Agilent 6460C Triple Quad LC/MS-MS System with Agilent 1260/1290 Infinity HPLC Front End
Overview:
The Agilent 6460C Triple Quad LC/MS with 1260/1290 Infinity HPLC is a high-performance analytical system designed for pharmaceutical, clinical, environmental, and food safety applications. Combining the sensitivity and precision of a triple quadrupole mass spectrometer with the reliability of the Agilent 1260/1290 Infinity HPLC platform, it delivers accurate and reproducible results for routine and complex analyses.
Includes:
-Agilent 6460C triple quadrupole mass spectrometer with Jet Stream ESI source
-Agilent 1260/1290 Infinity II UHPLC system (pumps, autosampler, column oven)
-Peak Scientific Genius nitrogen generator
-Vacuum pump (6460C)
-Configured workstation PC with Agilent MassHunter installed
-All Fluidic tubing, fittings, and LC-to-MS transfer lines
-All electrical, triggers, and communication cables
-N2 gas lines from generator to MS ion source
-Waste collection and vent lines
Features:
-Sub-femtogram sensitivity for plasma and urine quantitation.
-Rapid polarity switching for multi-analyte drug discovery and development studies.
-Multi-residue screening of pesticides, veterinary drugs, and mycotoxins in food samples.
-Trace-level detection of pharmaceuticals, pesticides, and emerging contaminants in environmental samples.
-Multi-drug confirmation, therapeutic drug monitoring, and forensic toxicology testing.
-Pharmaceutical quality control, impurity profiling, release testing, and stability studies.
-Targeted metabolomics, lipidomics, and biomarker quantitation for research applications.
-Integrated Peak Scientific Genius nitrogen generator providing continuous on-demand nitrogen supply.
-Eliminates the need for gas cylinders, reducing storage requirements and operational costs.
-Consistent gas purity for reliable performance in high-throughput and 24/7 laboratory operations.
Specifications:
Component Specification Details
Mass Spectrometer Model Agilent 6460C Triple Quadrupole (QqQ)
Ion Source Agilent Jet Stream (AJS) ESI
Mass Range 10–1,400 Da (Q1 & Q3)
MRM Speed Up to 500 transitions/sec
Polarity Switching ≤ 5 ms
Sensitivity Sub-femtogram (ESI-MRM, reserpine)
Resolution 0.7 Da FWHM (Q1 & Q3)
Ionization Modes ESI, APCI
UHPLC System Model Agilent 1290 Infinity II
Max Pressure 1,300 bar (130 MPa)
Flow Range 0.001–5.000 mL/min
Gradient Delay Volume < 25 µL
Carryover < 0.001%
Column Oven Range 10°C below ambient to 100°C
Detector 1290 Infinity II DAD
HPLC System Model Agilent 1260 Infinity II
Max Pressure 600 bar (60 MPa)
Flow Range 0.001–10.000 mL/min
Application Routine analysis, method development, prep-scale
Integration Native MassHunter LC/MS control
Nitrogen & Vacuum N₂ Generator Peak Scientific Genius Series
N₂ Purity ≥ 99.5%
N₂ Flow Matched to 6460C requirements
Roughing Pump Included, matched to fore-vacuum specifications
Connections All gas, fluidic, electrical, and communication lines included
Data System Software Agilent MassHunter Workstation
Modules Acquisition (B.09+) & Quantitative Analysis
Acquisition Modes MRM, Dynamic MRM, MS Scan, Product Ion, Neutral Loss, Precursor Ion, SIM
Compliance 21 CFR Part 11, GLP/GMP Audit Trail
Workstation Configured Windows 10/11 PC
Application areas:
• Pharmaceutical
• Bioanalysis
• Food safety
• Environmental
• Clinical toxicology
• Forensic
• CRO/contract lav
• Academic research
• Metabolomics
• GLP / GMP regulated
International Diagnostic Equipment
- Call or email with your questions, Hablamos Español
- Ship from: IDE - Southern California. Global Shipping
- Details of item must be read carefully before buying and /or requesting return
Disclaimer:
"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.