Real-time imaging of lung lesions during surgery helps localize tumors and improve precision

Press releases may be edited for formatting or style | July 29, 2015

In seven of the 50 cases (14%), the tumor could easily be identified by its fluorescence. The tumors ranged in size from 1.1 to 8.0 cm, but size did not influence fluorescence. All of these tumors were within 1.2 cm of the lung surface.

Of the remaining 43 tumors, 39 appeared fluorescent after the overlying tissue was opened and the tumor exposed. The fluorescence was uniform across the tumor's surface, and the demarcation between tumor and normal surrounding tissue was clearly visible. On average, the optical imaging was quick, ranging from five to 15 minutes.

stats
DOTmed text ad

We repair MRI Coils, RF amplifiers, Gradient Amplifiers and Injectors.

MIT labs, experts in Multi-Vendor component level repair of: MRI Coils, RF amplifiers, Gradient Amplifiers Contrast Media Injectors. System repairs, sub-assembly repairs, component level repairs, refurbish/calibrate. info@mitlabsusa.com/+1 (305) 470-8013

stats

The technique proved to be particularly helpful in two cases. In a 50-year old man thought to have a 2.1 cm primary lung adenocarcinoma in the right upper pulmonary lobe, molecular imaging of the excised lobe identified a second pulmonary nodule that was fluorescent, leading to re-staging of the patient. In another patient, who was thought to have no evidence of metastatic disease, molecular imaging showed evidence of cancer elsewhere.

Four tumors (8%) did not exhibit fluorescence, and further analysis showed that these tumors did not express FRα antigens to allow localization of the contrast agent to the tumor. Thus, the FRα imaging agent is not useful for all lung adenocarcinomas.

"This technology is safe," stated Dr. Singhal. "The use of a visible-wavelength fluorophore avoids ionizing radiation and confers no risk to the patient, surgeon, or operating room personnel. In our experience, only one patient had a mild allergic reaction to the contrast agent that was easily managed with diphenhydramine. With miniaturization of imaging devices, this method will be particularly useful in minimally invasive surgery, such as VATS and robotic surgery."

"What Okusanya and colleagues have discovered is that they can make 92% of all adenocarcinomas glow to the naked eye, requiring no special training at all," noted Michael I. Ebright, MD, of the Section of Thoracic Surgery, New York-Presbyterian/Columbia University Medical Center (New York) in an accompanying editorial. "The Achilles' heel of the technique is tumor depth beneath the pleural surface," as fluorescence was not detectable to the operating surgeon in tumors buried within the lung. However, he added that "this study should be viewed as a launching pad rather than be judged solely on practicality in its current form." Dr. Ebright looks forward to modification of the system so that it can be used in minimally invasive surgery.

Lung cancer is the leading cause of cancer deaths, with approximately 221,200 deaths due to lung cancer anticipated in 2015. About 85% of lung cancers are non-small cell lung cancers (NSCLC), and adenocarcinoma of the lung is one of the most common forms of NSCLC, in both smokers and nonsmokers.