Service For GE MAC800 MAC800 ECG unit

GE Mac800 ECG EKG Machine Description All medical equipment, new and used, is thoroughly inspected by our engineers to ensure complete functionality. Service contracts for each device are also... view more

June 03  

Service For GE RM6C Ultrasound Transducer

Replace crystal for GE 3D/4D ultrasound probe RM6C Service: Repair motor control problem, replace dome/crystal,replace cable,replace plastic cover and connector 3-5 working days to repair 60... view more

June 03  

Service For GE RM7C Ultrasound Transducer

Replace crystal for GE 3D/4D ultrasound probe RM7C Service: Repair motor control problem, replace dome/crystal,replace cable,replace plastic cover and connector 3-5 working days to repair 60... view more

June 03  
stats
DOTmed text ad

BK and other Urological Systems available. BK Probe repair available!!!

Looking for the leader in urology? BK Medical is and we are the 3rd party experts. We sell BK and many other brands. Call today to discuss your urology equipment needs and save $1,000’s! Call Today: 1-888-838-7488 Email: sales@sentinelimaging.net

DOTmed Certified stats

Service For GE Voluson E10 EM6C

GE 3D/4D convex ultrasound probe EM6C showing error Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover and connector. test video/pics will be... view more

June 03  

Service For GE HEALTHCARE VolusonE6 VolusonE8 RIC5-9-D

GE 3D/4D endocavity ultrasound probe RIC5-9-D replace crystal and replace dome Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover and connector.... view more

June 03  

Service For GE HEALTHCARE VolusonS6 VolusonS8 VolusonS10 RIC5-9W-RS

GE 3D/4D endocavity ultrasound probe RIC5-9W-RS replace dome and repair motor control problem Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover... view more

June 03  

Service For GE HEALTHCARE Repair flat panel DBM128 of GE Voluson S8. Repair flat panel DBM128 of GE Voluson S8.

Faulty Phenomenon Malfunction: during scanning with the use of the US transducer, an artifact in the form of uniform darkening of the entire visualization area is detected. Troubleshooting and... view more

June 03  
stats
DOTmed text ad

CC Medical : Ultrasound systems You Can Trust

CC Medical provides reliable ultrasound systems, probes, system parts, & technical support serving hospitals and healthcare providers domestically & internationally. Wholesale pricing available. 833-309-4229. Se Habla Espanol sales@ccmedicalhs.com

stats

Service For GE HEALTHCARE Repair GE Voluson E10. Repair GE Voluson E10.

Faulty Phenomenon Malfunction: when loading PO, a window appears with the message: Initialization and configuration of hardware failed. Starting simulation. Please restart system. After this... view more

June 03  

Service For GE HEALTHCARE Repairing ultrasound GE Voluson E8 BT13. Repairing ultrasound GE Voluson E8 BT13.

Faulty Phenomenon Malfunction: Upon loading the device, the error "Mixed RSR configuration found" was fixed, due to which the system did not start. Troubleshooting and Solutions Malfunction: Upon... view more

June 03  

Service For GE HEALTHCARE Repair GE Voluson E6 BT19. Repair GE Voluson E6 BT19.

Faulty Phenomenon Description of the problem: during the examination, flickering and interference appear on all sensors. The problem was progressive in nature, that is, with each time the... view more

June 03  

Service For GE HEALTHCARE Repair GE Voluson E10 BT21. Repair GE Voluson E10 BT21.

Faulty Phenomenon Description of the problem: during the examination, all sensors display flickering and interference. The problem was progressive in nature, meaning that with each examination, the... view more

June 03  
stats
DOTmed text ad

Auction Alert - Live Now: Therapeutic Technologies Surplus Auctions June 15th

Therapeutic Technologies closeout auctions take place on DOTmed.com. Bid today on 538 lots of medical equipment. Inspections may be done by appointment. Hours are Monday through Friday 9am-4pm Contact chrisnuytens1@gmail.com to schedule.

stats

Service For GE HEALTHCARE Repair GE Voluson S8 BT16. Repair GE Voluson S8 BT16.

Faulty Phenomenon Description of the problem: when connecting both sensors of the RAB6-RS, an error appears in the Motor Control Unit. Troubleshooting and Solutions Description of the problem:... view more

June 03  

Service For GE HEALTHCARE Repairing the ultrasound device GE ML6-15-D. Repairing the ultrasound device GE ML6-15-D.

Faulty Phenomenon Replacement of the acoustic lens (photo before replacement, inside the post - after... view more

June 03  

Service For GE HEALTHCARE Repairing the ultrasound device GE RM6C. Repairing the ultrasound device GE RM6C.

Faulty Phenomenon Restoration of the sealing of the piston (problem: leakage of oil was detected under the piston). Troubleshooting and Solutions Restoration of the bellows seal (problem: an oil... view more

June 03  

Service For GE HEALTHCARE Repairing GE Voluson E10 equipment. Repairing GE Voluson E10 equipment.

Faulty Phenomenon Malfunction: During the examination, artifacts appear in the form of bright spots, morgania, etc. With each examination, the artifacts increase. Solution: The malfunction was... view more

June 03