Faulty Phenomenon Repair flat RSR14, RSR19 (PN: KTZ196357, KTZ196310) and RST15, RST20 (PN: KTZ196358, KTZ280122) malfunction: when turning on, the image begins to intensively display white noise... view more
Faulty Phenomenon Repair the Main Power Supply (PN: 5205052-7) power supply block. This power supply unit is also suitable for Vivid E9. Malfunction: does not turn on the device, no 48 V on the... view more
Faulty Phenomenon Repair of electronic volume transducer GE eM6C malfunction: error code (ASIC thermal info error 0x10A6), began to issue an error due to overheating, the cause of which is the... view more
Faulty Phenomenon Repair RFM423 (PN: KTZ304074) of the GE Voluson E10 (versions BT17, BT18, BT19, BT20, BT21) device. Malfunction: when turning on the probe, the image begins to display intense... view more
Faulty Phenomenon Repair flat panel DBM128G ASSY (PN:5573638-2) from GE Voluson S10 BT18. Malfunction: when turning on the device, the image begins to intensively display white noise across the... view more
Faulty Phenomenon LOGIQ P5 has no response at startup. Troubleshooting and Solutions GE LOGIQ P5 Repair: Solved No Power/No Startup Issue 🔋 The Problem The LOGIQ P5 system showed no... view more
Faulty Phenomenon GE LOGIQ P9 Ultrasound Repair: Fixed Image Dark Line Issue Troubleshooting and Solutions GE LOGIQ P9 Ultrasound Repair: Fixed Image Dark Line Issue ⚡ Problem Reported A... view more
Faulty Phenomenon GE LOGIQ P6 machine have interference in color Doppler mode Troubleshooting and Solutions GE LOGIQ P6 Ultrasound Repair Case: Solving Color Doppler Interference ⚡ What Was... view more
Faulty Phenomenon GE VIVID I Ultrasound System Repair Case: Fixing "Probe Not Recognized" Error Troubleshooting and Solutions GE VIVID I Ultrasound System Repair Case: Fixing "Probe Not... view more
Faulty Phenomenon Repair power supply module (APS Assy PN: 5166108) from GE Logiq P5/A5 device malfunction: device fails to start, no ultrasound imaging, no high voltage, no indicator light. ... view more
Faulty Phenomenon Repair of the motherboard (MotherBoard) of the GE Voluson E8 BT13 device (replacement of RAM). During the repair process, technical maintenance was carried out. Malfunction: the... view more
Faulty Phenomenon Repair flat panel DBM128G ASSY (PN:5573638-2) from GE Voluson S8 BT18. Malfunction: when turning on the device, the image begins to intensely display white noise across the entire... view more
Faulty Phenomenon Repair RFI20, RFI21 (PN: KTZ280098, KTZ302197) malfunction: In the CDS (color Doppler) mode, artifacts appear, and all the image in the region of interest is colored in various... view more
Faulty Phenomenon Repair flat BF192 Assy(PN: 5357234-2, 5357234-20, 6357234) (compatible with versions R1, R2, R3, R4) malfunction: when turning on the display, the image starts to intensively... view more
Faulty Phenomenon The system occasionally showed subtle "snowflake" interference on images. Minor flickering also appeared when using the keyboard, though patient exams remained possible. ... view more