Over 1150 Cleansweep Auctions End Today - Bid Now
Over 550 Total Lots Up For Auction at Four Locations - Over 10 California Auctions End Tomorrow 07/17 - Bid Now, VA 07/21, CA 07/22, KS 07/24

spacer
STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0
STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0 STRYKER AxSOS 5.0

For Sale STRYKER AxSOS 5.0

  • Asking Price :$2,494.99 USD [convert]
  • Condition : Used - Good
  • Est. Shipping(US) : $74.99 USD
  • Weight : 35.00 Lbs
  • Qty. Available : 1
  • In Stock : Yes
  • Date : July 16, 2026
  • Listing # : 5771465
  • credit-card
  • credit-card
  • credit-card
  • credit-card
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #5771465

  • Condition: Used - Good
  • Brand: STRYKER
  • Type: Other
  • Model: AxSOS 5.0
Device Profile
Manufacturer: Stryker
System: AxSOS™ 5.0 Locking Plate System – Distal Femur
Set Configuration: Multi-Tray Instrument System
Tray References:
• Tray 1 (Top): REF 902923
• Tray 2 (Middle): REF 902965
• Tray 3 (Bottom): REF 902964
Sterilization Case: REF 902921 (Base) / REF 902967 (Lid)
Lot Numbers: W10750 / 220101
CE Marked: Yes
Application: Orthopedic Trauma – Distal Femur Fixation
________________________________________
Short Description
Stryker AxSOS 5.0 distal femur locking plate instrument system comprising three organized instrument trays housed in an original Stryker sterilization container. The set includes drilling, aiming, fixation, and insertion instruments arranged in procedural workflow configuration. This is a near-complete system with only minor missing components.
Quick Condition Overview
Cosmetics: Very Good
Overall Condition: Very Good
Functional Status: Untested (Visual Inspection Only)
Completeness: Near Complete (See Notes Below)
________________________________________
Condition Summary
Instruments:
All instruments appear clean and well-maintained with typical signs of prior clinical use. No major corrosion, bending, or structural damage observed. Laser etching and REF markings remain visible across most components.
Trays:
Original Stryker trays are intact and properly organized. Minor cosmetic wear present consistent with normal use.
Sterilization Case:
Outer container shows moderate surface wear, scratches, and sterilization discoloration.
Latch Condition (Important):
⚠️ One lid latch clamp is broken/damaged (as shown in images). Remaining latches appear functional.
________________________________________
Functionality / Testing Summary
Visual & Mechanical Inspection:
All instruments visually inspected; moving components (handles, drivers) appear mechanically functional by hand.
Set Organization:
Set remains logically arranged tray-wise, consistent with procedural workflow:
• Drill / K-wire preparation
• Plate positioning & targeting
• Fixation & driver instrumentation
Testing Note:
No clinical or calibrated testing performed.
Instrument Tray Breakdown
________________________________________
Tray 1 – Drilling & K-Wire Preparation (REF 902923)
• REF 702884 – Direct Depth Gauge
• REF 702703 – K-Wire Sleeves (Qty: 3)
• REF 702708 – Drill Sleeves (Qty: 3)
• REF 702748 – Screwdriver (T20)
• REF 702429 – Large Teardrop Handle
• REF 702751 – Torque Limiting Attachment
• REF 702733 – Screwdriver Holding Sleeve
• REF 702773 – Tap
• REF 702754 – T20 Screwdriver Bits (Qty: 2)
• REF 702743 – Drill Bit (Qty: 1; one likely missing)
• REF 702712 – Drill / K-Wire Measure Gauge
• REF 390191 – 2.0 mm K-Wires (Qty: 4)
________________________________________
Tray 2 – Plate Positioning & Aiming (REF 902965)
• REF 702782 – Soft Tissue Elevator
• REF 702776 – Temporary Plate Holders (Qty: 2)
• REF 702768 – Locking Insert Extractor
• REF 702763 – Locking Insert Inserter
• REF 702778 – Handle for Plate Insertion
• REF 702791 – Plate Trial / Shaft Hole Locator
• REF 702718 – Right Aiming Block (Distal Femur)
• REF 702719 – Left Aiming Block (Distal Femur)
________________________________________
Tray 3 – Fixation / Drill Guides & Specialty (REF 902964)
• REF 702417 – Double Drill Guide
• REF 702822 – Drill Sleeve Handle
• REF 702839 – Buttress Drill Sleeve
• REF 702824 – Neutral Drill Sleeve
• REF 702823 – Compression Drill Sleeve
• REF 702958 – Percutaneous Neutral Drill Sleeve
• REF 702672 – Guide for Centering Pin
• REF 702710 – Percutaneous Drill Sleeve
• REF 702843 – 3.5 mm Hex Screwdriver
• REF 702674 – Centering Pin
• REF 702862 – Screwdriver Holding Sleeve
• REF 700357 – Drill Bit (Qty: 1; one likely missing)
• REF 702877 – Direct Depth Gauge
• REF 702430 – Medium T-Handle
• REF 702962 – Trocar
• REF 702969 – Locking Insert Forceps
________________________________________
Flip-Up Compartment (Tray 3 Subsection)
• REF 702853 – 3.5 mm Driver
• REF 702807 – 6.5 mm Tap
• REF 702806 – 4.5 mm Tap
• REF 700354 – 4.5 mm Drill Bits (Qty: 2)
• REF 390192 – 2.0 mm K-Wires
________________________________________
❗ Missing / Noted Items
• ❗ REF 702918 – Soft Tissue Spreader (Missing)
• ❗ One drill bit in Tray 1 appears missing (REF 702743 set incomplete)
• ❗ One drill bit in Tray 3 appears missing (REF 700357 set incomplete)
• ⚠️ One sterilization case latch is broken
________________________________________
What Is Included
• Complete 3-tray Stryker AxSOS 5.0 instrument system
• Original Stryker sterilization container with lid
• All instruments shown in images
What Is Not Included
• Soft Tissue Spreader (REF 702918)
• Implants, plates, or screws
• OEM manuals or documentation
Buyer Advisory Note
This is a used orthopedic surgical instrument system being sold in near-complete condition. Minor components are missing and one latch is damaged. Buyer is responsible for verifying completeness and suitability for intended use. Biomedical inspection and sterilization are recommended prior to clinical application.
Shipping Note
This is a large and heavy surgical instrument set and will be professionally packaged. Freight or reinforced packaging may be required depending on destination.
________________________________________
🔴 Stock ID: 39362 (P.O. 1200) (R3 C16)
Purchase Terms & Buyer Protections
Condition & Use Notice
Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.
ADDED NOTE:
1. IF YOU WANT TO PURCHASE THIS ITEM THEN CLICK “BUY NOW”
2. PAYMENT MODE: PAYPAL
3. YOU DO NOT NEED A PAYPAL ACCOUNT TO MAKE PAYMENT AT PAYPAL
4. More images are available on demand
5. Warranty: 15 days money back, with in USA only. Shipping charges are NON-REFUNDABLE.
Buyer’s pay the return shipping charges
6. No warranty is being offered for AS IS – Parts only items or items with Unknown condition
7. All international sales are final!
8. Please note that shipping charges are based on weight & meant for Lower 48 US states only
9. International Customers: shipping charges would be billed separately
10. Shipping Carriers: various; client can use their own shipping!
DISCLAIMERS:
1. "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."
2. This item is Being Sold in AS IS condition & the seller assumes no responsibility for the proper or improper use of the product. If the item is to be used in conjunction with patient care and/or diagnosis, it is responsibility of the buyer to get proper certifications/licenses for the use of the item. It would be highly recommended and wise to have a bio-med completely check the product for its performance and safety parameters before actual use for patient care and/or diagnosis.
3. Medical science is an ever-changing field and Information provided, may be, outdated, partial or incomplete and may be inaccurate or useless or contain mistakes. Seller disclaims any obligation, responsibility or liability, which concerns or relates to any information, product or services and is not liable for any direct or indirect claim, loss or damage resulting from use of this product, web page and/or any web site(s) linked to/from it. It is stated that nothing on this page should be taken to constitute professional advice or a formal recommendation and seller exclude all representations and warranties relating to the contents.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Medicka
448 Items sold with Buy It Now
Shop with confidence
GSG Capitalspacer
Send the Seller a message: