We Have A Agilent 1100 VWD DAD HPLC System For Sale
The Agilent 1100 HPLC System guarantees the most efficient mixing and pulse-free solvent delivery for consistently fast and accurate results. The system’s optimized design using a quaternary pump allows variable stroke volumes for stable solvent flow. This electronically activated inlet valve runs synchronous to the pistons to eliminate vapor formation in volatile solvent, making the Agilent 1100 both remarkably easy-to-use and maintenance-free. It also features a high-speed proportioning valve and a pre-configured degasser, which allow convenient low-pressure mixing and a large solvent choice flexibility. The HPLC System’s vacuum degasser ensures reduced operating costs without the use of helium and optimum instrument performance.
The unit can be operated with a hand-held controller or computer running Clarity software. The HPLC System features extensive diagnostics with compatible data analysis software for on-site and remote trouble-shooting.
Tests performed on Agilent 1100 HPLC System
- Filter Test
- Dark Current Test
- Holmium Oxide Test
- Lamp Intensity Test
- Wavelength Intensity Test
- Baseline Noise Test
- G1311A Quaternary Pump Diagnostic Tests
- Pressure Test
- Leak Test
- G1316A Column Compartment Diagnostic Test
- Thermostat Test
- G1313A Autosampler Diagnostic Tests
- injector Steps
- 4 Peak Test (Isocratic Standard)
Agilent 1100 HPLC System with DAD Detector Specifications
Detection type: 1024-element photodiode array
Light Source: Deuterium and tungsten lamps
Wavelength Range: 190 - 950 nm
Short term noise (ASTM) Single
and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
Drift: 2 × 10-3AU/hr at 254 nm
Linear Absorbance range : > 2 AU (upper limit)
Wavelength accuracy: ± 1 nm
Slit width: 1, 2, 4 , 8, 16 nm
Diode Width: < 1 nm
Flow Cells:
Standard: 13 µl volume, 10 mm cell
path length and 120 bar (1760 psi)
pressure maximum
Semi-Micro: 5 µl volume, 6 mm cell
path length and 120 bar (1760 psi)
pressure maximum
High pressure: 1.7 µl volume, 6 mm cell
path length and 400 bar (5880 psi)
pressure maximum
500 nano: 0.5 µl volume, 10 mm cell
path length and 50 bar (725 psi)
pressure maximum
Control and Data Evaluation: Agilent ChemStation for LC
Analog Outputs:
Recorder/integrator: 100 mV or 1 V,
output range: 0.001 – 2 AU, two
outputs
Communications:
Controller-area network (CAN), GPIB,
RS-232C, APG Remote: ready, start,
stop and shut-down signals, LAN
Optional
Safety and Maintenance:
Extensive diagnostics, error detection
and display (through control module
and ChemStation), leak detection, safe
leak handling, leak output signal for
shutdown of pumping system. Low
voltages in major maintenance areas.
GLP Features:
Early maintenance feedback (EMF) for
continuous tracking of instrument
usage in terms of lamp burn time with
user-settable limits and feedback
messages. Electronic records of
maintenance and errors. Verification of
wavelength accuracy with built-in
holmium oxide filter.
Weight:
11 kg
25 lbs
Dimensions:
(height × width × depth)
140 × 345 × 435 mm
5.5 × 13.5 × 17 inches
Line voltage:
100–120 or 220–240 VAC, ± 10% Wide-ranging capability
Line frequency:
50 or 60 Hz, ± 5 %
Power consumption:
220 VA / 85 W / 290 BTU Maximum