Auburndale, MA, March 28, 2011 - Wide Beam Reconstruction (WBR), an innovative software program for the reconstruction of nuclear medicine images, reduces the required radiopharmaceutical dose and image acquisition time by 50 percent for diagnostic quality myocardial perfusion SPECT (MPI), compared to conventional techniques, according to a new study published in the March-April 2011 issue of the Journal of Nuclear Cardiology. Researchers found that with either half the dose of Tc-99m sestamibi or half the acquisition time, WBR resulted in image quality superior to processing with today's widely used OSEM (Ordered Subset Expectation Maximization) software. The study was conducted at St. Luke's-Roosevelt Hospital and Columbia University College of Physicians and Surgeons in New York City.
"The escalating radiation levels of today's advanced imaging exams is causing growing concern among the medical community and the public at large," said Gordon DePuey, lead researcher and MD, Director of Nuclear Medicine at St. Luke's-Roosevelt Hospital and Professor of Radiology at Columbia University. "There is significant pressure to minimize radiation dose, particular for MPI nuclear SPECT exams." In addition, the ongoing shortages of radiopharmaceuticals due to nuclear reactor downtime compound the need to minimize dosage.
Developed by UltraSPECT (Haifa, Israel) to address just these concerns, WBR is an innovative reconstruction algorithm incorporating depth-dependent resolution recovery and image noise modeling to deliver a higher quality image with lower count density data.

Ad Statistics
Times Displayed: 22483
Times Visited: 455 Stay up to date with the latest training to fix, troubleshoot, and maintain your critical care devices. GE HealthCare offers multiple training formats to empower teams and expand knowledge, saving you time and money
In the new MPI study, researchers evaluated images from 156 patients undergoing myocardial perfusion SPECT with a standard full-time acquisition protocol processed with routine OSEM methods. The same 156 patients underwent half-time acquisition, and the data were processed with the WBR algorithm. The images were acquired both at rest and following exercise or pharmacologic stress. A second study group of 160 patients received half of the standard radiopharmaceutical dose, with images acquired for the full standard acquisition time. These were processed using WBR only.
All images were rated for quality by two observers unaware of the acquisition and processing methods. For both the lower dose and abbreviated acquisition time images, grading parameters included myocardial count density and uniformity, endocardial and epicardial edge definition, visualization and definition of the right ventricle, and background noise. For the abbreviated acquisition time images only, SPECT perfusion defects also were examined.