DESCRIPTION
Manufacturer - Fort
Part # 1025L
SKU: 116085
Description – Fort Module 1025L small animal monitoring & gating system components (not complete system). See full system description below. Includes the Data Acquisition Module, with USB adapter and cables and oem power supply , PC In/Out Gray Blue , V3413 Cable Red/Red/Black Cabling / Thermal sensor (2) with cabling / Blue clamp cable
Mfgr System Description - The Model 1025L monitoring and gating system was designed to meet the physiological monitoring and
gating needs for anesthetized mice, rats and larger animals in the PET, CT, SPECT and laboratory environments. The system consists of a main data acquisition and processing module located near the animal and a fiber optic transceiver (FORT) Module connected to a PC located near the operator console. The PC displays multiple waveforms, measured values, trends and gating pulses. The data acquisition module iscontrolled by menu driven software from the PC. The animal’s electrocardiograph (ECG) waveform is
measured using three leads with sub-dermal needle electrodes, gold disk surface electrodes or radio translucent pads. The waveform is processed to
detect R-waves and determine the heart rate. Temperature is measured using a small rectal temperature probe. The temperature measurement can be used with the Heater System to control the temperature of the animal. Temperature variations of ±0.1 o C can typically be obtained.A respiration waveform is measured using a small pneumatic pillow placed next to the animal’s abdomen. The waveform is automatically processed to detect inspiration, expiration and respiration rate. A blood pressure waveform is measured using a pressure transducer connected with small bore tubing to an invasive line in the animal. The waveform is processed to determine systolic, diastolic and mean arterial pressure. Auxiliary input channels allow the user to acquire,
record, display and gate from user generated signals. A sophisticated user configured gating algorithm allows gates generated from each measured waveform to be combined to supply a trigger to the imager. The user
can control the start, stop and width of each gate. Power is supplied from an internal battery and/or anexternal 12 VDC power supply which operates from
100-230 VAC, 50-60 Hz. The internal battery isautomatically charged when connected to line power.
Other numbers – 91-59026 C400-10
CALL US with questions -
Thanks for looking!
Return Policy
5 Day Return Policy. Free Return. If you receive an item that it not as described, you MUST contact us by email within 5 days to explain the situation. Please provide as much detail as possible and include pictures if you can. We will return email an authorization. You MUST get the return to us within 10 days of the authorization in order to be accepted. NO returns will be accepted unless authorized in advance and the incoming parcel has the approved RMA number clearly marked on the exterior of the package. See above. All shipping is at customer expense. All authorized returns must be sent to us via UPS or FedEX as USPS does NOT deliver to our address and will return them to the sender.
If the item you are returning is not defective, and you simply don't want it, this is referred to as a 'convenience return' and there will be a restocking cost of 25% to cover the time, labor, inventory work, sales effort and so on. Please keep this in mind before you purchase an item.
NOTE - some items are NOT returnable. This will include electronic boards, memory and related components that have been installed but have not been agreed to be defective. It is expected customer will contact us to report electronic component failures and that a troubleshooting process will ensue in which our personnel will govern procedure to confirm or deny component failure. If this has not occurred, there is no case in which we will assume financial responsibility for electrical part or components.