WYATT TECHNOLOGY Viscostar II WV2-06 WYATT TECHNOLOGY VISCOSTAR II ONLINE DIFFERENTIAL VISCOMETER WYATT TECHNOLOGY Viscostar II WV2-06 WYATT TECHNOLOGY VISCOSTAR II ONLINE DIFFERENTIAL VISCOMETER WYATT TECHNOLOGY Viscostar II WV2-06 WYATT TECHNOLOGY VISCOSTAR II ONLINE DIFFERENTIAL VISCOMETER
WYATT TECHNOLOGY Viscostar II WV2-06 WYATT TECHNOLOGY VISCOSTAR II ONLINE DIFFERENTIAL VISCOMETER WYATT TECHNOLOGY Viscostar II WV2-06 WYATT TECHNOLOGY VISCOSTAR II ONLINE DIFFERENTIAL VISCOMETER WYATT TECHNOLOGY Viscostar II WV2-06 WYATT TECHNOLOGY VISCOSTAR II ONLINE DIFFERENTIAL VISCOMETER

For Sale WYATT TECHNOLOGY Viscostar II WV2-06 WYATT TECHNOLOGY VISCOSTAR II ONLINE DIFFERENTIAL VISCOMETER

  • Asking Price :$6,800.00 USD [convert]
  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : April 21, 2025
  • Listing # : 4385476
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4385476

  • Condition: Used - Good
  • Brand: WYATT TECHNOLOGY
  • Type: Lab - General
  • Model: Viscostar II WV2-06
  • MPN: WV2-06
  • Warranty: 30 day returns, purchaser responsible for shipping fees
WYATT TECHNOLOGY VISCOSTAR II ONLINE DIFFERENTIAL VISCOMETER

PN: WV2-06

MFG: 3/15

Condition: Used, in working condition

Specs(from Wyatt):

Maximum flow rate: 1-3mL/min (solvent dependent) Can be set with 3 different delay volumes (27 mL, 12 mL, 4 mL)

Measurement precision: 18 bits

Linearity: 0.5% of full scale

Integration time: Programmable from 0.1 sec to infinity in increments of 0.1 sec Maximum inlet pressure: 220kPa (31.9 psi)

Maximum system pressure: 690kPa (100 psi)

Maximum differential pressure: 5kPa (0.725 psi)

Maximum differential pressure noise: < 0.15 Pa (2.2E-5 psi)

Maximum differential pressure drift: < 2.5 Pa/hr (3.6E-4 psi/hr)

Capillary dimensions: 0.25mm ID x 660mm

Sample shear rate: 5000 Hz*

Cell volume: 33 μL / bridge arm

Sample temperature control range: 4ºC–60ºC, temperature regulated

Temperature stability: < 0.01C

2 analog output signals: Inlet pressure and differential pressure

Digital communications: Ethernet

Universal power input: 90-250VAC 50-60Hz

Display/User interface: 162.5mm 16-bit color high resolution

LCD display Auto-inject contact closure input

Allows multiple instruments to share a single with retransmit: synchronization signal

Transducer Protection System (TPS): Protects from over-pressure

External recirculation valve option: Allows software control solvent recirculation

Safety sensors: Vapor alarm for organic solvents and leak alarm for aqueous solvents

External alarm input: Allows a remote instrument to signal an alarm

Ambient temperature range: 0-40ºC

Dimensions: 168 mm x 357 mm x 595 mm (H x W x D)