For Sale SIEMENS Definition Flash CT Scanner

  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : June 19, 2025
  • Listing # : 5324373
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #5324373

  • Condition: Used - Good
  • Brand: SIEMENS
  • Type: CT Scanner
  • Model: Definition Flash
  • MPN: Definition Flash
  • S/N: 73039
*Ad subject to priority sale
Model 10430603 S/N 73039
YOM 2009
Double 2020 CT Tube
Straton MX
Model 8402062 S/N 920451701
Straton MX P
Model 10414539 S/N 398192003
Straton MX
Model 8402062 S/N 940152004
Features and Benefits
Split-second scanning
The Dual Source technology of SOMATOM Definition Flash enables scanning at Flash speed so that diagnostic images can be acquired on different patients, regardless of their heart rate, breath holding ability or ability to remain still. This eliminates sedation for children, streamlines the procedure for trauma patients and solves the challenges of all complex cardiac cases. With SOMATOM Definition Flash, speed means more confident diagnosis.
Low-dose CT Definition
With Dual Source technology and Stellar Detectors, SOMATOM Definition Flash sets the standard for dose efficiency. CARE Dose4D, CARE kV and SAFIRE1 (Sinogram Affirmed Iterative Reconstruction) form a comprehensive portfolio of high-quality dose reduction.
What is needed, however, is the right dose, i.e. the ideal dose to ensure high image quality.
In this sense, Siemens' efforts are guided by the principle of the lowest possible dose. Only Dual Source technology can make scans fast enough to achieve high image quality at standard dose levels and thus define the correct limit for low dose in scanning. This means: cardiac imaging in sub-mSv, routine triple-rule-outs below two mSv and low-dose pediatric scans with the help of CARE Child.
Dual Source Dual Energy for all patients
With Dual Source Dual Energy technology, each scan produces two sets of data. This not only saves an unenhanced scan, but also improves the quality of routine and specialist examinations with dose similar to conventional 120 kV scans. SOMATOM Definition Flash features the ability to obtain quality images at low kV, reduce dose, assess cardiac and coronary morphology, and visualize quantitative information on the perfusion of blood vessels and organs.
Quantitative Diagnostic Imaging with syngo.via
Regardless of the number of clinical exams or the pathology, syngo.via helps you prepare clinical cases, facilitates interdisciplinary collaboration, and facilitates reliable and fast diagnoses. In the case of cardiovascular CT, it allows you to rule out coronary artery disease in less than a minute. You can immediately start examining coronary vessels, valves, calcium, and functional parameters, to obtain a complete cardiac assessment in less than four minutes. And these are just some of the ways syngo.via can improve and accelerate your daily routine. Based on a client-server architecture, syngo.via supports efficient task sharing and collaboration, with capacity for up to ten users per session.
CLINICAL USE
Child body/chest CT. Without sedation.
Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 0.34 s
Scan length: 99 mm
Rotation time: 0.28 s
Heart rate independent temporal resolution: 75 ms
Tube settings: 120/120 kV, 5 mAs/rot
Effective dose: 2.3 mSv
Chest CT. Without breath hold.
Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 1.3 s
Scan length: 586 mm
Rotation time: 0.28 s
Heart rate independent temporal resolution: 75 ms
Tube settings: 100/100 kV, 362 mAs/rot
Effective dose: 3.7 mSv
Triple cutoff. Typically below 2 mSv.
Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 0.6 s
Scan length: 290 mm
Rotation time: 0.28 s
Heart rate independent temporal resolution: 75 ms
Tube settings: 100/100 kV, 370 mAs/rot
Effective dose: 1.9 mSv
Diagnostic image quality. For patients up to 307 kg.
Collimation: 32 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 31 s
Scan length: 480 mm
Rotation time: 0.5 s
FoV: 780 mm
Tube settings: 120/120 kV, 741 mAs
CTDlvol: 60.11 mGy
Patient weight: 181 kg
Trauma exams. 1640 mm in less than 5 seconds.
Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 3 s
Scan length: 986 mm
Rotation time: 0.28 s
Heart rate independent temporal resolution: 75 ms
Tube settings: 140 kV, 200 mAs/rot
Coronary and neurological CT angiography. Only one scan.
Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 2.07 s
Scan length: 571 mm
Rotation time: 0.28 s
Heart rate independent temporal resolution: 75 ms
Tube settings: 120/120 kV, 182 mAs/rot
Effective dose: 8 mSv
Dose insensitive dual energy. Always a second contrast.
Collimation: 64 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 12 s
Scan length: 287 mm
Rotation time: 0.33 s
Tube settings: 100/140 kV, 50/60 mAs
Effective dose: 2.6 mSv
Dose-insensitive Dual Energy. Save an extra scan.
Collimation: 32 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 28 s
Scan length: 642 mm
Rotation time: 0.5 s
Tube settings: 100/140 kV, 81/68 mAs
Effective dose: 6.2 mSv
Routine sub-mSv cardiac imaging. Even in patients up to 90 kg.
Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 0.28 s
Scan length: 128 mm
Rotation time: 0.28 s
Heart rate independent temporal resolution: 75 ms
Tube settings: 80/80 kV, 300 mAs/rot
Effective dose: 0.4 mSv
Patient weight: 88 kg
TAVI planning with CT With only 40 mL of contrast.
Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 1.5 s
Scan length: 724 mm
Rotation time: 0.28 s
Heart rate independent temporal resolution: 75 ms
Tube settings: 100/100 kV, 258 mAs/rot
Effective dose: 1.7 mSv
All heart rates. No exclusions.
Collimation: 128 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 4 s
Scan length: 96 mm
Rotation time: 0.28 s
Tube settings: 100 kV, 265 mAs/rot
Effective dose: 3.6 mSv
Heart rate: 48–107 bpm
Exercise myocardial perfusion. Blood flow and volume.
Collimation: 32 x 1.2 mm
Spatial resolution: 0.30 mm
Scan time: 28 s
Scan length: 72 mm
Rotation time: 0.3 s
Tube settings: 100 kV, 370 mAs/rot
Effective dose: 9.6 mSv
Cardiac Dual Energy. At a temporal resolution of 75 ms.
Collimation: 64 x 0.6 mm
Spatial resolution: 0.30 mm
Scan time: 10 s
Scan length: 132 mm
Rotation time: 0.28 s
Tube settings: 100/140 kV, 164/140 mAs/rot
Heart rate: 44-60 bpm