About This Item
Actual item from lot is shown. Used unit, tested and inspected thoroughly. Only what is shown is included. Note this system will ship on a pallet, each component packaged separately to protect them. Guaranteed functional for 30 days.
This system includes several components. See detail below. Not shown is the MyOSure Hysteroscopic Tissue Removal Control Unit, which is an option that is included in what we offer.
Know What You are Buying
We typically take the time to post actual pictures of the unit you are buying
We also typically take the time to thoroughly test the units we are selling
Buy with CONFIDENCE from a reputable seller with 25 Years experience
DESCRIPTION
Manufacturer - Hologic
Part # AQL-100BPS & MyOSure 10-550
Serial - 1902CE0752 & MyOSure H7461K18D0
About the System
The intrauterine pressure can be adjusted on the front of the pump. It can be pre-set to a range between 40 and 150 mmHg. The maximum inflow rate is 800 ml/min and is reduced automatically by the pump once the pre-set intrauterine pres-sure setting has been reached.The system has been designed to provide both fluid and vacuum systems that max-imize the performance of tissue removal systems, e.g. MyoSure.
The Aquilex Fluid Control System can be used with hypotonic, electrolyte-free me-dia (e.g., glycine 1.5 % and sorbitol 3.0 %) and isotonic, electrolyte containing media (e.g., saline 0.9 % and Lactated Ringer's).Pressure measuring and regulating The system operates with a completely non-contact pressure measurement of the irrigation medium. The contact-free pressure measurement is achieved by integrating the pressure chamber into the tubing system. The pressure chamber transmits the irrigation fluid pressure to the electronics of the device via a pressure sensor.
The pressure control circuit continuously compares the desired preset intrauterine pressure with the actual intrauterine pressure. The function of this algorithm is to maintain the pre-set intrauterine pressure. Check for possible leaks if the pre-set intrauterine pressure cannot be achieved.
Return Policy
5 Day Return Policy. Free Return. If you receive an item that it not as described, you MUST contact us by email within 5 days to explain the situation. Please provide as much detail as possible and include pictures if you can. We will return email an authorization. You MUST get the return to us within 10 days of the authorization in order to be accepted. NO returns will be accepted unless authorized in advance and the incoming parcel has the approved RMA number clearly marked on the exterior of the package. See above. All shipping is at customer expense. All authorized returns must be sent to us via UPS or FedEX as USPS does NOT deliver to our address and will return them to the sender.
If the item you are returning is not defective, and you simply don't want it, this is referred to as a 'convenience return' and there will be a restocking cost of 25% to cover the time, labor, inventory work, sales effort and so on. Please keep this in mind before you purchase an item.
NOTE - some items are NOT returnable. This will include electronic boards, memory and related components that have been installed but have not been agreed to be defective. It is expected customer will contact us to report electronic component failures and that a troubleshooting process will ensue in which our personnel will govern procedure to confirm or deny component failure. If this has not occurred, there is no case in which we will assume financial responsibility for electrical part or components.