segment
Alfa Wassermann Ace Alera Sample ID: Positive ID by optional barcode or requisition match for closed or open tubes Loadlist or requisition match for sample cups
Alfa Wassermann Ace Alera Barcode Type: Uniform Symbology Specification 39, Code 128 Set B and Set C, Codabar and Interleaved 2 of 5
Alfa Wassermann Ace Alera Barcode Placement Zone: Within the range of 0.09 inches and 2.35 inches from top of glass tubes with a maximum of 5° skew (slant)
Alfa Wassermann Ace Alera Sample Delivery Capacity: 3-200uL in 1uL increments
Alfa Wassermann Ace Alera Typical Volumes Used: 3-2uL
Alfa Wassermann Ace Alera Sample Dead Volume: 90uL per seglet
Alfa Wassermann Ace Alera Sample Delivery Precision: Less than 5% CV at 3uL
Alfa Wassermann Ace Alera Level Detection: Automatic with liquid level sensor
Alfa Wassermann Ace Alera Sample Integrity: 2 or 4 hours onboard working lifetime clock (2 or 4 can be selected on the setup analyzer screen)
Reagent Delivery
Alfa Wassermann Ace Alera Reagent Compartment Capacity: 40 bottles 20 with 30mL capacity 20 with 12mL capacity
Alfa Wassermann Ace Alera Reagent Compartment Temperature: 8ºC ± 1ºC at the reagent sensor
Alfa Wassermann Ace Alera Reagent ID: Positive ID by computer coded labels on bottom of bottles
Alfa Wassermann Ace Alera Reagent Delivery Capacity: 3-500uL in 1uL increments
Alfa Wassermann Ace Alera Reagent Delivery Precision: Less than 0.5% CV
Alfa Wassermann Ace Alera Level Detection: Automatic with liquid level sensor
Alfa Wassermann Ace Alera Reagent Integrity: Onboard working lifetime clock
Optical System
Alfa Wassermann Ace Alera Absorbance Measurement Type: Holographic diffraction grating
Linear Range: 0.0000-2.0000 O.D. at 0.67 cm pathlength
Wavelengths: 340,378, 408,447, 486,505, 515,525,544,554,573,592,
610, 629, 647, 692 nm
Alfa Wassermann Ace Alera Lamp: Pulsed Xenon
Alfa Wassermann Ace Alera Path length: 0.67cm
Alfa Wassermann Ace Alera Cuvette Volume: 150-600uL
Alfa Wassermann Analysis Cycle: 10 seconds
Potentiometric System
Alfa Wassermann Ace Alera Sample Type: serum
Alfa Wassermann Ace Alera Assay Volume: 156uL (a minimum of 206uL required in cup to accommodate probe depth and dead volume)
Alfa Wassermann Ace Alera Analytes Measured: Sodium, Potassium & Chloride
Alfa Wassermann Ace Alera Analysis Cycle: 90 seconds
Computer Processor IBM-compatible PC®
Alfa Wassermann Ace Alera RAM Memory: 32MB
Alfa Wassermann Ace Alera Graphics Adaptor: Color SVGA compatible
Alfa Wassermann Ace Alera External Disk Drive: 3.5 in., 1.44MB
Alfa Wassermann Ace Alera Hard Disk Drive: 20GB
Alfa Wassermann Ace Alera Operating System: MS-DOS 6.22
Alfa Wassermann Ace Alera Keyboard Type: 83 key
LCD Monitor
Type: 12.1 in. TFT Active matrix panel
Resolution: SVGA 800 pixels by 600 pixels
Printer
Type: Okidata B4200 Laser
Speed: 19 pages per minute maximum
Resolution: 600 by 1,200 dots per inch
Interface: Centronics parallel compatible
Paper Type: Standard letter
Capacity: 250 sheets
Alfa Wassermann Ace Alera Test Menu:
Routine Chemistry Assays:
Albumin
Bilirubin, Direct
Bilirubin, Total
Calcium, Arsenazo
Creatinine
Glucose
Inorganic
Phosphorus
Magnesium
Total Protein
Urea Nitrogen (BUN)
Uric Acid
Thyroid Assays:
Thyroxine,
Total (T4)
T – Uptake
Enzyme Assays:
Alkaline Phosphatase (ALP)
Alanine Aminotransferase (ALT)
Amylase (AMY)
Aspartate Aminotransferase (AST)
Creatine Kinase (CK)
Gamma-Glutamyl Transferase (GGT)
Lactate Dehydrogenase (LDH)
Lipase (LIP)
Cardiovascular Risk Assessment:
Apolipoprotein A1 (ApoA1)
Apolipoprotein B (Apo B)
Cholesterol
HDL Cholesterol,
Homogeneous
LDL Cholesterol,
Homogeneous
Lipoprotein (a)
Triglycerides
Anemia Assays:
Iron
Ferritin
TIBC, Direct
Transferrin
Electrolyte Assays:
Bicarbonate (CO2)
Chloride
Potassium
Sodium
Diabetic Monitoring:
Assay
Hemoglobin A1c
Microalbumin
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.