The OM-1850 Operation Microscope is a portable microscope. Its small and portable machine body makes it highly agile. It fills all the requirements to be used in a general ophthalmic micro-surgery.
The microscope is a single binocular with three magnification steps, which offers a sharp image and a large field of vision. A cold light source is used in the ilumination system, and it is harmless to the eye.
A spring balance system is designed for the arm so that the microscope can be moved up and down at any desired position.
Fine focusing adjustment can be performed.
Specifications
Parameter of Microscope
Focus length of objective: f = 200mm
Eyepieces: 12.5X / 16B
Magnification & visual field
Objective focus: F200
Total magnification: 5.3X, 8X, 12X
Visual field (mm): ¥Õ38, ¥Õ25, ¥Õ17
Illumination field (mm): ¥Õ40
Working distance
190mm
Parameter of Binocular tube
Inclined binocular Tubes: 45¨¬
Diopter adjustment range: ¡¾6D
Pupil distance range: 50mm ~ 70mm
Height of eyecups: 18mm
Parameter of illumination
6¨¬+0¨¬ Coaxial
illumination
Maximum intensity: 30000 Lx or up
Parameter of Position adjustment
Maximum stretching radius of arm: 870mm
Vertical movement range (from floor to front surface of big objective): 700mm ~ 1100mm
Range of fine focusing adjustment: 30mm
Parameter of Electic
Input voltage: AC220V ¡¾10%/50Hz ¡¾ 1%, or
AC110V ¡¾ 10%/50Hz ¡¾ 1%
Input power: 120VA
Fuse: T type AC250V 1.25A, T type AC125V 2.5A
(For example 51S-013H, 51S-025SL)
Bulb: 12V/100W (Medical halogen lampBulb with cold reflection)
Electrical safety: Conform to standard IEC601 - 1 Type I,
Name and use components
- Foot control switch
It is used to control the focusing functions.
- Spare bulb module
If a bulb gets burnt, the spare bulb module can be inserted to continue with the operation.
- Bulb module
- Diopter adjusting ring
To adjust ocular diopter by rotating this ring.
The range of adjustment is ¡¾6D.
- Eyecups
It is used to adjust exit-pupil distance. Its height
is 18mm and it may be taken off or rolled down.
- Magnification knob (with sterilized cap)
Three magnification steps are provided. The magnification factor of each step changes with the different objectives. The magnification can be modified by rotating the knob.
- Manipulating handle (with sterilized cap)
For rough focusing, move the microscope up and down or right and left.
- Fiber optic
Lead the light beam from the bulbs to the operating position.
|
|
DOTmed's COMPLIANCE NOTICE AND COMPLIANCE COMPLAINT PROCEDURE.
|