ALCON 20000 LEGACY PHACOEMULSIFICATION UNIT
DOM: 02/1997
SOFTWARE REVISION: 3.0
REV:N
POWER SPECS:

Ad Statistics
Times Displayed: 22687
Times Visited: 478 Stay up to date with the latest training to fix, troubleshoot, and maintain your critical care devices. GE HealthCare offers multiple training formats to empower teams and expand knowledge, saving you time and money
90-125 V
50-60 Hz
10 A
The new series Alcon 20000 Legacy is designed for use in anterior segment procedures that require simultaneous lens fragmentation, irrigation, and aspiration; as well as associated procedures such as vitrectomy and coagulation.It is developed with a dual purpose: to make it simple to operate, and to allow the surgeon tremendous control and flexibility.
No. 4158 : KODAK DryView 8100 Dry Camera
You are bidding on a Kodak DryView 8100.
Model#: 8100
Serial #: K-4163-0325
No. 4178 : LORAD MIII Mammo Unit
LORAD MIII
DOM: 09/1992
System Power Specifications:
-220 Volts
-50/60 Hz
-19.8 Amps
-2.0 Amps-LT
Tube (DOM: 08/2002)
Includes:
-Lead Glass
-15" H.P. Flat Screen Monitor
-Auto Film I.D.
-Dual Buckys
-(1)Cassette Holder
-(6)Compression Paddles
-(5)Appertures
No. 4179 : PHILIPS PMX-2000 Portable X-Ray
System has been engineer tested and is in excellent working condition.
New batteries installed 02/09/2007.
DOM : May 1998.
X-ray system 9804-086-0009
High voltage generator 4512-590-10161
X-ray control 9-400-0013
Collimax p-180hs-g collimator.
The Philips PMX-2000 is a battery powered, self-propeled x-ray unit; drive system has a pair of independent battery-powered motors, 2 10-inch drive wheels, 2 8-INCH front casters, & a pressure sensitive drive handle with a built-in brake release bar. Contains a rotating anode x-ray tube w/ 0.7 mm focal spot and a retractable AC charge cord. X-Ray Control Specifications Technique Factor Selection Front panel pushbuttons increment/decrement kVp and mAs on LED readouts Exposure Control Pendant mounted two position (Boost Cycle and X ray) switch mounted on 8 foot cord, control panel indicators light to show status Exposure Timing Microprocessor controlled Selectable kV Ranges 40 - 125 kVp total in 2 kVp steps from 40 -80 kVp, and 5 kVp steps from 80-125 kVp Selectable mAs Ranges 0 1 - 325 mAs total 1 - 325 mAs maximum from 40 to 61 kVp .4 to 325 mAs maximum from 62-90 kVp .4 to 250 mAs maximum from 95- 105 kVp 4 to 200 mAs maximum from 110- 125 kVp Selectable mAs Increments' 0.1 - 325 mAs : 25% increments; 20% decrements Output Power 12 kilowatts maximum Maximum Current 150 mA for 80 kVp