Over 1600 Total Lots Up For Auction at Four Locations - NJ Cleansweep 05/07, NJ Cleansweep 05/08, CA 05/09, CO 05/12

spacer
RIELLO SENTINEL RT Uninterruptible Power Supply / UPS RIELLO SENTINEL RT Uninterruptible Power Supply / UPS RIELLO SENTINEL RT Uninterruptible Power Supply / UPS RIELLO SENTINEL RT Uninterruptible Power Supply / UPS
RIELLO SENTINEL RT Uninterruptible Power Supply / UPS RIELLO SENTINEL RT Uninterruptible Power Supply / UPS RIELLO SENTINEL RT Uninterruptible Power Supply / UPS RIELLO SENTINEL RT Uninterruptible Power Supply / UPS

For Sale RIELLO SENTINEL RT Uninterruptible Power Supply / UPS

  • Asking Price :$3,500.00 USD [convert]
  • Condition : New
  • Weight : 90.00 Lbs
  • Qty. Available : 1
  • In Stock : Yes
  • Date : April 04, 2025
  • Listing # : 5025441
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #5025441

  • Condition: New
  • Brand: RIELLO
  • Type: Uninterruptible Power Supply / UPS
  • Model: SENTINEL RT
  • Height: 12 inches
  • Length: 24 inches
  • Width: 24 inches
br>
Riello SENTINEL RT Dual 1.5 kVA Rack/Tower On-Line UPS

Model: SDH 1500 RT

Configuration: 120V

input & output @60 Hz with internal battery

Dimensions (WxDxH inches) 3.42x16.73x17.71

Weight 39.68 lbs.

Battery Extension Cabinet for Riello SD-UL Series UPS

Includes: (6) 7Ah batteries (Runtime: 22 minutes at full load).

DIM: 3.4''(2U)x16.73''x17.24''

Weight: 45 lbs.

Netman 104 Interface Card

NetAgent SNMP

(Firmware: 3.8.DA806.RPS)

Rack mounting Kit

SENTINEL RT is the high density version of the Premium Pro range of double-conversion ON LINE UPS.

SENTINEL RT is designed to power critical loads such as servers, storage systems, equipment, medical systems and industrial applications.



The UPS is ideal for Blade servers with an input power factor close to Unity (1). The UPS has can be used as tower UPS or within a rackmount cabinet, and takes up only 2U in height.

SENTINEL RT has a modern design, choice of functional formats, and represents the state-of-the-art technology from the Riello UPS research & development team. The UPS can achieve an ON LINE operating efficiency of 92%. For critical business continuity applications requiring long runtimes, SENTINEL RT can be installed with battery extension packs.

The UPS also incorporates the Riello UPS power-off function found in other ECO Line UPS. SENTINEL RT is designed to save energy when no loads are connected.

HIGHLIGHTS

Power factor 1 kW = kVA

Simplified installation

High quality output voltage

High battery reliability

Sentinel RT is designed to power critical

loads such as servers, storage systems,

telephone equipment, medical systems and

industrial applications.

The UPS is ideal for Blade servers with an

input power factor close to Unity (1). The

UPS has can be used as tower UPS or within

a rackmount cabinet, and takes up only 2U

in height.

Sentinel RT has a modern design, choice

of functional formats, and represents the

state-of-the-art technology from the Riello

UPS research & development team.

The UPS can achieve an ON LINE operating

efficiency of 92%. For critical business

continuity applications requiring long

runtimes, Sentinel RT can be installed with

battery extension packs.

The UPS also incorporates the Riello UPS

power-off function found in other ECO

Line UPS. SENTINEL RT is designed to save

energy when no loads are connected.

SIMPLIFIED INSTALLATION

Tower or Rackmount UPS: SENTINEL RT can

be installed as tower or 19 rack mount UPS,

with a front mimic panel that can be turned

through 90 to suit the installation.

Noise Free Operation (<40 dBA): the UPS

can be installed in any environment

thanks to its PWM digitally-controlled high

frequency inverter;

High Temperature Operation: UPS

components are sized for high

temperature operation up to 104 F (40 C)

and are not therefore stressed during

normal operational environments.

REDUCED MANAGEMENT COSTS

SENTINEL RT can be programmed remotely

via software or set manually from the front

mimic panel to operate in a range of energy

saving operating modes:

ON LINE: maximum power protection

and output voltage waveform quality

(efficiency up to 92%);

ECO Mode: to increase efficiency (up to

to 98%), allows for the selection of LINE

INTERACTIVE technology (VI) to power low

priority loads from the mains supply;

SMART ACTIVE: the UPS automatically

decides upon the operating mode (VI or

VFI) based on the quality of the mains

power supply;

STANDBY OFF: the operating mode in

which the UPS functions as an emergency

device. While power is present the UPS

does not intervene. In the event of a

blackout, the necessary power is provided

by the UPS.

OTHER FEATURES

Output voltage can be selected using

display;

Auto-restart when mains power returns

(programmed via software);

Standby on Bypass: when the machine

is switched off, it automatically goes into

bypass operation with batteries charging;

Power-Off with zero load connected to

save energy;

Low battery warning;

Power-on delay;

Full microprocessor control;

Automatic bypass without interruption;

Status, measurements and alarms

available on the front panel mimic panel

and LCD;

UPS firmware upgrade via PC;

Input protection including a user reset

thermal switch (up to 1500VA);

Back-feed protection;

Manual option to switch to bypass.

ADVANCED COMMUNICATIONS

SENTINEL RT offers maximum flexibility

for integrations with any communication

system.

Multi-platform communication for

all operating systems and network

environments: PowerShield3 supervision

and shutdown software for Windows

operating systems 11, 10, 8, Server 2022,

2019, 2016 and previous versions, Windows

Server Virtualization Hyper-V, macOS,

Linux, Citrix XenServer and other Unix

operating systems;

RS232 serial port and opto-isolated

contacts;

USB port;

Slot for TCP/IP, SNMP communication card.

UNITY POWER FACTOR*

More power delivered;

More real output power (W).

HIGH QUALITY OUTPUT VOLTAGE

Even with non-linear loads (IT loads with a

crest factor of up to 3:1);

High short circuit current on bypass;

High overload capacity: 150% by inverter

(even with mains failure);

Filtered, stabilised and reliable voltage

(TRUE-ON LINE double conversion

technology), with filters for the

suppression of atmospheric disturbances;

Power factor correction: UPS input power

factor close to 1 and sinusoidal current

uptake.

HIGH LEVELS OF BATTERY RELIABILITY

Automatic and manual battery tests;

Batteries are hot-swappable and user

replaceable.

EMERGENCY FUNCTION

This configuration ensures the operation

of those emergency systems that require

continuous, reliable and long-lasting power

supply in the event of a mains power failure,

such as emergency lighting, fire detection/

extinguishing systems and alarms.

When the mains power supply fails, the

inverter begins powering the loads with a

progressive start up (Soft Start) in order to

prevent overload.