Listing: #5541577
Includes:
The DxC 500 AUanalyzer delivers the efficiency you need to make the most of your busy day. Anintuitive interface, clear task indicators, on-the-fly loading, andstandardized assays & reagents make it easy to use, so your team can devotetheir energy where its needed most.
Optimize youroperations, protect your productivity, and trust your results with a chemistryanalyzer that has a throughput of up to 400 photometric tests per hour and upto 800 tests per hour with ISE, automated HbA1c Advanced, 76 reagent positions,and high-performing Six Sigma chemistry assays.
Features:
High throughput: Capable of up to 800 tests per hour when including ISEs.Manufacturer
Beckman Coulter
Analytical method
Fully automated, random-access clinical chemistry system with STAT capability
Analytical principles
Spectrophotometry and potentiometry Assay types
Assay types
Endpoint, rate, fixed point and indirect ISE
Chemistry menu capacity
>135 preprogrammed, photometrics currently available (including LIH + HbA1c (Thb, HbA1c + HbA1c%) and ISE
Throughput
400 photometric tests per hour, up to 800 with ISE ISE maximum test per hour: 600 if ISE only HbA1c maximum tests per hour: 65 if HbA1c only
Sample types (assay dependent)
Serum, Plasma, Urine, CSF, Whole blood
Sample management/capacity
168 sample tubes (24 racks of 7 tubes), unique continuous loading feature Refrigerated STAT carousel: 22 samples can be run simultaneously (cal, QC and routine samples)
Sample container sizes
Primary and secondary tubes: diameter between 11.5 mm and 16 mm; height between 55 mm and 102 mm; nested micro cups and sample cups
Sample volume
1.0 L-25 L in 0.1 L increments (assay dependent)
Sample Barcode symbology
NW7, EAN13, CODE 39, CODE 128, ISBT-128, 2 of 5 standard, 2 of 5 interleaved mixed readable (max. six types at the same time, except if using ISBT-128)
Compartment temperatures
STAT wheel: 39.2F to 50F (4.5C to 12C) Reagent compartment: 39.2F to 50F (4.5C to 12C)
Reagent storage capacity
76 positions in a single reagent carousel (refrigerated between 39.2F (4C) and 53.6F (12C); bottle sizes: 15 mL, 30 mL, 60 mL
Barcoded reagents
Automatic tracking of: Available tests, Expiration date, Lot number
Reagent volume
10 L-250 L (1 L increments)
Total reaction volume
90 L-350 L
Reaction cuvette
Permanent glass cuvettes
Reaction time
Up to 8 minutes, 37.5 seconds
Reaction temperature
98.6F 0.5F (37C 0.3C)
Reaction incubation method
Dry bath
Photometric range
0 OD-3.0 OD
Wavelength
13 different wavelengths between 340 nm and 800 nm
Automated sample pre-dilution
Repeat run with increased or decreased sample volume or sample pre-dilution (1, 3, 5, 10, 15, 20, 25, 50, 75, up to 100 times)
Sample quality analysis
Lipemia, hemolysis and icterus indices Clot detection and probe crash protection
Calibration
Calibration curve stability up to 90 days (assay dependent) Calibrator value assignment by 2D barcode Calibration curves and parameters displayed on screen
Quality contro
Shewhart day-to-day management (Levey-Jennings method) Multi-rule control (Westgard method)
Reflex testing
User-defined
Calculated result
Pre-defined for the commonly used calculations User-defined
Dimensions and weight
Analyzer with monitor: Weight: Max 992 pounds (450 kg) Length: 6.9 ft (2100 mm) Height: 5.3 ft (1602 mm) Depth: 2.53 ft (770 mm) Clearance Requirements: Clearance around the analyzer for ventilation Rear: Minimum of 20 in (500 mm) Clearance around the analyzer for service Rear: Minimum of 20 in (500mm) Left: 20 in (500 mm) Right: Minimum of 25 in (500 mm) Top: Minimum of 0 in (0 mm) Front: Minimum of 24.7 in (635 mm)
Drain requirements
Drain Location Maximum distance 33 ft (10 m) from the system Maximum height 5 ft (1.5 m) from the floor Drain Volume Concentrated waste: 5.5 L hour (normal), 7.5 L hour HbA1c Diluted waste: 12L/hour
Water supply requirements
Maximum water consumption: 20 L hour Water type: Deionized CAP type II or better, bacteria free Continuous flow supply Resistivity: > 0.5 Mcm filtered with a 0.5 m filter
Power and environmental requirements
Power Supply: 200V, 208V, 220V, 230V, 240V, 60 Hz Computer CPU Intel Core i7-6700 processor Memory: 32GB DDR4 Storage: 512GB SSD Operating system: Windows 10 External communication types: RS232 serial interface Ethernet: LAN using TCP/IP Monitor Touchscreen display: 21.5 in diagonal TFT LCD with projected capacitive touch Interface Pixels: 1920 x 1080 RGB
Operating environment
Ambient temperature: 64F to 90F (18C to 32C) Humidity: 20% to 80% RH (without condensation) Altitude: Maximum 6,561 ft (2,000 m) above sea level Generated Noise Level: <60 dB
Communication modes
Unidirectional, bi-directional, bi-directional with true host query LAN connection to LIS per ASTM protocol
Disclaimer:
"The sale of this item may be subject to regulation by the U.S. Food andDrug Administration and state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject toFDA regulation, I will verify your status as an authorized purchaser of thisitem before shipping of the item."