Cardiac Imaging Method May Expose Patients to High Radiation Dose

by Barbara Kram, Editor | February 04, 2009
JAMA
CHICAGO - Use of the imaging technique known as cardiac computed tomography (CT) angiography (CCTA) has the potential to expose patients to high doses of radiation, and methods available to reduce radiation dose are not frequently used, according to a study in the February 4 issue of JAMA.

The 64-slice (able to scan 64 images per rotation) CCTA has emerged as a useful diagnostic imaging method for the assessment of coronary artery disease and has been proposed to be useful for evaluating patients in emergency departments with chest pain. "With the constantly increasing number of CCTA-capable scanners worldwide, the volume of CCTA scans performed is likely to show substantial further increase," the authors write. They add that the clinical usefulness of CCTA for the assessment of coronary artery disease has to be weighed against the radiation exposure of CCTA and the small but potential risk of cancer. Many clinicians may still be unfamiliar with the magnitude of radiation exposure that is received during CCTA in daily practice and with the factors that contribute to radiation dose, according to background information in the article.

Jörg Hausleiter, M.D., of the Deutsches Herzzentrum Munchen, Klinik an der Technischen Universitat Munchen, Munich, Germany, and colleagues investigated the magnitude of radiation dose of CCTA in daily practice, factors contributing to radiation dose and the use of currently available strategies to reduce radiation dose. The trial, the Prospective Multicenter Study On Radiation Dose Estimates Of Cardiac CT Angiography In Daily Practice I (PROTECTION I), an international, multicenter study (21 university hospitals and 29 community hospitals) included 1,965 patients undergoing CCTA between February and December 2007. Analysis was used to identify independent predictors associated with radiation dose, which was measured as dose-length product (DLP; equals the average radiation dose over a specific investigated volume multiplied by the scan length), which best mirrors the radiation a patient is exposed to by the entire CT scan, according to the authors.
stats
DOTmed text ad

Your Trusted Source for Sony Medical Displays, Printers & More!

Ampronix, a Top Master Distributor for Sony Medical, provides Sales, Service & Exchanges for Sony Surgical Displays, Printers, & More. Rely on Us for Expert Support Tailored to Your Needs. Email info@ampronix.com or Call 949-273-8000 for Premier Pricing.

stats
The researchers found that the median (midpoint) DLP of the patients in the study was 885 mGy x cm (a measurement of absorbed radiation), which corresponds to an estimated radiation dose of 600 chest x-rays. A high variability in DLP was observed between study sites (range of median DLPs per site, 331-2,146 mGy x cm).

Independent factors associated with radiation dose were patient weight (relative effect on DLP, 5 percent); absence of stable sinus rhythm (type of heart rhythm; 10 percent effect); scan length (a 1-cm increase in the scan length was associated with a 5 percent increase in DLP); the use of electrocardiographically controlled tube current modulation (resulting in a reduction of DLP of 25 percent, applied in 73 percent of patients); 100-kV (kilo volts) tube voltage (46 percent reduction of DLP, applied in 5 percent of patients); sequential scanning (78 percent reduction; applied in 6 percent of patients); experience in cardiac CT (1 percent reduction); number of CCTAs per month; and type of 64-slice CT system (for highest vs. lowest dose system, 97 percent effect).