Listing: #5683681
Electrocardiograph ECG/EKG
Good Working Condition
TESTED FUNCTIONAL
Can be shipped with or without the trolley
FEATURES:
The GE MAC 1200 is a digital 12-lead EKG Machine that offers comprehensive ECG solutions. The MAC 1200 offers practical features that help meet the demanding needs of hospitals, clinics, office-based practices, and clinical trials. Its advanced algorithm capabilities, seamless connectivity to the CS and MUSE Cardiology Information Systems and easy-t0-use features; provide maximum quality and convenience. Resting ECGs acquired in the 12-lead mode, and the corresponding data, can then be transmitted to a PC, CardioSys system, or to a MUSE CV system. This EKG Machine is equipped with electronic utilities that ensure artifact-free recordings. Among these are the automatic baseline adjustment and the anti-drift system (Cubic Spline and ADS).
This system can be configured to meet the needs of hospitals, clinics, and office-based practices
Allows access to EKG data gathered throughout a provider network, assuring high quality and continuity of care
Comprehensive solution for EKG requirements
Waveform LCD display
Interpretive EKG
Full-size paper reports
Portable with a built-in battery
Measurements, interpretation, and memory available in any combination
Simultaneous 12-lead ECG acquisition and analysis
Compact, lightweight design with carrying handle
Field upgradability
Signal Processing:
Acquisition: 12 leads simultaneously.
Signal input: Type CF according to IEC.
Digital sampling rate: 1000 samples/second/channel.
Dynamic range: Differential signals for AC voltage , 10mV Superimposed DC voltage (Polarization voltage) 600mV.
Resolution: 5 uV.
Frequency response: 150 Hz.
Common mode rejection:> 140 dB.
Input impedance: > 100 M ohms.
Leakage current: < 10uA.
Pacemaker detection sensitivity: All leads, duration 0.1 2.5 ms, amplitude > 5 mV.
Special Functions:
Anti Drift System (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes.
Baseline adjustment: ECG presentation on the averaged baseline.
Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break. Every single electrode is monitored.
Copy: In the automatic 12 lead modes, after ECG, recording, copies of the ECG can be printed.
Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input.