Item Description

Seller assumes all responsibility for this listing..

Listing: #3056500

  • Condition: Used - Excellent
  • Brand: AGILENT
  • Type: Lab - General
  • Model: 355 SCD
We Have A Agilent Technologies 355 SCD Sulfur Chemiluminescence Detector

The 355 Sulfur Chemiluminescence Detector (355 SCD) is the world’s

most sensitive and selective chromatographic detector for sulfur containing compounds. The 355 SCD is based on patented technology, and it provides a linear and equimolar response to sulfur compounds without interference from most sample matrices. The exceptional performance of the 355 SCD has resulted in its widespread use and acceptance for the analysis of sulfur compounds in a wide range of applications. The new Dual Plasma Burner and Controller significantly enhance the performance of the 355 SCD, increase ease of use, and reduce maintenance.



Specifications



Sensitivity* Typical < 0.5 pg S/second (signal to noise 3.3:1)

Typical Selectivity g S/g C > 2 x 107

Linearity >104

Precision and Stability† <2% RSD 2 hours

<5% RSD 72 hours

Ozone flow through the Post Ozone Restrictor: 20-30 mL/min at 3-6 psig

Typical reaction cell pressure 4 - 8 Torr RV5 Oil Sealed Pump

6 - 12 Torr Dry Piston Pump



Typical Burner Pressure 250-400 Torr operating

Typical Burner Temperature 800 °C

Typical Air Flow Rate 65 SCCM recommended

3-10 SCCM recommended with FID adapter

Typical Hydrogen Flow Rate 40 SCCM recommended

Signal Output Ranges 0-1V, 0-10V



Typical time to reach 800 °C

from room temperature: 10 min typical(120 VAC, 60 Hz)







Typical safety shroud

outside temperature: <65 °C at 800 °C Burner temperature typical

Recorder output 0-1 V or 0-10 V



* Burner temperature 800 °C, 80 SCCM air, and 60 SCCM hyrdrogen, test compound dimethyl sulfide in toluene.



† Based on thiopene in benzene at 1 ppm mass sulfur, 1 µL injection split 1:10, 30 m, 0.32 mm ID, 1 µm thick CP

wax (n=10 for 2.5 hours; n=42 for 72 hours).



Subject to change without notice.



Power Requirements:

355 SCD Detector: 115 VAC, 50/60 Hz, 1400 W

100 VAC, 50/60 Hz, 1400 W

220-240 VAC, 50/60 Hz, 650W



Dimensions and Weight:



Detector Height: 16.0 in (40.6 cm)

Width: 9.2 in (23.4 cm)

Depth: 21.8 in (55.3 cm)

355 SCD Weight: 34.0 lbs (15.0 kg)

255 NCD Weight: 37.5 lbs (17.0 kg)



This Item will be shipped out via Flat Rate Freight on a 48x40 Pallet







- Call or email with your questions , Hablamos Español

- Ship from: Southern California. Global Shipping

- Details of item must be read carefully before buying and /or requesting return



Disclaimer:

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
International Diagnostic Equipment
profile image
Shop with confidence
Citi Capital Groupspacer
Moveitem Shippingspacer
Send the Seller a message: