DOTmed Home MRI Oncology Ultrasound Molecular Imaging X-Ray Cardiology Health IT Business Affairs
News Home Parts & Service Operating Room CT Women's Health Proton Therapy Endoscopy HTMs Mobile Imaging
SEARCH
Current Location:
>
> This Story


Log in or Register to rate this News Story
Forward Printable StoryPrint Comment

 

 

Women's Health Homepage

Photoacoustic CT tech developed for early stage breast cancer detection Safer, more efficient, and more affordable than mammography, MR and ultrasound: developer

Study finds combined 2D and 3D mammo screening detects 90 percent more cancers Downsides include overdiagnoses and longer read times

Q&A with Dr. Bruce F. Schroeder, owner of Carolina Breast Imaging Specialists, PLC Why his facility chose automated breast ultrasound and what it has meant for dense breast patients

Why are breast cancer survivors foregoing recommended screening? Study finds poor adherence to annual mammogram guidelines

Automated breast-density evaluation equal to radiologist assessments Researchers from UCSF and Mayo Clinic conduct comparative study

AI-powered software for breast density assessment gets FDA nod Densitas aims to bring standardization to density assessment

How to lower breast MR wait times from 101 days to five University of Michigan shares lessons that other facilities can learn from

Breast cancer risk assessment should start at age 30: ACR, SBI New guidelines put focus on high-risk populations

Wisconsin passes breast density reporting mammography bill 35th state to require patients to be notified

Women who undergo partial or reduced breast radiotherapy report fewer side effects A viable option for low-risk breast cancer: study

Barco Coronis Uniti

Higher display luminance may correct effects of lower radiation dose in mammography

by Lisa Chamoff , Contributing Reporter
Increasing display luminance when reading a mammogram may allow for decreased radiation dose during an exam without sacrificing image quality and diagnostic accuracy, according to a study presented at the recent SIIM annual meeting.

Dr. Elizabeth Krupinski, an experimental psychologist who serves as vice chair for research in the Department of Radiology and Imaging Sciences at Emory University, has been studying various imaging display technologies for more than 25 years. She said Barco – which manufactures a 12-megapixel monitor with a proprietary feature called SpotView that focuses light on areas being viewed more closely, mimicking the bright light used in film mammography to enhance the visibility – approached her about studying the technology’s effect on dose.

Story Continues Below Advertisement

Breast Health Solutions

Innovative AI software solutions built on deep learning for breast tomosynthesis, breast density and 2D mammography. Learn more>



“Since I’m one of the few people in the world that does this type of analysis, I thought this would be interesting,” Krupinski told HCB News.

For the study, Krupinski took two phantom images using a full-field digital mammography system. Each exam used 26-kilovolts, but one had a lower radiation dose – 45 milliamperage-seconds (mAs) versus 50 mAs – resulting in entrance surface doses of 7.093 milligray (mGy) and 7.880 mGy. The images were processed so that the average gray level of the background was independent of the dose level, while maintaining signal to noise ratio.

Eight radiologists viewed the images on Barco’s Coronis Uniti monitors using a luminance of 420 candela per square metre (cd/m2), 1,000 cd/m2 and the monitor’s SpotView feature, which covered the entire image generated by the phantom. When reading a clinical mammogram, radiologists would use the feature to highlight specific areas of the image.

Krupinski calculated the percentage the radiologists were correct in detecting abnormalities and the average time they spent per image.

While diagnostic accuracy was higher overall for the high-dose images, SpotView followed by the 1,000 cd/m2 luminance increased diagnostic accuracy significantly over the 420 cd/m2 luminance for the lower-dose images. The time spent per image decreased with the increase in luminance.

Specifically, increasing the display luminance from 400 cd/m2 to 1,000 cd/m2 increased reading accuracy by approximately 3 percent and decreased reading time by about 6 percent. The use of SpotView increased reading accuracy by about 6.2 percent and decreased reading time about 16 percent.

“Perhaps one can go a bit further and help correct the effects of the lower doses with this luminance tool,” Krupinski said.

Krupinski, who gave an oral presentation on the study at SIIM and also submitted it to the Journal of Digital Imaging, said the next step is to look at the effect of luminance and the SpotView technology on clinical images.

“Barco Healthcare is continually looking for ways to streamline radiology workflow and support the best patient care,” Lynda Domogalla, vice president of product marketing at Barco Healthcare told HCB News. “We are proud that with SpotView and Coronis Uniti we can help healthcare professionals to achieve both, with proven enhancements to workflow and the possibility to reduce mammographic radiation dose without impacting diagnostic accuracy.”

Women's Health Homepage


You Must Be Logged In To Post A Comment

Advertise
Increase Your
Brand Awareness
Auctions + Private Sales
Get The
Best Price
Buy Equipment/Parts
Find The
Lowest Price
Daily News
Read The
Latest News
Directory
Browse All
DOTmed Users
Ethics on DOTmed
View Our
Ethics Program
Gold Parts Vendor Program
Receive PH
Requests
Gold Service Dealer Program
Receive RFP/PS
Requests
Healthcare Providers
See all
HCP Tools
Jobs/Training
Find/Fill
A Job
Parts Hunter +EasyPay
Get Parts
Quotes
Recently Certified
View Recently
Certified Users
Recently Rated
View Recently
Certified Users
Rental Central
Rent Equipment
For Less
Sell Equipment/Parts
Get The
Most Money
Service Technicians Forum
Find Help
And Advice
Simple RFP
Get Equipment
Quotes
Virtual Trade Show
Find Service
For Equipment
Access and use of this site is subject to the terms and conditions of our LEGAL NOTICE & PRIVACY NOTICE
Property of and Proprietary to DOTmed.com, Inc. Copyright ©2001-2018 DOTmed.com, Inc.
ALL RIGHTS RESERVED