ACIST CVi® helps protect patients with these quality control differentiators:
• Variable rate hand controller delivers precise contrast administration.
• Contrast tracking in real time helps monitor thresholds.
• Multiple back-up mechanisms detect air columns in the contrast tubing.
- These include: ACD, auto purge, auto refill, angled design and backlighting
Patient and cath lab team safety Reducing potential consequences
ACIST CVi® helps protect patients with these quality control differentiators:
• Variable rate hand controller delivers precise contrast administration.
• Contrast tracking in real time helps monitor thresholds.
• Multiple back-up mechanisms detect air columns in the contrast tubing.
- These include: ACD, auto purge, auto refill, angled design and backlighting
Product and Technical Specifications
CVi System
Flow Rates
Contrast: User-Responsive, pre-set Variable and Fixed rates from 0.8 to 40 ml/sec, in 0.1 ml/sec increments
Saline: Fixed rate: 1.6 ml/sec
Volume User-Responsive, pre-set limits with variable range of 0.8 to 99.9 ml, in 0.1 ml increments
Pressure Limits User Defined from 200 to 1200 psi
Fill Rate Manual or automatic refill of 3 ml/sec
Rise Time User-defined 0 to 1 sec, in 0.1 sec increments
Program Routine
Injection Modes
Cardiac: LCA, RCA, LV/Ao and User Defined
Peripheral Vascular: Pigtail, Selective, Microcatheter and User Defined
Monitoring Sensors Air Column Detect,* Isolation Manifold, Contrast Source Empty, Contrast Syringe Refill
and Contrast Source Isolation
Imaging Interface Synchronization** Able to synchronize with most brands of X-ray imaging equipment
Injection Delay** or X-ray Delay** 0–99.9 sec
KVO Feature*** Range of 0.1 to 10 ml/min with 20 min timeout: maximum of 200 ml of saline dispensed
Control Panel 27 cm (10.5 inches) Color Touch Screen
Flexible Mounting Configurations Table Mount with adjustable arm or stationary stem, Pedestal Cart
Pedestal Cart Dimensions Wheelbase footprint 53.3 X 63.5 cm (21 X 25 inches), height 91.4cm (36 inches)
Contrast Syringe 100 ml
Consumable Kit Configurations
Contrast Syringe (6 patient): Contrast Syringe with contrast tubing spike and clamp (for use in up to 6 patient cases)
AngioTouch Hand Controller
and Tubing: AngioTouch hand controller, injection line tubing and 3-way stopcock
Automated Isolation Manifold: Integrated system with automated isolation-manifold, low-pressure tubing and saline spike,
and supplied pressure transducer cartridge
Component Weights Power supply 5.5 kg (12 lb), control panel and stem 3.2 kg (7 lb), pedestal cart 10 kg (22 lb),
injector head 20.4 kg (45 lb), adjustable arm 0.66 kg (1.45 lb)
Power Requirements Factory selectable: 100 to 120 VAC, 50–60 Hz, 10 A maximum or 200 to 240 VAC,
50–60 Hz, 5 A maximum
Return Policy