Over 1600 Total Lots Up For Auction at Four Locations - NJ Cleansweep 05/07, NJ Cleansweep 05/08, CA 05/09, CO 05/12

spacer
MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray
MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray MINXRAY HF100H+ Portable X-Ray

For Sale MINXRAY HF100H+ Portable X-Ray

  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : April 21, 2025
  • Listing # : 4914931
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4914931

  • Condition: Used - Good
  • Brand: MINXRAY
  • Type: Portable X-Ray
  • Model: HF100H+
  • Kv Range: 40-100 kVDC
  • Ma Range: 20-30 mA
  • Mas Range: 0.6 - 120
  • Tube Year: 2015
MinXray HF100H+
High Frequency Portable X-ray Unit with stand

Specifications:
Construction: Monobloc HF generator, full bridge inverter
Output: 30 mA @ 40-60 kVDC,
25 mA @ 62-80 kVDC,
20 mA @ 82-100 kVDC
kVDC Steps: 2KV intervals
mAs: 0.6 - 120
Timer: Ultra High Resolution 0.03-4.0 sec, 0.01 increments
X-Ray Tube: Toshiba D-124S
Focal Spot: 1.2 mm
Anode Heat Storage: 20 kHU
Total Filtration Incl. Collimator: 3.8 mm AI equivalent
Inverter Frequency: 60 kHz High Frequency
Line Voltage: AC Single Phase 100 - 140 V; 50/60 Hz
Fuse Rating: 30 amp @ 125 kV
Electrical Consumption: 20 amp @ 125 kV
Maximum Consumption: 2.0 kW @ 100 kVDC, 20 mA
Tubehead Dimensions: 11.5" x 9.1" x 17.7" (29.2 x 23 x 45 cm)
Tubehead Weight: 44.5 lb. (20.2 kg)
Collimator: Continuously adjustable light beam type with central x-ray indicator
Power Cord: 20 ft. (6.1 m)
Exposure Switch: Two-stage, deadman with RJ11 connector
Exposure Cord: 12 ft. (3.66 m)
Compatibility: All film and digital capture systems

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Chicago Medical Engineering
Shop with confidence
Citi Capital Groupspacer
Moveitem Shippingspacer
Send the Seller a message: