Over 1550 Total Lots Up For Auction at Four Locations - NJ 01/16, PA 01/17, WA 01/21, NY 01/22

spacer
SIEMENS Bayer Advia 1800 Chemistry Analyzer
SIEMENS Bayer Advia 1800 Chemistry Analyzer

For Sale SIEMENS Bayer Advia 1800 Chemistry Analyzer

  • Condition : Used - Excellent
  • Weight : 1323.00 Lbs
  • In Stock : Yes
  • Date : January 09, 2025
  • Listing # : 1693587
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #1693587

  • Condition: Used - Excellent
  • Brand: SIEMENS
  • Type: Chemistry Analyzer
  • Model: Bayer Advia 1800
  • MPN: Bayer Advia 1800
  • Frequency (Hz): 50/60 Hz
  • Height: 44.6in 148.0cm
  • Length: 34.5in 87.6cm
  • Width: 58.3in 148.0cm
  • Ambient Humidity: 40%-70%
  • Auto-dilution: Automatic dilution from retained prediluted sample
  • Auto-repeat: Automatic repeat testing from the retained prediluted sample or original sample
  • Automatic Sample Predilution: Samples diluted 1:5 (30 μL sample + 120 μL saline generates up to 15 tests)
  • Average Consumption: 30 liters per hour
  • Average Reagent Volume: 80-120 μL per test
  • Average Thermal Output: 4229 BTU/Hr
  • Channels: 200 channels
  • Data Storage: 70,000 patient tests
  • Electrode Life: 30,000 samples or 3 months
  • Interface: RS232
  • Onboard Stability: Up to 60 days
  • Operating Temperature: 18°-30°C/64°-86°F
  • Original Sample Volume: 2 to 30 μL
  • Predilution Tray: 120 dilution cuvettes
  • Reaction Times: 3, 4, 5, 10, 15, and 21 minutes
  • Reagent Capacity Onboard: 52 colorimetric methods
  • Reagent Tray: 2 trays, 56 positions each, refrigerated
  • Tests Per Hour: Up to 1800 tests/hour: 1200 tests/hour colorimetric, 600 tests/hour ISE
  • Throughput Rate: 600 tests/hour; 200 tubes/hour
  • Wavelengths: 340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, and 884 nm
The Siemens Bayer Advia 1800 may be purchased in 1 of 2 ways listed below.

1.) Siemens Bayer Advia 1800 complete, working when shut down, cleaned, and crated.

2.) Siemens Bayer Advia 1800 refurbished by a factory trained service engineer, with completed manufacture specific preventive maintenance documentation, and crated.

***Don't forget to ask for your multiple unit, reagent, and consumable discount. ***


The Siemens Bayer Advia 1800

The ADVIA 1800 Clinical Chemistry System pushes the limit of productivity of the core lab and meets the turnaround-time (TAT) goals of today’s laboratories. Its extensive and growing menu allows integration of general clinical chemistry testing with testing for drugs-of-abuse, therapeutic drug monitoring (TDM), special chemistry and specific proteins like Cystatin C and CardioPhase hsCRP.
The ADVIA 1800 Clinical Chemistry System is an ideal solution for mid- to high-volume chemistry analysis. Featuring intuitive new software and capabilities, it’s designed to deliver power and speed to meet the most demanding performance needs. The ADVIA 1800 System moves laboratories to smarter chemistry testing.
The Siemens Bayer Advia 1800 System Features
Automation ready design
• Point-in-space aspiration offers connectivity to a track, VersaCell or rack handler without robotics or special hardware
• Redundant sample loading for built-in backup and easy handling of non-routine samples
• Direct sampling from track prevents detaining tubes at analyzer and reduces aliquoting

Peak productivity
• Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks
• 200 Basic metabolic panels per hour to meet turnaround-time demands
• Automatic Sample Retain technology provides the ability to perform reruns and dilutions without the need to retrieve primary tubes
• Consolidation power with a comprehensive menu, consistent cycle times, speed and open application capability

Total system reliability
• Minimal-maintenance ISEs
• Robust hardware and simplified software design, with automatic calibration validation and tracking
• Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion
• Direct water connection
• Remote diagnostics and ILQC (Inter-Laboratory Quality Control) options

Easy efficiency
• Large onboard reagent capacity and optional concentrated reagents reduce interruptions
• High-resolution touchscreen delivers push-button operation
• Reagent pause capability and onboard Sample Pause button make loading easy
• Minimal maintenance requirements, including no-maintenance oil bath
• Sample integrity checking, including serum indices reporting, short sample flagging and clot detection, reduces manual intervention
Siemens Bayer Advia 1800 Technical Specification Overview

• Type of System: Random, continuous access, batch, discrete processing
• Throughput Rate: Up to 1800 tests/hour: 1200 tests/hour colorimetric, 600 tests/hour ISE
• Assay Capacity Onboard: 55 including 3 ISE

Siemens Bayer Advia 1800 Sample Handling

• Sample Tubes: 5 mL, 7 mL, 10 mL tubes, 2 mL sample cups
• Sample Tray: 84 samples, positive sample identification
• Sample Rack Handler: (optional) Universal 5-position rack, 425 total onboard capacity, continuous feed capability
• Sample Integrity Check Qualitative: check for hemolysis, lipemia, and icterus
• STAT Sample Loading: 84, not dedicated
• Bar Codes: Interleaved 2 of 5, Code 39, Code 128, Codabar (NW7)
• Auto-repeat: Automatic repeat testing from the retained prediluted sample or original sample
• Auto-dilution: Automatic dilution from retained prediluted sample
• Auto-reflex Testing: Automatic ability to perform 3 additional tests based on results of first test
• Primary Probe: Liquid Level Sensing, Crash Protection, Clot/Clog Detection, Short Sample Detection

Siemens Bayer Advia 1800 Microvolume Technology

• Automatic Sample Predilution: Samples diluted 1:5 (30 μL sample + 120 μL saline generates up to 15 tests), retained for auto-repeat until results are available
• Predilution Tray: 120 dilution cuvettes
• Original Sample Volume: 2 to 30 μL; average of 2-3 μL per test
• Average Reagent Volume: 80-120 μL per test
• Storage Capacity Onboard: 25,200 tests average; Usage of concentrated reagents increases maximum capacity

Siemens Bayer Advia 1800 Reaction Area

• Reaction Tray: 221 reusable plastic cuvettes
• Cuvette Optical Path Length: 10 mm
• Reaction Bath: Inert fluorocarbon oil circulation system, 37°C
• Photometer: 14 fixed wavelengths (340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, and 884 nm)
• Light Source: 12 V, 50 W halogen lamp, cooled by forced water circulation
• Assay Methods: Endpoint, rate reaction, 2-point rate, multipoint homogeneous immunoassay
• Reaction Times: 3, 4, 5, 10, 15, and 21 minutes
• Automatic Correction: Serum blank, cell blank, measurement point change, sample volume change in reassay
• Point Forwarding: Automatically extends linearity over assay range samples

Siemens Bayer Advia 1800 Reagent Handling

• Reagent Tray: 2 trays, 56 positions each, refrigerated
• Reagent Capacity Onboard: 52 colorimetric methods
• Dispensing System: 2 probes with Liquid Level Sensing and Liquid Surface Verification
• Reagent Wedges: 20, 40, 70 mL bar-code-labeled wedges
• Reagent Inventory Management: Tracks tests remaining, lot number, onboard stability, and expiration date
• Reagent Dilutions: Capability to dilute concentrated reagents onboard
• Onboard Stability: Up to 60 days

Siemens Bayer Advia 1800 Open System Capability

• Channels: 200 channels, includes user-defined applications
• 3rd Party Applications: Varies by country, can be configured on system

Siemens Bayer Advia 1800 ISE

• ISE: Indirect simultaneous measurement of Na+, K+, Cl -
• Sample Volume: 22 μL for all three tests
• Priming: Automatic priming cycle
• Electrode Shelf Life: 30,000 samples or 3 months
• Throughput Rate: 600 tests/hour; 200 tubes/hour


Siemens Bayer Advia 1800 Calibration/QC

• Calibration Interval: Up to 60 days, tracked by software
• Auto-calibration/Auto-QC: User-defined time interval or with new reagent container
• View Calibration/QC Data: Graphical display of calibration curves and QC; Siemens Remote Service QC monitoring
• Calibration/Control :Tray 61 refrigerated positions for calibrators, controls, and diluents

Siemens Bayer Advia 1800 Data Management

• Operating Computer: Windows XP, 1 GB RAM, touch screen monitor 19”
• System Documentation: Operator manual and assay sheets online
• Host Interface: RS 232C bidirectional
• Data Storage: 70,000 patient tests
• Onboard Maintenance Logs: Schedule and monitor routine maintenance activities via software
• Host Query: ASCII; system requests work order or batch of work orders from host

Siemens Bayer Advia 1800 General Specifications

• Power Requirements: 200/220/230/240 V +/– 10%, 20 A, 50/60 Hz, 3 KVA
• Water Requirements: Deionized water from pressurized water (10-30 psi/169-207 KPa) Average Consumption: 30 liters per hour
• Drain Requirements: Minimum of 40 liters per hour
• Dimensions: ADVIA 1800: 44.6 (h) x 58.3 (w) x 34.5 (d) in, 113.3 (h) x 148.0 (w) x 87.6 (d) cm
• Universal Rack Handler: 37 (h) x 29 (w) x 41 (d) in, 86.4 (h) x 73.7 (w) x 104.1 (d) cm
• Weight: ADVIA 1800: 1,323 lbs (600 kg)
Universal Rack Handler: 178 lbs (81 kg)
• Compliance: UL, cUL, CE
• Noise Specifications: Open cover less than 70 db
• Average Heat Output: 4,299 BTU/hour @ 50 Hz, 3,023 BTU/hour @ 60 Hz
• Operating Temperature Range: 18°-30°C/64°-86°F
• Ambient Humidity: 40%-70%

