Over 450 Total Lots Up For Auction at Three Locations - CO 05/12, PA 05/15, NY 05/20

Aortica Corporation announces successful completion of first two cases using AortaFit system

Press releases may be edited for formatting or style | February 12, 2016
BELLEVUE, Wash.--(BUSINESS WIRE)--Aortica Corporation today announced the successful completion of the first two cases using their AortaFit™ system to support simplified fenestrated endovascular aneurysm repair (FEVAR). Two procedures were performed by Dr. Benjamin Starnes, Chief of Vascular Surgery at the University of Washington (UW), as part of his physician-sponsored IDE study. The AortaFit™ System is an investigational surgical planning tool comprised of Aortica’s Fenestration Alignment Software and a patient-specific 3D-printed fenestration template. In both cases, the presence of branch arteries near the aneurysms and angulated patient anatomy limited the available treatment options. Using only a CT scan, the Aortica software analyzed each patient’s native aorta and determined how each endograft would influence the vessel geometry once implanted. Using this information, the software precisely determined the appropriate locations of fenestrations (or holes in the graft) to align with the branch arteries. A 3D printer then generated patient-specific AortaFit™ templates that Dr. Starnes used in the operating room to guide his modification of each graft. Standard “off-the-shelf” Medtronic and Bolton Medical endografts were used in these first two cases. By accounting for the branch arteries, the grafts provided a more secure fixation and seal while still allowing for blood to continue to flow to vital organs fed by the branch arteries.

“These two cases represent a first step toward making fenestrated EVAR a simple procedure that is available to many more physicians and patients,” stated Dr. Starnes. “The Aortica software made case planning so much easier and the AortaFit™ template shortened the time for graft modification in the OR. Our first case was a 74-year-old male with a 6cm juxtarenal aneurysm. The arteries that supplied his kidneys were only 7mm from the beginning of the aneurysm, meaning there was not adequate space to anchor a standard endograft,” continued Dr. Starnes. “Using the AortaFit™ System, we generated a 3 fenestration template that precisely matched the anatomical requirements of our patient. I was able to very quickly and easily modify a standard Medtronic Endurant II endograft. The alignment of the fenestrations was perfect; the graft was easily placed and we increased the effective seal zone from 7mm to 39.2mm. The entire procedure took 1 hour and 53 minutes.”

“The second case was also a 74-year-old male who underwent open surgical repair 6 years earlier,” Dr. Starnes continued. “Unfortunately his disease continued to progress. The aneurysm had grown to 6cm, and was now located just 2mm from arteries branching out to the kidneys. Again the AortaFit™ System was used to quickly determine the location of 3 fenestrations and to guide modification of a standard Bolton Medical endograft, enabling the patient to be treated endovascularly while increasing the effective seal zone from 2mm to 35.3mm.”
stats Advertisement
DOTmed text ad

Training and education based on your needs

Stay up to date with the latest training to fix, troubleshoot, and maintain your critical care devices. GE HealthCare offers multiple training formats to empower teams and expand knowledge, saving you time and money

stats

You Must Be Logged In To Post A Comment