The Alfa Wassermann Ace will be refurbished by a factory trained service engineer.
Alfa Wassermann ACE
The Alfa Wasserman ACE system answers the very important needs of today's physician's office laboratory.
Alfa Wassermann ACE delivers:
Low cost-per-test
Minimal maintenance
Maximum up time
Superior throughput
Broad testing capabilities
Alfa Wassermann ACE software identifies and tracks samples and reagents by:
Lot number
Expiration date
Amount of remaining reagent
The Alfa means no more specimen and reagent confusion. Alfa Wassermann ACE automatically dilutes and repeats specimens based on preset criteria. It ensures fast, accurate reporting of abnormal test results by automatically diluting and repeating those tests without operator intervention.
Start-up time = 15 minutes from power-up.
Analysis Types = Spectrometric, Potentiometric (optional).
Assay Types = Final Point, Delta (two point), Slope (factor or calibrated), Quadratic.
Throughput = Up to 165 results/hour.
STAT Turnaround Time = Between 1 and 15 minutes.n test(s) ordered.
Calibration Frequency
Optical = Monthly sample delay and optical calibration.
Photometric = Test dependent (refer to page insert).
Analytical Temperature = 37 Deg. C.+- .3 Deg. C.
Ambient Room Temperature = 59 Deg. F. to 89.6 Deg. F.
Humidity = 20 to 80% RH (non-condensing)
Maximum Cuvette Capacity = 248
Power Rating
Analyzer = 100-120 VAC, 47/63 HZ, 5 Amps Max.
Optimal = 200-240 VAC, 47/63 HZ, 2.5 Amps Max.
Ace Nominal = 350 Watts Max (Analyzer + Printer + Monitor).
Monitor = 90-240 VAC, 50/60 HZ, 0.5 amp, 30 W.
Printer = 120 VAC, 1 amp (also see back of printer!).
Sample Delivery
Presentation to System: Closed or open tube, Sample cups individually, Sample cups in groups of up to 15 on cup segment.
Segment Capacity = 5 in combination (cup and/or well).
Tube Size for Direct Sampling = 75 to 100 mm length; 13 to 16 mm diameter.
Sample Capacity = 75-150 samples, 15 sample cups/cup segment, 30 samples wells/well segment.
Typical Volumes Used = 3-20 uL.
Level Detection = Automatic with liquid level sensor.
Dimensions
Analyzer
Height = 43.2 cm (17.0 in.).
Width = 69.9 cm (27.5 in.).
Depth = 57.2 cm (22.5 in.).
Raised Height = 91.4 cm (36.0 in.).
Weight = 68.3 cm (150 lbs.).
Recommended Minimum Clearances
Analyzer - Maintain a clearance of 7.6 cm (3.0 inches) behind the analyzer for proper air flow throught the exhaust vent and for cable connections. A space of 15.2 cm (6.0 inches) should be left free at either side of the analyzer to allow for air circulation and to allow for easy access to replace the air filter and remove cuvette waste. A space of 91.4 cm (39.0 inches) to raise the deck.
Test Menu:
Routine Chemistry Assays:
• Albumin
• Bilirubin, Direct
• Bilirubin, Total
• Calcium, Arsenazo
• Creatinine
• Glucose
• Inorganic
• Phosphorus
• Magnesium
• Total Protein
• Urea Nitrogen (BUN)
• Uric Acid
Thyroid Assays:
• Thyroxine, Total (T4)
• T - Uptake
Enzyme Assays:
• Alkaline Phosphatase (ALP)
• Alanine Aminotransferase (ALT)
• Amylase (AMY)
• Aspartate Aminotransferase (AST)
• Creatine Kinase (CK)
• Gamma-Glutamyl Transferase (GGT)
• Lactate Dehydrogenase (LDH)
• Lipase (LIP)
Cardiovascular Risk Assessment:
• Apolipoprotein A1 (Apo A1)
• Apolipoprotein B (Apo B)
• Cholesterol
• HDL Cholesterol, Homogeneous
• LDL Cholesterol, Homogeneous
• Lipoprotein(a)
• Triglycerides
Anemia Assays:
• Iron
• Ferritin
• TIBC, Direct
• Transferrin
Electrolyte Assays:
• Bicarbonate (CO2)
• Chloride
• Potassium
• Sodium
Diabetic Monitoring Assay:
• Hemoglobin A1c
• Micro-albumin
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.