Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Seller assumes all responsibility for this listing..
Listing: #5585842
1. SK-950C adopt optical gradual coating technology. to obtain International standard luminance brightness
0~10000asb(0- 51db) by precise controlling the optical lens transmittance, ensure the brightness of each
dots are full compliance with the International standard.
2. While power up system, perimeter software will get the digital calibrated array mode of optical gradual lens
and coated lens by actinoscope on the optical projection head, to make sure the initial projection brightness standard wont be changed by unstable Environmental voltage and bulb decay, It can ensure that all the medical measured data is under the international standard brightness which is accuracy.
Excellent Test Strategy DesignedThe designed test strategy shorten testing duration and improve the accuracy of result which was considered the greatest possibility of the different age range,responsiveness, visual field loss, and distribution regularities of vision island.
Kinetic testSoftware control+ Imaging Diaphragm + the movement of projection head in kinetic testing can guarantee the luminance of projection spot wont be abnormal and unfocus while projection distance changes.
Optical Coating Design With TurnplateTo guarantee the wavelength of projection spot conform to the International standard.
Red light 610nm
Blue light 440nm
White light 580nm
Five Apertures Design With Focusing Turnplate1. Standard Cora projection system, projection light without chromatic aberration.
2. To guarantee the projection light is clear and well focus while projection on aspheric surface, projection spot
with even light without scattering.
Blue-Yellow DetectionGoldman V blue projection aperture with 440mm wave length realize by optical coating technology. Standard yellow Background luminance realize by Shou OG530 filter.
Auto Eye MonitoringAdopt focusing infrared light to auto monitor eye position, while patient eye minor movement,software will
give commands to make the head &chin rest calibrate eye position automatically, it can significantly reduce
possibility of the inaccurate test result which was influenced by the uncooperative patient.
Three-Dimensional Fixation MonitorProjecting Infrared light into pupil of detected eye in X-Y-Z direction, to get the accurate Gaze Tracking Curve which support judging the credibility of patient report.
Quantitative Evaluate the Retina Macula Function( Special option for Retinal Surgery Expert)Quantitative measure the visual acuity of center retina macula and nearby. Quantitative evaluation the retinal
surgery, visual impairment and rehabilitation progress.
Technical Data