Over 150 Missouri Auctions End Tomorrow 06/05 - Bid Now

spacer
MINDRAY AG Mindray AG+O₂ Anesthesia Gas Module Technical Data Module MINDRAY AG Mindray AG+O₂ Anesthesia Gas Module Technical Data Module MINDRAY AG Mindray AG+O₂ Anesthesia Gas Module Technical Data Module
MINDRAY AG Mindray AG+O₂ Anesthesia Gas Module Technical Data Module MINDRAY AG Mindray AG+O₂ Anesthesia Gas Module Technical Data Module MINDRAY AG Mindray AG+O₂ Anesthesia Gas Module Technical Data Module

For Sale MINDRAY AG Mindray AG+O₂ Anesthesia Gas Module Technical Data Module Parts P/N AG

  • Part Number : AG
  • Qty. Available : 5
  • In Stock : Yes
  • Date : May 29, 2026
  • Listing # : 5681038
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #5681038

  • Part #: AG
  • Description: Mindray AG+O₂ Anesthesia Gas Module Technical Data
  • Brand: MINDRAY
  • Type: Module
  • Warranty: 180 DAYS
Mindray AG+O₂ Anesthesia Gas Module Technical Data
1. General Description
The Mindray AG+O₂ module is a mainstream sidestream anesthesia gas monitoring module integrated with oxygen measurement function. It continuously monitors respiratory and anesthetic gas parameters including O₂, CO₂, N₂O and five common anesthetic agents, calculates real-time MAC value, and supports full inspired/expired gas detection. Widely compatible with Mindray uMEC, BeneView, Passport series patient monitors.
2. Measured Parameters
2.1 Oxygen (O₂)
- Measurement Principle: Fuel cell / Paramagnetic oxygen sensing
- Measurement Range: 0% ~ 100% O₂
- Accuracy: ±1% (0%~60%); ±2% (60%~100%)
- Resolution: 0.1%
- Parameters Displayed: FiO₂ (Inspired O₂), EtO₂ (End-tidal O₂)
2.2 Carbon Dioxide (CO₂)
- Measurement Principle: NDIR (Non-Dispersive Infrared)
- Measurement Range: 0 ~ 150 mmHg
- Accuracy: ±2 mmHg (0~40 mmHg); ±5% FS (40~150 mmHg)
- Display Parameters: FiCO₂, EtCO₂, RR (Respiratory Rate), CO₂ waveform
2.3 Nitrous Oxide (N₂O)
- Measurement Range: 0% ~ 100%
- Accuracy: ±2% (0~70%); ±3% (70%~100%)
- Display Parameters: FiN₂O, EtN₂O
2.4 Anesthetic Agents (5 Agents Auto-Identification)
Supports Halothane, Isoflurane, Enflurane, Sevoflurane, Desflurane
- Concentration Range: 0 ~ 10% (vol)
- Accuracy: ±0.2% or ±10% reading (whichever greater)
- Function: Real-time MAC (Minimum Alveolar Concentration) calculation and display
3. Sampling System Specifications
- Sampling Mode: Sidestream gas sampling
- Adjustable Sampling Flow Rate: 70 ~ 200 ml/min
- Standard Sampling Delay: ≤ 2.5 s (3m sampling line)
- Warm-up Time: Meet ISO standard within 45 seconds; full precision stabilization within 10 minutes
- Gas Filter: Built-in water & dust filter, anti-blocking design
4. Physical & Electrical Parameters
- Dimension: 80 × 107 × 51.5 mm
- Power Consumption: ≤ 3.7 W (low power design)
- Working Temperature: 0 ℃ ~ +40 ℃
- Storage Temperature: -20 ℃ ~ +60 ℃
- Humidity: 10% ~ 90% RH (non-condensing)
5. Compatibility
Compatible with Mindray uMEC series, BeneView N/M series, Passport series patient monitors, supporting plug-and-play hot swap.
6. Certification & Standard
Compliant with IEC 60601-1, IEC 60601-2-55 medical safety and performance standards, ISO clinical monitoring specifications.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Star 9 Biological Technology Co., Ltd.
profile image