Over 100 California Auctions End Today - Bid Now
Over 350 Total Lots Up For Auction at Two Locations - CO 05/12, PA 05/15

Strong uptake of RayStation Monte Carlo Dose Engine among proton therapy centers

Press releases may be edited for formatting or style | May 22, 2018 Rad Oncology Proton Therapy
STOCKHOLM, May 21, 2018 /PRNewswire/ -- 13 out of 18 RayStation proton sites in clinical operation are now using the proton Monte Carlo (MC) dose engine, and this just a year after it was released. That according to a survey. "The implementation of the RayStation Monte Carlo dose engine has expanded our capability to serve more and a wider range of patients", says Chang Chang, Director of Physics, Texas Center for Proton Therapy.

One year after RaySearch's first release of the proton MC dose engine in RayStation 6, a survey was sent out to the 18 RayStation proton sites that are in clinical operation with pencil beam scanning. The survey focused on the clinical implementation and use of the new MC dose engine. The answers showed that no less than 13 of the 18 clinics have implemented the MC dose engine in their clinical work flows, with remaining clinics currently in commissioning. Several clinics report that they use the MC dose engine for all patients, while others use it for selected cases where high accuracy is important, such as lung, brain, breast or head and neck.

Peer reviewed research papers are being published showing that Monte Carlo is now considered key for certain cancer types, which has prompted rapid implementation and acceptance. One prime example is "Pencil Beam Algorithms Are Unsuitable for Proton Dose Calculations in Lung"[1] .
stats Advertisement
DOTmed text ad

Training and education based on your needs

Stay up to date with the latest training to fix, troubleshoot, and maintain your critical care devices. GE HealthCare offers multiple training formats to empower teams and expand knowledge, saving you time and money

stats
Significantly, all clinics that have adopted MC for final dose computation, state that they also use it to drive the optimization. No significant deviations in the clinics validation studies have been reported. Also, all clinics mention very good results in the patient specific QA, especially for fields that employ a range shifter as compared to the results with the analytical dose engine.

Chang Chang, Director of Physics, Texas Center for Proton Therapy says: "The implementation of the RayStation Monte Carlo dose engine has expanded our capability to serve more and a wider range of patients. For example, it enabled us to use larger range shifter to patient air gaps, which streamlined our process in the treatment rooms. In addition, the higher accuracy of the Monte Carlo dose engine allowed us to treat sites like lung, complicated head and neck, and breast with more confidence."

Xavier Vermeren, Chief physicist, West German Proton Therapy Centre Essen says: "Now, when we find a rare deviation in our patient specific QA, we always double check our QA setup and data first. We simply expect the RayStation Monte Carlo dose to be correct, and we have yet to see a field that fails the QA."

You Must Be Logged In To Post A Comment