The Siemens Advia 120 Hematology System may be purchased in 1 of the 2 ways listed below.
Option 1
• Complete with required operating accessories
• Working when shut down
• Cleaned
• No warranty “As Is”
• Crated/Packaged.
Option 2
Refurbished Siemens Advia 120
• Everything in and on the unit is thoroughly cleaned, tested, and painted if needed.
• Completed manufacture specific Preventive Maintenance documentation.
• All required operating accessories.
• Ready for use in the laboratory.
• 90 day parts and technical support warranty.
• Installation, Training, and Service agreements may be available for qualified customers.
• Crated/Packaged.
***Don't forget to ask for your multiple unit, reagent, and consumable discount. ***
Siemens Advia 120 Hematology System
The ADVIA® 120 System offers a unique portfolio of diagnostic assays and gold-standard flow cytometry testing. The system satisfies the demands of laboratories through comprehensive testing parameters, flexible sample handling, a user-defined interface, and a compact bench-top design.
• Automates hematology workflow without the need for large track-based systems or reflexive testing
• Maximizes efficiency through user-defined screen configurations and reports
• Simplifies maintenance with Unifluidics™ Technology through reduced fluidics, elimination of pinch valves, and automated daily cleaning
• Streamlines productivity with a 150 capacity rack-based auto sampler, allowing 75 minutes of true walk-away time
• Reduces the need for manual slide production and review by utilizing WBC and RBC/PLT technology and high specificity
• Maximizes the effectiveness of costly platelet transfusions with accurate results the first time—even at very low platelet levels
Siemens Advia 120 Hematology System Features and Benefits
The ADVIA® 120 Hematology System can automate your hematology lab without the need for large track-based systems or reflexive testing. This is how Siemens delivers practical solutions to your hematology lab.
The system streamlines workflow and maximizes productivity by eliminating the majority of commonly performed manual steps. It delivers the gold-standard in testing methodology for optimum results while offering the simplicity and flexibility you need for easy integration into your lab.
ADVIA technology utilizes peroxidase staining—the gold-standard in differential testing. This primary methodology of the ADVIA Hematology Systems also provides a secondary total white cell count that acts as an internal QC check to monitor sample integrity.
• Unique cytochemical differentiation of myeloid and lymphoid cells, and six-parameter differential supplies additional clinical information
• Direct measurements of intracellular hemoglobin provide sensitive and specific RBC morphology for the accurate and early indication of disease states
• Accurate platelet counts in the clinically significant range (excluding microcytic red cells and cell fragments) minimize the number of manual counts and unnecessary costly platelet transfusions
• Further isolate and identify disease states without additional labor or reagents through CSF and CHr testing capabilities
Maximize your workflow efficiency with gold-standard technology. With integrated and automated solutions from Siemens, you can scale from stand-alone instrumentation to complete automation as your productivity needs change.
Siemens Advia 120 Hematology System Technical Specifications
Performance Specifications:
WBC: 0.02 to 400 x 10 3/µL
RBC: 0.0 to 7.0 x 10 6/µL
PLT: 5.0 to 3500 x 10 3/µL
HB: 0.0 to 22.5 g/dL
