Over 650 Total Lots Up For Auction at Two Locations - NJ 06/15, MO 06/17

spacer
PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor
PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor PHILIPS M3535-20140 Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor

For Sale PHILIPS M3535A Defibrillator PH M3535A Power Supply Board PN M3535-20140 Monitor Parts P/N M3535-20140

  • Part Number : M3535-20140
  • Qty. Available : 20
  • In Stock : Yes
  • Date : June 03, 2026
  • Listing # : 5546492
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #5546492

  • Part #: M3535-20140
  • Description: Defibrillator PH M3535A Power Supply Board PN M3535-20140
  • Brand: PHILIPS
  • Type: Monitor
  • Warranty: 90 days
Defibrillator PH M3535A Power Supply Board PN M3535-20140 With 3 months warranty

M3535A Power Board Introduction
This board is designed to convert input AC mains power into a stable DC voltage required by various internal circuits in a device. Its core function is to reliably and safely power medical monitoring equipment.
Main Functions and Features:
Core Function:
Converts a wide range of AC input (90-264V, globally compatible) into a set of isolated, stable DC outputs (e.g., +5V, +12V, +3.3V, ±15V, etc.).
Provides clean power to the monitor's motherboard, display, backlight, and sensor modules (such as blood pressure, blood oxygen, and ECG modules).
Key Features (Medical-Grade Requirements):
High Reliability: Medical equipment requires 24/7 uninterrupted and stable operation; power supply is critical.
Low Leakage Current: Strictly adheres to medical safety standards (such as IEC 60601-1) to prevent the risk of micro-electric shock to patients.
High Isolation Rating: Strict electrical isolation barriers exist between the input (high-voltage AC) and output (low-voltage DC) circuits, as well as the patient connection points.
Overvoltage, Overcurrent, and Overtemperature Protection: Equipped with comprehensive protection circuitry, it safely shuts down in case of a fault, preventing damage to other expensive components or causing hazards.
EMC Performance: Excellent electromagnetic compatibility design, resistant to external interference and does not emit excessive electromagnetic interference that could affect other equipment.
Physical Form Factor:
A separate printed circuit board, typically containing a large heatsink, high-voltage filter capacitors, a transformer, switching transistors, and a control IC.
Connected to the mainboard and other modules via board-to-board connectors or wiring harnesses.
The board is usually clearly labeled "M3535A".
Common Faults and Symptoms: When this power board malfunctions, the entire monitor will fail to operate or will operate unstablely, specifically manifested as:
Completely Unresponsive: No indicator lights illuminate when the power button is pressed, and the screen remains dark.
Unable to Power On: A slight sound is heard or the indicator light flashes briefly before the monitor shuts down.
Intermittent restart: The device suddenly loses power and then restarts during operation.
Specific function failure: An abnormal voltage output on a certain circuit causes a module (such as blood oxygen or blood pressure) to malfunction.
Blown fuse: An internal short circuit causes the input fuse to blow.
Important Precautions (Maintenance Related): High Voltage Hazard: This board is directly connected to AC mains power. Even after power is cut off, potentially lethal charges may remain on its high-voltage capacitors. Non-professionals should never attempt to disassemble or repair it.
Summary: The Ph M3535A is a crucial switching power supply board within Philips medical devices, meeting stringent medical safety standards. Its design goal is to safely, reliably, and uninterruptedly power life-monitoring equipment; its reliability is directly related to patient safety.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Guangzhou YIGU Medical Equipment Service Co,. Ltd
profile image
Shop with confidence
Send the Seller a message: