p dir="ltr">Riello SENTINEL Pro Dual 1.5 kVA Double Conversion On-Line UPS
<
Rated at 1500VA/1350W
<
Runtime: 6 minutes at full load
<
Model: SEP 1500
<
Configuration: Input 220/230/240V, Output 220/240V, 60Hz
<
Dimensions (WxDxH inches): 6.22x16.6x9.25
<
Weight 32.6 lbs.
<
Battery Extension Cabinet for Riello SD-UL Series UPS
<
Includes: (6)-7Ah batteries
<
Runtime: 22 minutes at full load
<
Dimensions: 3.4''(2U)x16.73''x17.24''
<
Weight: 45 lbs.
<
Sentinel Pro has a unique, modern design
<
and improved performance created by
<
the Riello UPS research and development
<
team. Sentinel Pro uses ON LINE double
<
conversion technology, resulting in the
<
highest levels of reliability and maximum
<
protection for critical loads such as servers,
<
and IT and voice/data applications.
<
For business continuity applications
<
requiring long battery runtimes, battery
<
autonomy can be extended up to several
<
hours using ER models fitted with more
<
powerful battery chargers.
<
The front display panel has been entirely
<
redesigned, adding an LCD display that
<
shows the input and output voltages,
<
battery readings and UPS operating
<
status information. The inverter and the
<
microprocessor control stage has been
<
completely redesigned to provide increased
<
efficiency and greater configuration options.
<
Maximum expandability: the Sentinel Pro is
<
supplied as standard with a USB port and
<
an expansion slot for protocol conversion or
<
relay contacts boards.
<
With energy savings in mind, Sentinel Pro
<
is also fitted with a shut-off button to
<
reduce energy consumption to zero during
<
prolonged periods of inactivity (ECO LINE).
<
Sentinel Pro is available in 700 VA, 1000 VA,
<
1500 VA, 2200 VA and 3000 VA models.
<
OPERATING FLEXIBILITY
<
Different operating modes are available
<
to reduce energy consumption based on
<
specific load and user requirements.
<
ON LINE: maximum load protection and
<
output voltage waveform quality;
<
ECO Mode: the UPS uses LINE
<
INTERACTIVE technology, with the
<
www.rielloupsamerica.com 27
<
load powered by the mains, reducing
<
consumption and thus improving
<
efficiency (up to 98%);
<
SMART ACTIVE Mode: the UPS
<
automatically selects ON LINE or LINE
<
INTERACTIVE operation, depending on
<
the quality of the mains supply, checking
<
the number, frequency and type of
<
disturbances present;
<
STANDBY OFF: the UPS supplies the load
<
only when the mains fails. The inverter
<
begins working with a progressive start up
<
sequence to prevent inrush currents.
<
Frequency converter operation (50 or
<
60 Hz).
<
EMERGENCY FUNCTION
<
This configuration ensures the operation of
<
emergency systems that must be supplied
<
in the event of a mains power failure,
<
such as emergency lighting, fire detection/
<
extinguishing systems and alarms.
<
When the mains power supply fails, the
<
inverter begins powering the loads with a
<
progressive start up (Soft Start) in order to
<
prevent overload.
<
Sentinel Pro is compliant for installation
<
in medium-voltage transformer rooms in
<
accordance with applicable legislation, for
<
the power supply with reserve charge of
<
medium-voltage coils.
<
BATTERY OPTIMISATION
<
The Sentinel Pro range has a deep
<
discharge protection device to optimise
<
battery life. Periodically the UPS carries out
<
a battery efficiency test (which can also be
<
manually activated); its wide input voltage
<
tolerance range helps to reduce battery
<
usage and maintain performance over time.
<
RUNTIME EXPANDABILITY
<
Optional battery extension packs can be
<
connected to increase UPS runtime. In
<
addition the Sentinel Pro range includes
<
ER versions with no internal batteries and
<
more powerful battery chargers for longer
<
runtimes.
<
LOW NOISE LEVEL
<
Thanks to the use of high frequency
<
components and load-based fan speed
<
control, the noise produced by the UPS is
<
less than 40 dBA.
<
FEATURES
<
Filtered, stabilised and reliable voltage:
<
double conversion ON LINE technology
<
(VFI compliant with IEC 62040-3) with
<
filters for the suppression of atmospheric
<
disturbances;
<
High overload capability (up to 150%)
<
Programmable Auto-restart when mains
<
is restored;
<
Battery start up (Cold Start);
<
Power factor correction (UPS input power
<
factor, close to 1);
<
Wide input voltage tolerance range
<
(from 140 V to 276 V) without battery
<
intervention;
<
Runtime extendable up to several hours;
<
Fully configurable using UPS Tools
<
configuration software;
<
Highly reliable batteries (automatic and
<
manually-activated battery test);
<
High level of UPS reliability (total
<
microprocessor control);
<
Low impact on the mains (sinusoidal take
<
up).
<
ADVANCED COMMUNICATIONS
<
Multi-platform communication for
<
all operating systems and network
<
environments: PowerShield3 supervision
<
and shutdown software for Windows
<
operating systems 11, 10, 8, Server 2022,
<
2019, 2016 and previous versions, Windows
<
Server Virtualization Hyper-V, macOS,
<
Linux, Citrix XenServer and other Unix
<
operating systems;
<
UPS Tools configuration and
<
customisation software supplied as
<
standard;
<
RS232 serial port and opto-isolated
<
contacts;
<
USB port;
<
Slot for communications boards.
<
1-YEAR WARRANTY
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.