Over 1650 Total Lots Up For Auction at Five Locations - NJ Cleansweep 05/07, NJ Cleansweep 05/08, CA 05/09, CO 05/12, PA 05/15

spacer
PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module
PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module PHILIPS Vuelink Module

For Sale PHILIPS Vuelink Module

  • Asking Price :$125.00 USD [convert]
  • Condition : Used - Good
  • Est. Shipping : Calculate
  • Weight : 1.00 Lbs
  • Qty. Available : 4
  • In Stock : Yes
  • Date : April 29, 2025
  • Listing # : 5097879
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #5097879

  • Condition: Used - Good
  • Brand: PHILIPS
  • Type: Module
  • Model: Vuelink
  • MPN: 1049152
  • Height: 7 inches
  • Length: 5 inches
  • Width: 7 inches
The Philips M1032A Vuelink Module is a communication module that allows other monitors or devices to interface with a Philips MP or MX series monitor. This allows parameters and readings to directly be shown on a Philips monitor. There are 5 different hardware options for these modules. You must get the correct options for your category. These categories are Auxiliary(A01), Vent(A02), Gas Analyzer(A03), Anesthesia(A04), Auxiliary(A05). This module needs to be be loaded with the specific driver for communication to work. It uses a specific cable for each external device it communicates with.

We are an R2v3/RIOS recommended certified electronics recycler. Every item we sell is evaluated by our technicians according to the R2v3 guidelines and is classified as the following:

Items Included: 1x PHILIPS M1032A VUELINK MODULE

Missing Components: manual, accessories

Cosmetic Description:
C5: Used very good
⦁ cosmetic blemishes include minor scratches and/or other surface imperfections from consistent use, but equipment is in good condition.
⦁ minor wear of labeling may be visible
⦁ minor dents and areas of discoloration from the removal of tags
⦁ no missing parts

Scuffs/Scratches/Marks: scratches and scuffing on unit from past use

R2v3 Functionality:
F3: Key Function working (appendix C - Test and repair)
⦁ a subset of the primary functions of the device that an ordinary user of the device expects to function are verified working through manual or software testes
⦁ software may not be loaded or configured
⦁ hardware required for key functions to be tested may have been removed after testing( E.G. Hard drive)
⦁ may be missing components or parts not essential to key functions
⦁ secondary functions may be not be tested or working
⦁ may not include focus materials (e.g. Battery ) that are not working or not tested
⦁ all missing components or parts will be listed for each item

"""NOTE:- LEGAL DISCLAIMER PURCHASE TERMS Buyer accepts all responsibility for the electrical safety inspection, testing and calibration when applicable, of a purchased item. Medical and dental items must be inspected for safety by a biomedical technician before being placed into use. The buyer is responsible for ensuring the safety of the item for its intended use. If the item is to be used in conjunction with patient care and/or diagnosis, it is the responsibility of the buyer to get proper certifications or licenses for the use of the item."""

Return Policy

30-day D.O.A. applies if an item arrives in any condition other than what is listed in the description.
Seller Information
Sunnking inc.
(2)
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: