Listing: #4697118
Specifics
The ACIST RXi System is indicated for obtaining intravascular pressure measurements for use in the diagnosis and treatment of coronary and peripheral artery disease. The ACIST Navvus MicroCatheter is intended for use with the ACIST RXi System.
The ACIST RXi System is designed to provide hemodynamic information for the diagnosis and treatment of coronary and peripheral artery disease. The system is intended for use in catheterization and related cardiovascular specialty laboratories to compute and display fractional flow reserve (FFR) and resting Pd/Pa.
FFR and resting Pd/Pa supplements the visual data provided by angiography and provides an assessment of the lesion severity.
Measurement of FFR and resting Pd/Pa requires simultaneously monitoring the blood pressures proximal and distal to a lesion. The ACIST RXi System includes a single-use microcatheter with a pressure sensor for acquisition of the distal pressure. The proximal pressure is acquired via the guide catheter which is monitored by the ACIST RXi System via an interface to the hospitals hemodynamic monitor.
Pd/Pa is the ratio of distal coronary arterial pressure to aortic pressure, measured at resting conditions. The physician may then use the resting Pd/ Pa value, along with knowledge of patient history, medical expertise and clinical judgment to determine if an additional measurement of FFR during hyperemia or therapeutic intervention is indicated.
The console touchscreen is the main user interface for the ACIST RXi System and provides the following functionality:
guides the user in system operation
zeros the aortic pressure signal
equalizes the RXi pressure sensor and aortic pressure signals
adjusts the Pv value
displays the mean Pa, Pd, Pd/Pa, and FFR values
identifies the vessel
shows the last three FFR recorded values
enables access to system settings via a main menu
enables viewing the case information
calibrates the RXi Pa signal to the hospitals hemodynamic system signal
Age
Manufactured: 2016
Dimensions
Overall Dimensions: 10" wide x 9" long x 18" tall
Warranty
I stand behind everything I sell and for 30 days I guarantee this Acist RXi System Console and Mounting Accessoryis exact to the description and pictures I have provided here or return it for a refund.
Shipping
Weight before packing is 12.3 lbs for everything pictured.
All buyers may use the shipping calculator.
Pickup is always welcome from our warehouse in Coolidge Az (40 miles south of Phoenix Az near I-10).
If the shipping calculator wont give you a shipping cost you must contact me for a shipping quote.
___________________________________________________________________
"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."
Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment.. The purchaser, indicates their acknowledgment of, and agreement to the terms of this disclaimer. There are no warranties which extend beyond the description on the face hereof. This item has been cleaned and handled in accordance with the manufacturer's instructions..