Retic: 0.2 to 24.5%
Precision Parameters
• WBC: 7.5 Mean, 0.20 SD, & 2.7 CV
• RBC: 5.0 Mean, 0.06 SD, & 1.2 CV
• HB: 15.0 Mean, 0.14 SD, & 0.93 CV
• MCV: 90.0 Mean, 0.7 SD, & 0.78 CV
• PLT: 300.0 Mean, 8.8 SD, & 2.93 CV
• Retic%: 2.0 Mean, 0.25 SD, & 12.5 CV
Test Selectivity / Throughput
CBC: 120 samples/hour
CBC/DIFF: 120 samples/hour
CBC/DIFF/Retic: 74 samples/hour
CBC/Retic: 74 samples/hour
Retic: 74 samples/hour
Sample Modes / Volumes
Automatic Closed Tube: 175µL
Manual Closed Tube: 175µL
Manual Open Tube: 175µL
Weight and Dimensions
Analytical Module with Auto sampler:
Weight: 193 kg / 425 lbs
Height: 86 cm / 33.8 in
Width: 141 cm / 55.5 in
Depth: 68 cm / 26.8 in
Analytical Module without Auto sampler:
Weight: 163 kg / 360 lbs
Height: 86 cm / 33.8 in
Width: 81 cm / 31.9 in
Depth: 68 cm / 26.8 in
Workstation Specifications
Intel Pentium E6500 Dual Core 2.93 GHz
350W Desktop/Tower
3Gb/s 7200 RPM 16MB Cache Hard Drive
1 GB Memory Module
CD-RW
17” Color Monitor
Full-sized Keyboard (major languages)
Auto sampler Option:
150 Sample Capacity: 15 Racks with 10 tube capacity
Compatible tube types: Vacutainer®, Hemogard™, Monovette® (Sarstedt 2.6 mL tubes require rack modification), Greiner MicroSample Tubes, BD MAP tubes
Automatic discrimination of label codes: Codabar
Interleave 2 of 5 with and without check digit
Code 39
Code128 EAN and JAN (8 and 13)
Other Specifications:
Onboard analytical and wash reagents (1850 CBC/Diff tests)
Automated Daily Maintenance – fully programmable
Siemens Advia 120 Hematology System Test Menu
Parameters
CBC Results: WBC, RBC, HGB†, HCT, MCV, MCH, MCHC, CHCM, RDW, HDW, CH, CHDW, PLT
Differential Results (absolute and %): NEUT, LYMPH, MONO, EOS, BASO, LUC (Large Unstained Cells)
Platelet Results: PLT, MPV, PDW, PCT
Reticulocyte Results (absolute and %): RETIC, MCVr, CHCMr, RDWr**, HDWr**, CHr, CHDWr**
CSF assay results: Optional
Morphology results (User-definable)
WBC: Left Shift, Atypical Lymph, Blasts, Immature Granulocytes, Myeloperoxidase Deficiency
RBD and PLT: NRBC, ANISO, MICRO, MACRO, HC VAR, HYPO, HYPER, RBC Fragments, RBC Ghosts, Platelet Clumps, Large Platelets
Cbc/retic Throughput : 74 samples/hour
Cbc Throughput : 120 samples/hour
Manual Open Tube Volume : 175µL
Plt Precision Parameters : 300.0 Mean, 8.8 SD,
Retic% Precision Parameters : 2.0 Mean, 0.25 SD,
Retic Throughput : 74 samples/hour
Cbc/diff/retic Throughput : 74 samples/hour
Cbc/diff Throughput : 120 samples/hour
Hb Performance Specifications : 0.0 to 22.5 g/dL
Hb Precision Parameters : 15.0 Mean, 0.14 SD,
Mcv Precision Parameters : 90.0 Mean, 0.7 SD,
Plt Performance Specifications : 5.0 to 3500 x 10 3/µL
Cbc/diff/retic Throughput : 74 samples/hour
Rbc Performance Specifications : 0.0 to 7.0 x 10 6/µL
Cbc/diff Throughput : 120 samples/hour
Rbc Precision Parameters : 5.0 Mean, 0.06 SD,
Retic Performance Specifications : 0.2 to 24.5%
Hb Performance Specifications : 0.0 to 22.5 g/dL
Wbc Performance Specifications : 0.02 to 400 x 10 3/µL
Hb Precision Parameters : 15.0 Mean, 0.14 SD,
Wbc Precision Parameters : 7.5 Mean, 0.2 SD,
Mcv Precision Parameters : 90.0 Mean, 0.7 SD,
Plt Performance Specifications : 5.0 to 3500 x 10 3/µL
Automatic Closed Tube Volume : 175µL
Rbc Performance Specifications : 0.0 to 7.0 x 10 6/µL
Rbc Precision Parameters : 5.0 Mean, 0.06 SD,
Retic Performance Specifications : 0.2 to 24.5%
Manual Closed Tube Volume : 175µL
Wbc Performance Specifications : 0.02 to 400 x 10 3/µL
Wbc Precision Parameters : 7.5 Mean, 0.2 SD,
Automatic Closed Tube Volume : 175µL
Manual Closed Tube Volume : 175µL
Return Policy