Configuration: (3) Complete laser devices, one control station
Lasers:
1 - Class 3a (635nm) - (2) 5 milliWatt Diodes
1 - Class 3b (635nm) - (2) 7.5 milliWatt Diodes

Ad Statistics
Times Displayed: 113104
Times Visited: 6738 MIT labs, experts in Multi-Vendor component level repair of: MRI Coils, RF amplifiers, Gradient Amplifiers Contrast Media Injectors. System repairs, sub-assembly repairs, component level repairs, refurbish/calibrate. info@mitlabsusa.com/+1 (305) 470-8013
1 - Class 3a (405nm) - (2) 5 milliWatt
Wavelength: 635 nm, 405nm
Frequency: Variable from 1hz - 50,000hz
Capable of up to twenty (20) presets
Weight: Unit with Probes 7.45 lbs. Probes .75 lbs each
Material: Fire rate, high impact PC/ABS
Battery: Rechareable Lithiom-Ion
Power Source: 110/220VAC
Process and Machine Patented US Patent No. (6,605,079B2; 6,013,096; 6,746,473)
Certified in accordance to:
ISO 9000 Quality Standards
ISO 13485 Medical Device Standards
FDA Good Manufacturing Practices
Approved Testing:
IEC 60601-1-2
MDD 93/42/EEC
EN4600
IEC60825-1 Laser Safety
No. 15448: CYNOSURE Smart Lipo Laser - Yag
You are bidding on a Cynosure 10 WATT Laser Guided Liposuction Unit.
This unit was manufactured brand new in April 2007 and has had very minimal use.
Specs : Nd: YAG
Wavelength: 1064nm
Maximum Rep Rate: 40Hz
Electrical Requirements: 110 VAC/20A
Dims: 28"H x 9" W x 25"D @ 84 lbs.
Included with the Smartlipo:
- 1 key to operate the machine
- 1 Footswitch
- power cord
- 1 blue protective cover
- CYNOSURE Smartlipo Fiber Kit with Accessories
Includes:
-3 handpieces,
-5 pcs - NEW 600 micron optic fibers
-cleaver, stripper, tape measure, fiber cleaving guide, screw driver.
-Cynosure marketing kit
No. 15777: GE Advantx Rad/Tomo Room
You are bidding on a GE Advantx Rad/Tomo Room.
This room was installed in 1993.
-LFX generator manufactured in 1993.
-Tube manufacture BVM S.r.I.,
-Model # of tube: Ultranet-SA, model # ZAOULOSA-45296001, May 1997
-New console replaced in 2008
-B0577D RTE Horizontal Table that elevates
-Maximum Mas 1250 mAs
-Phototiming
-Wall bucky
This room is in good working condition. Currently the room is barely used. The facility primarily uses their digital room and use this room as the
back-up if the digital one goes down. It has been at least four months since clinical use
This unit is under GE full service contract-please inquire in for service records.
The room is being sold due to facility updating their technology.
No. 13234: DADE BEHRING Stratus CS Chemistry Analyzer
You are bidding on a DADE BEHRING Stratus CS Chemistry Analyzer.
SN: 98052006