Therapeutic Technologies closeout auctions take place on DOTmed.com. Bid today on 538 lots of medical equipment. Inspections may be done by appointment. Hours are Monday through Friday 9am-4pm Contact chrisnuytens1@gmail.com to schedule.
Looking for the leader in urology? BK Medical is and we are the 3rd party experts. We sell BK and many other brands. Call today to discuss your urology equipment needs and save $1,000’s! Call Today: 1-888-838-7488 Email: sales@sentinelimaging.net
Fix/Exchange GE Board Repair time: 2-4 days Our experienced maintenance team can help with circuit board repairs of MRI, CT, Gamma Camera, Ultrasound... view more
We provide end of life (EOL) service for all GE MAC LABS. We also buy EOL units. We have a full stock of GE MAC LABS & PARTS Please email or call for pricing.... view more
GE Mac800 ECG EKG Machine Description All medical equipment, new and used, is thoroughly inspected by our engineers to ensure complete functionality. Service contracts for each device are also... view more
If you have a broken Sonosite, Mindray, GE, Philips, Hitachi, or Aloka system or probe contact us today. Free ultrasound & probe EVALS with 1 Year Warranty on all repairs. We repair all orders in 1-5 days. Call 844-644-5440 Email: Sales@Lenard.Healthcare
Replace crystal for GE 3D/4D ultrasound probe RM6C Service: Repair motor control problem, replace dome/crystal,replace cable,replace plastic cover and connector 3-5 working days to repair 60... view more
Replace crystal for GE 3D/4D ultrasound probe RM7C Service: Repair motor control problem, replace dome/crystal,replace cable,replace plastic cover and connector 3-5 working days to repair 60... view more
GE 3D/4D convex ultrasound probe EM6C showing error Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover and connector. test video/pics will be... view more
GE 3D/4D endocavity ultrasound probe RIC5-9-D replace crystal and replace dome Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover and connector.... view more
We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.
GE 3D/4D endocavity ultrasound probe RIC5-9W-RS replace dome and repair motor control problem Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover... view more
Faulty Phenomenon Malfunction: during scanning with the use of the US transducer, an artifact in the form of uniform darkening of the entire visualization area is detected. Troubleshooting and... view more
Faulty Phenomenon Malfunction: when loading PO, a window appears with the message: Initialization and configuration of hardware failed. Starting simulation. Please restart system. After this... view more
Faulty Phenomenon Malfunction: Upon loading the device, the error "Mixed RSR configuration found" was fixed, due to which the system did not start. Troubleshooting and Solutions Malfunction: Upon... view more
CC Medical provides reliable ultrasound systems, probes, system parts, & technical support serving hospitals and healthcare providers domestically & internationally. Wholesale pricing available. 833-309-4229. Se Habla Espanol sales@ccmedicalhs.com
Faulty Phenomenon Description of the problem: during the examination, flickering and interference appear on all sensors. The problem was progressive in nature, that is, with each time the... view more
Faulty Phenomenon Description of the problem: during the examination, all sensors display flickering and interference. The problem was progressive in nature, meaning that with each examination, the... view more
Faulty Phenomenon Description of the problem: when connecting both sensors of the RAB6-RS, an error appears in the Motor Control Unit. Troubleshooting and Solutions Description of the problem:... view more
Faulty Phenomenon Replacement of the acoustic lens (photo before replacement, inside the post - after... view more