For Sale POCVODA PV-301A Pump IV Infusion

  • Asking Price :$290.00 USD [convert]
  • Condition : New
  • Qty. Available : 1
  • In Stock : Yes
  • Date : June 08, 2024
  • Listing # : 3591497
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #3591497

  • Condition: New
  • Brand: POCVODA
  • Type: Pump IV Infusion
  • Model: PV-301A
  • MPN: PV-301A
  • Warranty: 2 years
The Features:
1. Designed to fully comply with IEC60601
2. Controlled by Dual-CPU
3. Automatically self-defined size of syringe: 5ml, 10ml, 20ml, 30ml, 50/60ml.
4. Drug-weight mode, programming function and Bolus mode available
5. Drug Library: Build-in 48 drugs and could expand to thousands
6. Event Record function
7. Anti-Bolus function
8. Occlusion pre-alarm
9. Key lock function
10. Preset 8 syringe brands, new brand can be user-defined.
11. Piggyback function is available
12. Pressure auto release function when occlusion occurs, reducing potential risk.

Syringe Size: 5ml,10ml,20ml,30ml,50ml

Injection Mode
Normal mode, Time Mode, Programming Mode, Weight mode and
Drug Library Mode

Accuracy Error Rate ±2% (mechanical precision ±1%), < 1ml/h ±5%

Flow Rate Range
5ml syringe: 0.1~150.0ml/h
10ml syringe: 0.1~300.0ml/h
20ml syringe: 0.1~400.0ml/h
30ml syringe: 0.1~600.0ml/h
50ml/60ml syringe: 0.1~1200.0ml/h (step 0.1ml/h)

VTBI 0.1-9999.9ml (step0.1ml)

Total Volume Range 0-9999.9ml (step 0.1ml)

KVO 0.1-20.0ml/h ; Default:1ml/h

Purge
5ml syringe: 150.0ml/h
10ml syringe: 300.0ml/h
20ml syringe: 400.0ml/h
30ml syringe: 600.0ml/h 50ml/60ml syringe: 1200.0ml/h

BOLUS
1. Rate & Volume could programming while pumps working;
(Default: 600ml/h ,VTBI:2ml)
2. Bolus rate is followed the last setup with no limited of VTBI.
(Default: 600ml/h)

Occlusion Pressure
High: (80±10) kPa
Mid : (60±10) kPa
Low: (45±10) kPa

Occlusion pre-alarm
When monitoring the pressure on the high side, Occlusion
pre-alarm

Alarm
Near empty of syringe, under-voltage battery, power interruption,
wrong installation of push-handle clip, wrong installation of
compressive bar, wrong installation of pushing bar, end of infusion,
suspension time-out, pushing of empty syringe, abnormal power
supply, system mistake, internal communication mistake,
abnormal speed, occlusion pre-alarm syringe occlusion alarm,
battery running-out, battery damage

CPU Dual-CPU

Lock Key Key Locking to avoid carelessness the parameter

Fast Start Overcome dose delay

Anti-Bolus Back off system to reduce pressure and quick release of occlusion

Drug Library
Build-in 48 drugs and could expand to thousands if customer
needed.

Piggyback Do not need stop the pump to change the parameters directly.

Programmable Maximum 8 integrates infusion

History Records
1500 event records, 200 modified records,Historical record can be
check in the machine directly
Records can be exported in LAN.

Power Supply AC100V~240V,50Hz/60Hz ,15VA

Battery
Ni-MH battery, DC9.6V, 2000mAh; fully-charged battery can be
used for over 7 hours at a speed of 5ml/h;

Display Industrial-grade true color display

Installation Desktop, transverse, longitudinal

Electrical Safety Classification Class I with inner power, IPX4, CF

Dimension 140mm×145mm×325mm(D x H x L)

Net Weight 1.9Kg

Operation Condition
Temperature: 5°C ~ 40°C;Relative humidity: 20% ~ 90%
Atmospheric pressure: 70 ~ 106kPa

Application Applicable for intravenous injection

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Tags: IV Infusion Pump
Seller Information
This user has not been rated
  • Location :China CN flag
small ad
spacer
Adepto Medical is an infusion pump rental, sales, and service company. Our focus is to deliver to our customers the best product and customer service support we can offer. Call (913) 261-9933
stats
Citi Capital Groupspacer
Send the Seller a message: