There are over
27,000 listings on
DOTmed.com on
any given day.
THIS WEEK'S STAR ATTRACTIONS:

Ad Statistics
Times Displayed: 113248
Times Visited: 6741 MIT labs, experts in Multi-Vendor component level repair of: MRI Coils, RF amplifiers, Gradient Amplifiers Contrast Media Injectors. System repairs, sub-assembly repairs, component level repairs, refurbish/calibrate. info@mitlabsusa.com/+1 (305) 470-8013
No. 4279 : TOSHIBA Excelart AG MRI Scanner
You are bidding on a Toshiba Excelart / AG 1.5T MRI Scanner.
Installed May, 2002
Configuration:
Actively Shielded Short-Bore Magnet
Excelart / AG Base System
Heat Exchanger
Sony Optical Platter
TIM Image Maker Kit
COILS:
Breast Coil
Qd Knee Coil
Shoulder Array Coil
Flexible Body Array Coil
GP Flex Coil
Circular Coil Set
Bilateral TMJ Coil
QD Neurovascular Array Coil
PIANISSIMO Plus Imaging Pack
4 Channel Array Adapter
DICOM Basic License Kit
DICOM Storage SCU Kit
DICOM Print SCU Kit
DICOM Query/Retrieve SCP Kit
DICOM MWM SCU Kit
2 Channel Array Adapter
Cardiac Gating Unit
Cardiac 2001 Package
I/F Analog Interface
Respiratory Gating Package
MRA2001 Package
EPI2001 Package
Peripheral Gating Package
No. 4073 : CADOLTO Operating Theatre Modular Building
You are bidding on a fully fitted modular operating theatre with 8 bed recovery ward although this could be reconfigured to incorporate two theatres.
The building has a life anticipated to be in excess of 30 years.
Due to its modular construction it can be adapted to fit a hospital or can be used as a standalone clinic.
It can moved and installed in a matter of weeks.
This is an amazing opportunity to own an entire suite at a drastically reduced price.
The building has a 30 year plus expected life and it was originally supplied in November 2003 so it is only 4 years old.
The theatre is equipped with operating lights and laminar flow, used for orthopedic surgery and has an ultra clean canopy.
The laminar flow is McLeod Russel Lambda CG-US. We have a technical specification if needed.
The lights are a Draeger Sola Operating Theatre lamp.
The surgeon's panel was supplied by Starksrom.
No. 4140 : GE 1.0 Signa Advantage MRI Mobile
-System installed in a 1995 Calumet Coach Trailer
-System ID# 608836
-Has Gradient amplitude of 10mT/m
-Software Level 5.8 with Interactive Vascular Package, TOF Vascular, Intergrated Software Package, Multi Slice/Multi Angle and Stealth Feature
Coils:
Body
Quad Head
Posterior Neck
Anterior Neck
Quad T/L
Shoulder
Quad Knee
Foot/Ankle
GP Flex
3" Round
All operations manuals, software (with software owner/lessor approval) and service records available at the time of inspection are to be included with the system purchase.