Philips Ingenia 1.5T Mobile MRI System – 2013 MRI / 2016 Trailer
Condition: Excellent, fully functional Location: United States Availability: Ready
for inspection or shipment
System Overview This mobile MRI system combines a 2013 Philips Ingenia 1.5T 16-channel MRI with
a 2016 Kentucky-style mobile trailer. The system is in excellent condition, fully functional, and ready for
redeployment. Designed for flexibility, it is suitable for fixed-site overflow, mobile service routes, or as a
temporary replacement during facility upgrades.
MRI System Details • Manufacturer: Philips • Model: Ingenia 1.5T • Year of Manufacture: 2013 •
Channels: 16 • Software Version: 5.7 • Field Strength: 1.5 Tesla • Configuration: Standard Philips
imaging package • Included Coil: Anterior Torso Array • Note: Coil configuration package (e.g., neuro,
MSK, cardiac, body) must be purchased separately based on imaging needs • Features: - CINE
Protocol Package - fSENC Cardiac Package - ECG Triggering - Fully digital dStream architecture
Mobile Trailer Specifications • Trailer Year: 2016 • Type: MRI-configured Kentucky-style mobile coach •
Construction: Steel-reinforced frame with RF shielding • Shielding: - RF attenuation: 90 dB (15
MHz–128 MHz) - 5-gauss magnetic field containment • Power Requirements: - 480V A.C., 3-phase,
112.5–207.6 KVA - Fused at 150–200 amps - Frequency: 60 Hz - Connector Type: Russellstoll
#DS2504 MP000/DF2504FRAB0 - Grounding: Minimum #3/0 AWG recommended • Connectivity: -
RJ-45 CAT-5E data outlets (50’ cable) - Optional Hubbell all-weather phone connectors • Chiller/Water
Supply: - Direct water connection for humidifier (¾” hose fitting) - External chiller connections located
on forward left side
Site and Setup Requirements • Recommended concrete pad: 60’ x 18’, level within 0.125” over 10’
span • Adequate space required for patient lift, access stairs, and service doors • Firm, level surface
with unrestricted venting for helium exhaust • Single-point electrical connection with lockout/tagout
safety compliance
Included with Sale • 2016 mobile MRI trailer with 2013 Philips Ingenia 1.5T MRI • One (1) anterior torso
coil • Complete site-planning and installation reference documentation • Power and data connection
hardware as currently equipped
Not Included • Additional coil sets (can be configured upon request) • Chiller or extended cabling •
Delivery, rigging, and installation services (available as options)
Condition System is fully operational, professionally maintained, and in excellent cosmetic and
functional condition. Suitable for immediate deployment upon transport and site preparation.
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.