Over 100 Massachusetts Auctions End Today - Bid Now
Over 1750 Total Lots Up For Auction at Five Locations - NJ Cleansweep 05/02, TX 05/03, TX 05/06, NJ 05/08, WA 05/09

spacer
This Item is no longer available.

Click here to see the 20 Equipment Listings matching 'ENVITEC Compatible O2 Cell for Covidien Puritan Bennett - 4-072214-00 Respiratory - Oxygen Sensor' on DOTmed

Post a free Request For Proposal for a ENVITEC Compatible O2 Cell for Covidien Puritan Bennett - 4-072214-00 Respiratory - Oxygen Sensor and get quotes from our Gold Service Dealers
Listing 3239106 Listing 3239106 Listing 3239106
Listing 3239106 Listing 3239106 Listing 3239106

For Sale ENVITEC Compatible O2 Cell for Covidien Puritan Bennett - 4-072214-00 Oxygen Sensor

  • Asking Price :$119.95 USD [convert]
  • Condition : New
  • Weight : 1.00 Lbs
  • Qty. Available : 1
  • Date : March 25, 2024
  • Listing # : 3239106
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #3239106

  • Condition: New
  • Brand: ENVITEC
  • Type: Oxygen Sensor
  • Model: Compatible O2 Cell for Covidien Puritan Bennett - 4-072214-00
  • MPN: OOM202
THIS PRODUCT IS NO LONGER AVAILABLE.

100% New Genuine OOM202 Envitec Oxygen Sensor

MPN: OOM202

Beware of Knockoffs and Imitations from China. Our stock is guaranteed AUTHENTIC and ORIGINAL!

Ships from USA warehouse.

Features
• Compliant with European MDD (CE certification)
• Meets ISO 80601-2-55
• Designed and manufactured according to EN ISO 13485
• Accurate and reliable fast response
• Resistant to N2O
• Excellent signal stability
• High product quality
• Short delivery times
• Technical support
• Made in Germany
• FDA approved

Technical Specifications:
Measurement range 0 % ... 100 % oxygen (at atmospheric pressure)
Nominal sensor lifetime ≥ 1 000 000 % volume oxygen hours
Output in ambient air 13 mV ... 16 mV
Electrical interface 3 pin (Molex® 22-11-1031)
Accuracy meets ISO 80601-2-55 requirements
Repeatability < 1 % volume O2 at constant temperature and pressure
Linearity error < 3 % relative
Response time < 12 s to 90 % of final value
Zero offset voltage < 200 µV in 100 % nitrogen, applied for 5 min
Cross interference meets ISO 80601-2-55 requirements
Influence of humidity -0.03 % rel. per % RH at 25 °C
Pressure range 0.6 bar ... 2 bar (ppO2 0 ... 1250 mbar O2)
Influence of pressure proportional to change in oxygen partial pressure
Influence of mechanical shock < 1 % relative after a fall from 1 m
Operating temperature 0 °C ... +50 °C
Temperature compensation built-in NTC compensation
Effect of temperature compensation (steady state)
between +25 °C and +40 °C: 3 % relative error
between 0 °C and +50 °C: 8 % relative error
Operating humidity 0 % ... 99 % RH non-condensing
Long term output drift < 1 % volume oxygen per month
typically < -15 % relative over lifetime
Storage temperature -20 °C ... +50 °C
Recommended storage +5 °C … +15 °C
Recommended load ≥ 10 kOhms
Warm-up time < 30 minutes, after replacement of sensor
Weight approximately 28 grams

Return Policy