Americomp Spectra 30HF Error
October 11, 2019 10:54

Americomp Spectra 30HF . Failure: E11 Communication error. Hello, dear colleagues. I am looking for help to solve a failure on a x-ray equipment from the Americomp brand. At power on, buzzer in operator's console always soun...Click here to read more

Acuson Sequoia c512 Service Manual and SW
September 26, 2019 06:06

Hello Randy, Can you send me the service manual for the acuson sequoia 512? please?? ...Click here to read more

AQUILION 64 ARTIFACT LIKE DOT
September 16, 2019 09:41

We did it. Just xray tube left! ...Click here to read more

AQUILION 64 ARTIFACT LIKE DOT
September 16, 2019 09:41

Everthing is Ok. We will change tube. ...Click here to read more

AQUILION 64 ARTIFACT LIKE DOT
September 16, 2019 09:40

Thank you!...Click here to read more

AQUILION 64 ARTIFACT LIKE DOT
September 16, 2019 09:40

Yes, we already think that is the xray tube. We did all the measures needed and it is the only thing left. ...Click here to read more

AQUILION 64 ARTIFACT LIKE DOT
September 06, 2019 09:22

Hello Uldis, Yes, and it looks everything ok. It is just in skull studies. And it doesn't show in every skull study as well. ...Click here to read more

AQUILION 64 ARTIFACT LIKE DOT
September 06, 2019 09:17

Hello, There is no contrast on the detector and, collimator is ok as well. About Recon it is also Ok. ...Click here to read more

AQUILION 64 ARTIFACT LIKE DOT
September 01, 2019 12:08

We installed a Aquilion 64 about a year ago, it was a very estable system but in march we started to have artifact in images, not perceptible but yes. We have troubles with a board, optcont2 (it has MUDAT transmission data sys...Click here to read more

siemens mammomat 3000 nova service manual
March 05, 2019 09:48

Hello Kaustubh, Can you please send me the Installation, Maintenance and Service ? My email is selmazamora@imesamex.com...Click here to read more

TOSHIBA AQUILION 4 error in XC 0xb2640000 DEV 0X0001002
June 12, 2018 03:23

Thank you Wang. I already sent you an email...Click here to read more

TOSHIBA AQUILION 4 error in XC 0xb2640000 DEV 0X0001002
June 12, 2018 03:23

Yes perfect... Let you know when we are in site ...Click here to read more

TOSHIBA AQUILION 4 error in XC 0xb2640000 DEV 0X0001002
June 10, 2018 09:16

Yes. ERROR INF dump SSADI STATUS ss_state[0x0010] valid_bit[0x0 GTS STATUS] mode [OR] exe [AD] error [0x000 Interlock slide [00] height [00] free&light[00] out2censor censMUDAT status [0x0000] GTS detail status detail error...Click here to read more

TOSHIBA AQUILION 4 error in XC 0xb2640000 DEV 0X0001002
June 10, 2018 09:16

Hello Tolga, Yes. We did the calibration. ERROR INF dump SSADI STATUS ss_state[0x0010] valid_bit[0x0 GTS STATUS] mode [OR] exe [AD] error [0x000 Interlock slide [00] height [00] free&light[00] out2censor censMUDAT stat...Click here to read more

STRUCTURE SITE STOPS
May 17, 2018 02:48

Hello Guys, We are working on a Axiom Iconos R200. We are having problems to go in the menu > Structure Site, when we are in there, the charging bar starts to run but it comes a moment when it stops in (9%) and says that th...Click here to read more