Product details:
Manufacturer Philips
Item: Philips Intellivue MP50 Critical Care Monitor W/ NEW Leads & Modules
Model/Cat # MP50 / M8004A
Serial No. DE820A4839
Made In: Germany
Date of Manufacture: 2012-10
Voltage: 100-240V 50-60Hz 1.8-1.0A
Short description...
1. Sale is for imaged items only.
2. Signs of HIGH usage.
3. Has been tested at our end & functionality has been shown in the image section.
*CE# 0366
*Battery Status: NOT installed (Non-battery type)
*Parameters: Temp, NBP, SpO2 (Nellcor), ECG, IBP
*Options: H10 A06 C01 C15 C20 C31 YDB YDS
*Modules:
-1X M3001A MMS Module Ref 862442 (SN# DE5220EFEW | DOM: 2015-03) [Opt: A01C06]
-1X M1006A Press Module (SN# 3126A43217)
-1X M1012A CO Module (SN# 3805A22568 | DOM: 03-1998) [Opt: ABA]
-1X M1116B Print Module (SN# 4227A31627 | DOM: 2004-05) (Top cover is missing)
*Extension Modules : can be added - NOT INCLUDED
*Software: Rev J.04.98
*Printer: Installed; paper NOT included
*LCD: Responsive | Bright | Has a horizontal scratch
*Handle: Intact
*Trim knob: Working
*Softpads: Working
*Dents/Cracks: Emblem is cracked at right upper corner; see images
*Scratches/Scuffs: Yes
*Date & time: Date is correct, time can be adjusted as per the time zone
*Ports: Enjoys LAN port
*Patient Leads: (NEW | DOM: 2024)
-1X ECG Cable W/ Leads Ref SG5124S (New)
-1X NBP Hose Ref SH0910S W/ Adult Cuff Ref SC1811-11 (Both New)
-1X IBP Cable Ref SB0211, No transducers (New)
-1X Temp Probe Ref ST1305; No covers (New)
*No CO cable or transducer included
*Power Cord: Included
*Stand: Not Included
*Manual: Not Included
*Please review images & check for compatibility before bidding for the item
Package includes:-
Philips Intellivue MP50 Anesthesia Patient Monitor
M3001A MMS Module Ref 862442 | SN# DE5220EFEW
M1006A Press Module (SN# 3126A43217)
M1012A CO Module (SN# 3805A22568)
M1116B Print Module (SN# 4227A31627)
1X ECG Cable W/ Leads Ref SG5124S (New)
1X NBP Hose Ref SH0910S (New)
1X Adult Cuff Ref SC1811-11 (New)
1X IBP Cable Ref SB0211, No transducers (New)
1X Temp Probe Ref ST1305; No covers (New)
Power Cord
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
6. Sterilized : No
7. Manual : No
8. Cleaned : Yes
9. Shipping Weight : 40 lbs
Stock ID : 35204 {P.O 4014/2012} (WH104)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
1. Overall Condition: As seen in images - Good
2. Physical Condition: Please review images before bidding - Fair to Good
3. Working Condition: Has been tested at our end & functionality has been shown in the images......Will receive item as pictured…………(offered AS IS)
4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added Note:
1 .T O PURCHASE THIS ITEM THEN CLICK “BUY NOW”
2. PAYMENT MODE: PAYPAL
3. YOU DO NOT NEED A PAYPAL ACCOUNT TO MAKE PAYMENT AT PAYPAL
4. More images are available on demand
5. Warranty: 15 days money back, with in USA only. Shipping charges are NON-REFUNDABLE.
Buyer’s pay the return shipping charges
6. No warranty is being offered for AS IS – Parts only items or items with Unknown condition
7. All international sales are final!
8. Please note that shipping charges are based on weight & meant for Lower 48 US states only
9. International Customers: shipping charges would be billed separately
10. Shipping Carriers: various; client can use their own shipping!
DISCLAIMERS:
1. "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."
2. This item is Being Sold in AS IS condition & the seller assumes no responsibility for the proper or improper use of the product. If the item is to be used in conjunction with patient care and/or diagnosis, it is responsibility of the buyer to get proper certifications/licenses for the use of the item. It would be highly recommended and wise to have a bio-med completely check the product for its performance and safety parameters before actual use for patient care and/or diagnosis.
3. Medical science is an ever-changing field and Information provided, may be, outdated, partial or incomplete and may be inaccurate or useless or contain mistakes. Seller disclaims any obligation, responsibility or liability, which concerns or relates to any information, product or services and is not liable for any direct or indirect claim, loss or damage resulting from use of this product, web page and/or any web site(s) linked to/from it. It is stated that nothing on this page should be taken to constitute professional advice or a formal recommendation and seller exclude all representations and warranties relating to the contents.
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.