Siemens Bayer Advia 1800 Test Menu

General Chemistry
• Acid Phosphatase (Total & NP)
• Alanine Aminotransferase
• Alanine Aminotransferase (P5P)
• Albumin (BCG)
• Alkaline Phosphatase (AMP)
• Ammonia
• Amylase
• Aspartate Aminotransferase
• Aspartate Aminotransferase (P5P)
• Bilirubin, Direct
• Bilirubin, Total
• Calcium (Arsenazo)
• Calcium (CPC)
• Carbon Dioxide
• Chloride (ISE)
• Cholesterol
• Cholinesterase
• Creatine Kinase
• Creatinine (Jaffé)
• Creatinine (Enzymatic)
• Gamma-Glutamyltransferase (GGT)
• Glucose Hexokinase
• Glucose Oxidase
• Hemoglobin A1c
• HDL Cholesterol, Direct
• Iron
• Lactate
• Lactate Dehydrogenase (L-P)
• Lactate Dehydrogenase (P-L)
• LDL Cholesterol, Direct
• Lipase
• Magnesium
• Pancreatic Amylase
• Phosphorus, Inorganic
• Potassium (ISE)
• Sodium (ISE)
• Total Iron Binding Capacity (TIBC)
• Total Protein
• Total Protein (Urine/CSF)
• Triglycerides
• Urea Nitrogen
• Uric Acid

Specific Proteins
• α1- Acid Glycoprotein
• Antistreptolysin O
• α-1 Antitrypsin
• Apolipoprotein A1
• Apolipoprotein B
• β2 Microglobulin
• Complement 3 (C3)
• Complement 4 (C4)
• C-Reactive Protein (CRP)
• CRP, Wide Range (wr-CRP)
• CardioPhase hsCRP
• Cystatin-C
• Ferritin
• Haptoglobin
• Immunoglobulin A (IgA)
• Immunoglobulin G (IgG)
• Immunoglobulin M (IgM)
• Lipoprotein(a)
• Microalbumin
• Myoglobin
• Prealbumin
• Rheumatoid Factor (RF)
• Transferrin

Drugs of Abuse/Toxicology
• Acetaminophen
• Amphetamines
• Barbiturates (Serum)
• Barbiturates (Urine)
• Benzodiazepines (Serum)
• Benzodiazepines (Urine)
• Cannabinoids (THC)
• Cocaine Metabolite
• Ecstasy
• Ethyl Alcohol
• Methadone
• Methadone Metabolites, EDPP
• Opiates
• Phencyclidine
• Propoxyphene
• Salicylate
• Tricyclic Antidepressants

Validity Testing
• Creatinine Specimen Validity Test
• Nitrite Specimen Validity Test
• Oxidant Specimen Validity Test
• pH Specimen Validity Test
• Specific Gravity Specimen Validity Test

Therapeutic Drug Monitoring (TDM)
• Carbamazepine
• Digoxin
• Gentamicin
• Lithium
• Phenobarbital
• Phenytoin
• Theophylline
• Tobramycin
• Valproic Acid
• Vancomycin

Operating Computer : Windows XP, 1 GB RAM, touch screen monitor 19”
Sample Tubes: : 5 mL, 7 mL, 10 mL tubes, 2 mL sample cups
Type Of System : Random, continuous access, batch, discrete processing
View Calibration/qc Data : Graphical display of calibration curves and QC; Siemens Remote Service QC monitoring
Auto-calibration/auto-qc : User-defined time interval or with new reagent container
Bar Codes : Interleaved 2 of 5, Code 39, Code 128, Codabar (NW7)
Calibration/control : Tray 61 refrigerated positions for calibrators, controls, and diluents
Drain Requirements : Minimum of 40 liters per hour
Ise : Indirect simultaneous measurement of Na+, K+, Cl -
Calibration Interval : Up to 60 days, tracked by software
Primary Probe : Liquid Level Sensing, Crash Protection, Clot/Clog Detection, Short Sample Detection
Priming : Automatic priming cycle
Sample Integrity Check Qualitative : check for hemolysis, lipemia, and icterus
Sample Tray : 84 samples
Sample Volume : 22 μL for all three tests
System Documentation : Operator manual and assay sheets online

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
JM Scientific
profile image
Shop with confidence
Citi Capital Groupspacer
Moveitem Shippingspacer
Send the Seller a message: