The Features:
1. Designed to fully comply with IEC60601
2. Controlled by Dual-CPU
3. Anti-reverse function on motor to prevent upstream
4. Occlusion Pre-alarm
5. Key lock function
6. Drug Library: Build-in 48 drugs and could expand to thousands
7. Events record system
8. Advanced Deviation Control of infusion, in volumetric mode ≤±3% (after calibration), in
drip-rate mode ≤±1.5%
9. Drug-weight mode, programming function and Bolus mode are available
10. Stand-by function
11. Piggyback function is available
12. Tube locking for optional
13. Warmer for optional
IV Set Options /Size
1. Drop Mode:Open System with IV set of
10d/ml,15d/ml,20d/ml,60d/ml. (3.4mm~4.5mm)
2. Volume mode:Can use any tube type, brand standard infusion。
(3.4mm~4.5mm)
3. Also can be customized for Dedicated IV set
Infusion Mode
Drop mode/Volume mode, Normal mode, Rate/Time, Programming
mode ,Durg-Weight mode, Drug library mode, Micro mode
Accuracy Error Rate after calibration:≤±3%
Flow Rate Range
20d/ml IV set: 0.1~1200ml/h
60d/ml IV set: 0.1~150ml/h
Micro mode: 0.1~100ml/h (Step: 0.1 ml/h)
Drip Rate Range
10 d/ml IV set: 1.0 ~ 200 d/min
15 d/ml IV set: 1.0 ~ 300 d/min
20 d/ml IV set: 1.0 ~ 400 d/min
60 d/ml IV set: 1.0 ~ 150 d/min
VTBI 1~9999ml
Total Volume Range 0~9999ml
KVO 1-20ml/h Adjustable Default: 1ml/h
Purge 600ml/h
BOLUS
1. Rate & Volume could programming while pumps working.
(Default: 600ml/h ,VTBI:2ml)
2. Bolus rate is followed the last setup with no limited of VTBI.
(Default: 600ml/h)
CPU Dual-CPU
Bubble Detection Detected by ultrasonic with adjustable setting, 50 ~ 800μL.
Occlusion Pressure
Upper occlusion detected; Down occlusion: High 70-90kPa; Mid
55-70kPa; Low 40-55kPa
Occlusion Pre-alarm
When monitoring the pressure on the high side, Occlusion
pre-alarm
Alarm
Bubbles, Door open, Finished, Pause overtime, Leakage, Empty,
Battery under voltage or damage, Motor reverse, Incorrect IV
tube-type setting, Pressure test failure, Motor failure, Abnormal drip
sensor, Abnormal drip rate, Heater failure, Down occlusion, Up
occlusion, Internal communication fail, Down occlusion pre-alarm.
Anti-reversal Infusion Anti-reverse function of motor to prevent upstream
Lock Key Key Locking to avoid carelessness the parameter
Stand-by Function Yes, 1min to 24h for standing by
Programmable Maximum 8 integrates infusion
Drug Library
Build-in 48 drugs and could expand to thousands if customer
needed.
History Records
1500 event records , 200 modified records,Historical record can be
check in the machine directly.
Records can be exported in LAN.
Piggyback Do not need stop the pump to change the parameters directly.
Power Supply AC100V~240V,50Hz/60Hz ,15VA Battery
Ni-MH battery, DC9.6V, 2000mAh; fully-charged battery can be used
for over 4 hours at a speed of 5ml/h.
Display Industrial-grade true color display
Installation Desktop, transverse and longitudinal
Electrical Safety Classification Class I with inner power, IPX4, CF
Fluid Warmer (Optional)
Relieve uncomfortable condition such as pain, vessel convulsion,
shiver when transfuse cold fluid.
Tube Locking Yes for optional
Dimension 130mm×120mm×195mm (D x H x L)
Net Weight 2.0Kg
Operation Condition
Temperature: 5°C ~ 40°C; Relative humidity: 20% ~ 90%;
Atmospheric pressure: 70 ~ 106kPa
Applicability Micro or rapid Intravenous infusion for various fluid medicine
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.
Tags:
IV Infusion Pump